RESULTS OF A MULTISITE ROUND-ROBIN TO EXAMINE PROBED MEASUREMENTS OF AN IMPEDANCE STANDARD SUBSTRATE

被引:1
|
作者
RAGGIO, J
机构
[1] TRW Electronic Systems Group, Redondo Beach
关键词
D O I
10.1109/19.65806
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The results from a round-robin measurement using microwave coplanar waveguide probes are presented. The round-robin was initiated and coordinated by the TRW Equipment Management Center's Measurement Engineering Department (MED). Ten probe sites, within and outside of TRW, participated in the round-robin. Each participant used the same Cascade Microtech Impedance Standard Substrate, the same measurement and calibration structures, the same calibration method, and the same network analyzer conditions. S-parameter measurements were performed over the frequency range of 0.045-26.5 GHz on a 10-dB attenuator and a 20-dB attenuator. In addition to the data comparison between the various probe sites, measurement repeatability results obtained within the TRW Measurement Engineering Department will be presented. © 1990 IEEE
引用
收藏
页码:962 / 963
页数:2
相关论文
共 50 条
  • [31] EUSTAS Protocol and Round-Robin testing of steviol glycosides by an internal standard method
    Geuns, Jan M. C.
    Struyf, Tom
    Bartholomees, Uria
    Ceunen, Stijn
    STEVIA: SIX MONTHS BEYOND AUTHORIZATION, 2012, : 117 - 142
  • [32] Initial results of the bidirectional reflectance characterization round-robin in support of EOS
    Johnson, BC
    Barnes, PY
    O'Brian, TR
    Butler, JJ
    Bruegge, CJ
    Biggar, S
    Spyak, PR
    Pavlov, MM
    METROLOGIA, 1998, 35 (04) : 609 - 613
  • [33] Toxoplasmosis round-robin test in Austria:: results and limits of the toxoplasmosis screening
    Auer, H
    Vander-Möse, A
    Picher, O
    Aspöck, H
    WIENER KLINISCHE WOCHENSCHRIFT, 2005, 117 : 20 - 28
  • [34] Round-robin studies of two potential seebeck coefficient standard reference materials
    Lowhorn, Nathan D.
    Wong-Ng, W.
    Zhang, W.
    Lu, Z. Q.
    Otani, M.
    Thomas, E.
    Green, M.
    Tran, T. N.
    Dilley, N.
    Elsner, N.
    Hogan, T.
    Li, Q.
    Obara, H.
    Sharp, J.
    Venkatasubramanian, R.
    Willigan, R.
    Yang, J.
    Nolas, G.
    Tritt, T.
    PROCEEDINGS ICT 07: TWENTY-SIXTH INTERNATIONAL CONFERENCE ON THERMOELECTRICS, 2008, : 366 - 370
  • [35] ASSESSMENT OF ERRORS FROM ROUND-ROBIN RESULTS FOR THE DETERMINATION OF NITROGEN IN STEELS
    ZITTER, H
    GOD, C
    PITNER, P
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (01): : 29 - 36
  • [36] The Cox/Merz-relation revisited: Results of a round-robin test
    Gahleitner, M
    XIITH INTERNATIONAL CONGRESS ON RHEOLOGY, PROCEEDINGS, 1996, : 70 - 71
  • [37] ROUND-ROBIN ATOM-PROBE EXPERIMENT - PRELIMINARY-RESULTS
    MELMED, AJ
    CARROLL, JJ
    BRENNER, SS
    ULTRAMICROSCOPY, 1979, 4 (03) : 386 - 386
  • [38] COMPARISON OF OUTDOOR AND ACCELERATED EXPOSURE METHODS - RESULTS OF A ROUND-ROBIN TEST
    不详
    JOURNAL OF COATINGS TECHNOLOGY, 1986, 58 (734): : 57 - 65
  • [39] THE PRESENTATION OF RESULTS FROM ROUND-ROBIN TEST-BLOCK TRIALS
    TEMPLE, JAG
    STRINGFELLOW, MW
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 1987, 27 (01) : 49 - 89
  • [40] THE RESULTS OF A ROUND-ROBIN EXERCISE ON PRESSURE-VESSEL DEFECT ASSESSMENT
    HOPKINS, P
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 1990, 42 (03) : 333 - 351