Three-dimensional MP-RAGE - An alternative to conventional three-dimensional FLASH sequences for the diagnosis of viscerocranial tumours?

被引:8
|
作者
Held, P [1 ]
Fellner, C [1 ]
Fellner, F [1 ]
Geissler, A [1 ]
Gmeinwieser, J [1 ]
机构
[1] KLINIKUM INGOLSTADT,STRAHLENDIAGNOST ABT,D-85049 INGOLSTADT,GERMANY
来源
BRITISH JOURNAL OF RADIOLOGY | 1995年 / 68卷 / 816期
关键词
D O I
10.1259/0007-1285-68-816-1316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Imaging with three-dimensional (3D) sequences is a frequently used magnetic resonance (MR) technique in the assessment of ear, nose and throat (ENT) tumours near the skull base. Few reports on the contrast behaviour of 3D magnetization prepared rapid gradient echo (MP-RAGE) sequences and their application in ENT tumours exist in the published literature. This paper discusses whether 3D MP-RAGE is an alternative to conventional 3D gradient echo (3D GE) sequences for the diagnostic evaluation of the visceral cranium. Measurements were performed with a Magnetom SP 63 MR system (Siemens) at 1.5 T. 10 healthy volunteers were examined using 3D FLASH sequences with varied flip angles (90 degrees, 70 degrees, 40 degrees, 20 degrees, 10 degrees) and using 3D MP-RAGE to optimize the signal-to-noise ratio (SNR) of muscle, fat and gland tissue. After this optimization 25 patients with ENT tumours near the skull base were examined with 3D FLASH 40 degrees, 3D MP-RAGE 10 degrees (both before and after application of contrast medium) and with 3D FISP 70 degrees (without contrast medium). SNR and contrast-to-noise ratio (CNR) of tumour, inflammatory disease, brain (white and grey matter), compact bone, fat and muscle were calculated. The advantages of 3D MP-RAGE over 3D FLASH 40 degrees include decreased imaging time with decreased motion artifacts and a relatively high contrast between tumour and surrounding tissues. The tissue contrast yielded by the T-1/T-2* weighted 3D gradient echo sequence FISP with a flip angle of 70 degrees was not as good as that yielded by 3D MP-RAGE with and without contrast together. In conclusion a combination of contrast enhanced and unenhanced 3D MP-RAGE sequences is the technique of choice for the examination of ENT tumours near the base of the skull.
引用
收藏
页码:1316 / 1324
页数:9
相关论文
共 50 条
  • [41] Three-dimensional sprites for lenticular-type three-dimensional display
    Dairiki, Takeshi
    Takaki, Yasuhiro
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XIII, 2006, 6055
  • [43] Three-Dimensional Measurement and Three-Dimensional Printing of Giant Coastal Rocks
    Gao, Zhiyi
    Doi, Akio
    Sakakibara, Kenji
    Hosokawa, Tomonaru
    Harata, Masahiro
    ISPRS INTERNATIONAL JOURNAL OF GEO-INFORMATION, 2021, 10 (06)
  • [44] Overview and Outlook of Three-Dimensional Integrated Circuit Packaging, Three-Dimensional Si Integration, and Three-Dimensional Integrated Circuit Integration
    Lau, John H.
    JOURNAL OF ELECTRONIC PACKAGING, 2014, 136 (04)
  • [45] Three-dimensional ultrasound diagnosis of interstitial pregnancy
    Lawrence, A
    Jurkovic, D
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1999, 14 (04) : 292 - 293
  • [46] Three-dimensional ultrasonography in the diagnosis of deep endometriosis
    Guerriero, Stefano
    Saba, Luca
    Ajossa, Silvia
    Peddes, Cristina
    Angiolucci, Marco
    Perniciano, Maura
    Melis, Gian Benedetto
    Luis Alcazar, Juan
    HUMAN REPRODUCTION, 2014, 29 (06) : 1189 - 1198
  • [47] Three-dimensional transvaginal ultrasound in gynecological diagnosis
    Merz, E
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1999, 14 (02) : 81 - 86
  • [48] Three-dimensional sonographic diagnosis of ovarian pregnancy
    Ghi, T
    Banfi, A
    Marconi, R
    Iaco, PDE
    Pilu, G
    Aloysio, DDE
    Pelusi, G
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 26 (01) : 102 - 104
  • [49] Three-dimensional ultrasound - a requirement for prenatal diagnosis?
    Merz, E
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 12 (04) : 225 - 226
  • [50] Three-dimensional ultrasound
    Nelson, TR
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 51 - 52