Three-dimensional MP-RAGE - An alternative to conventional three-dimensional FLASH sequences for the diagnosis of viscerocranial tumours?

被引:8
|
作者
Held, P [1 ]
Fellner, C [1 ]
Fellner, F [1 ]
Geissler, A [1 ]
Gmeinwieser, J [1 ]
机构
[1] KLINIKUM INGOLSTADT,STRAHLENDIAGNOST ABT,D-85049 INGOLSTADT,GERMANY
来源
BRITISH JOURNAL OF RADIOLOGY | 1995年 / 68卷 / 816期
关键词
D O I
10.1259/0007-1285-68-816-1316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Imaging with three-dimensional (3D) sequences is a frequently used magnetic resonance (MR) technique in the assessment of ear, nose and throat (ENT) tumours near the skull base. Few reports on the contrast behaviour of 3D magnetization prepared rapid gradient echo (MP-RAGE) sequences and their application in ENT tumours exist in the published literature. This paper discusses whether 3D MP-RAGE is an alternative to conventional 3D gradient echo (3D GE) sequences for the diagnostic evaluation of the visceral cranium. Measurements were performed with a Magnetom SP 63 MR system (Siemens) at 1.5 T. 10 healthy volunteers were examined using 3D FLASH sequences with varied flip angles (90 degrees, 70 degrees, 40 degrees, 20 degrees, 10 degrees) and using 3D MP-RAGE to optimize the signal-to-noise ratio (SNR) of muscle, fat and gland tissue. After this optimization 25 patients with ENT tumours near the skull base were examined with 3D FLASH 40 degrees, 3D MP-RAGE 10 degrees (both before and after application of contrast medium) and with 3D FISP 70 degrees (without contrast medium). SNR and contrast-to-noise ratio (CNR) of tumour, inflammatory disease, brain (white and grey matter), compact bone, fat and muscle were calculated. The advantages of 3D MP-RAGE over 3D FLASH 40 degrees include decreased imaging time with decreased motion artifacts and a relatively high contrast between tumour and surrounding tissues. The tissue contrast yielded by the T-1/T-2* weighted 3D gradient echo sequence FISP with a flip angle of 70 degrees was not as good as that yielded by 3D MP-RAGE with and without contrast together. In conclusion a combination of contrast enhanced and unenhanced 3D MP-RAGE sequences is the technique of choice for the examination of ENT tumours near the base of the skull.
引用
收藏
页码:1316 / 1324
页数:9
相关论文
共 50 条
  • [31] Contribution of three-dimensional ultrasound and three-dimensional helical computed tomography to prenatal diagnosis of Stickler syndrome
    Gueneuc, A.
    Spaggiari, E.
    Millischer, A. E.
    Michot, C.
    O'Gorman, N.
    Ville, Y.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 54 (02) : 279 - +
  • [32] Variability of three-dimensional ultrasonography for assessment of intraocular tumours
    Maberley, D
    Fisher, Y
    Carvahlo, C
    Goldbaum, M
    Raboud, J
    Shields, JA
    Chang, S
    Yannuzzi, LA
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2002, 37 (05): : 283 - 289
  • [33] Three-dimensional effects created by macromedia flash MX
    Liu, J
    Lawhead, P
    CISST'03: PROCEEDING OF THE INTERNATIONAL CONFERENCE ON IMAGING SCIENCE, SYSTEMS AND TECHNOLOGY, VOLS 1 AND 2, 2003, : 331 - 334
  • [34] Three-dimensional Image Sensor with MPPC for Flash LIDAR
    Mizuno, Takahide
    Ikeda, Hirokazu
    Nagano, Terumasa
    Baba, Takashi
    Mita, Makoto
    Mimasu, Yuya
    Hoshino, Takeshi
    TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, 2020, 63 (02) : 42 - 49
  • [35] Analysis and interpretation of three-dimensional lightning flash information
    Murphy, MJ
    Cummins, KL
    Maier, LM
    16TH INTERNATIONAL CONFERENCE ON INTERACTIVE INFORMATION AND PROCESSING SYSTEMS (IIPS) FOR METEOROLOGY, OCEANOGRAPHY AND HYDROLOGY, 2000, : 102 - 105
  • [36] Three-dimensional stress analysis by three-dimensional local hybrid method
    Machida, K
    FRACTURE AND STRENGTH OF SOLIDS VI, PTS 1 AND 2, 2006, 306-308 : 523 - 528
  • [37] Three-dimensional printing and three-dimensional aligner-A success story
    Ludhwani, Suresh
    JOURNAL OF THE INTERNATIONAL CLINICAL DENTAL RESEARCH ORGANIZATION, 2022, 14 (02) : 81 - 82
  • [38] Three-dimensional optical data storage using three-dimensional optics
    Kawata, Y
    Nakano, M
    Lee, SC
    OPTICAL ENGINEERING, 2001, 40 (10) : 2247 - 2254
  • [39] THREE-DIMENSIONAL CORONAL SLOW MODES: TOWARD THREE-DIMENSIONAL SEISMOLOGY
    Marsh, M. S.
    Walsh, R. W.
    Plunkett, S.
    ASTROPHYSICAL JOURNAL, 2009, 697 (02): : 1674 - 1680
  • [40] Three-Dimensional Materials Science: An Intersection of Three-Dimensional Reconstructions and Simulations
    Katsuyo Thornton
    Henning Friis Poulsen
    MRS Bulletin, 2008, 33 : 587 - 595