摘要
Imaging with three-dimensional (3D) sequences is a frequently used magnetic resonance (MR) technique in the assessment of ear, nose and throat (ENT) tumours near the skull base. Few reports on the contrast behaviour of 3D magnetization prepared rapid gradient echo (MP-RAGE) sequences and their application in ENT tumours exist in the published literature. This paper discusses whether 3D MP-RAGE is an alternative to conventional 3D gradient echo (3D GE) sequences for the diagnostic evaluation of the visceral cranium. Measurements were performed with a Magnetom SP 63 MR system (Siemens) at 1.5 T. 10 healthy volunteers were examined using 3D FLASH sequences with varied flip angles (90 degrees, 70 degrees, 40 degrees, 20 degrees, 10 degrees) and using 3D MP-RAGE to optimize the signal-to-noise ratio (SNR) of muscle, fat and gland tissue. After this optimization 25 patients with ENT tumours near the skull base were examined with 3D FLASH 40 degrees, 3D MP-RAGE 10 degrees (both before and after application of contrast medium) and with 3D FISP 70 degrees (without contrast medium). SNR and contrast-to-noise ratio (CNR) of tumour, inflammatory disease, brain (white and grey matter), compact bone, fat and muscle were calculated. The advantages of 3D MP-RAGE over 3D FLASH 40 degrees include decreased imaging time with decreased motion artifacts and a relatively high contrast between tumour and surrounding tissues. The tissue contrast yielded by the T-1/T-2* weighted 3D gradient echo sequence FISP with a flip angle of 70 degrees was not as good as that yielded by 3D MP-RAGE with and without contrast together. In conclusion a combination of contrast enhanced and unenhanced 3D MP-RAGE sequences is the technique of choice for the examination of ENT tumours near the base of the skull.
引用
收藏
页码:1316 / 1324
页数:9
相关论文
共 50 条
  • [1] Diffusion-weighted three-dimensional MP-RAGE MR imaging
    Numano, T
    Homma, K
    Hirose, T
    MAGNETIC RESONANCE IMAGING, 2005, 23 (03) : 463 - 468
  • [2] Reliability of interactive three-dimensional brain volumetry using MP-RAGE magnetic resonance imaging
    Julin, P
    Melin, T
    Andersen, C
    Isberg, B
    Svensson, L
    Wahlund, LO
    PSYCHIATRY RESEARCH-NEUROIMAGING, 1997, 76 (01) : 41 - 49
  • [3] A T1-weighted rapid three-dimensional gradient-echo technique (MP-RAGE) in preoperative MRI of intracranial tumours
    Fellner, F
    Holl, K
    Held, P
    Fellner, C
    Schmitt, R
    BohmJurkovic, H
    NEURORADIOLOGY, 1996, 38 (03) : 199 - 206
  • [4] Three-dimensional AND flash memory
    Kim, Y.
    Park, I. H.
    Kwon, H. T.
    Wee, D.
    Park, B. -G.
    ELECTRONICS LETTERS, 2017, 53 (11) : 743 - 744
  • [5] Three-dimensional MRI sequences in MS diagnosis and research
    Hu, Xun Yang
    Rajendran, Luckshi
    Lapointe, Emmanuelle
    Tam, Roger
    Li, David
    Traboulsee, Anthony
    Rauscher, Alexander
    MULTIPLE SCLEROSIS JOURNAL, 2019, 25 (13) : 1700 - 1709
  • [6] Fat-saturated diffusion-weighted imaging of the rat pelvis using three-dimensional MP-RAGE MR sequence
    Numano, T.
    Homma, K.
    Iwasaki, N.
    Hyodo, K.
    Nitta, N.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2038 - 2041
  • [7] Three-dimensional diffusion weighted imaging of the acute cerebral ischemia rat using 3D MP-RAGE MRI
    Numano, T.
    Marushima, A.
    Hyodo, K.
    Homma, K.
    Suzuki, K.
    Matsumura, A.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3179 - 3182
  • [8] Three-dimensional modes of three-dimensional microlasers
    Sobeshchuk, N.
    Guidry, M.
    Bittner, S.
    Decanini, D.
    Baron, O.
    Scheuer, J.
    Zyss, J.
    Lebental, M.
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2017,
  • [9] Three-dimensional diffuser and three-dimensional speckles
    A. P. Vladimirov
    Technical Physics, 1998, 43 : 1454 - 1458
  • [10] Three-dimensional diffuser and three-dimensional speckles
    Vladimirov, AP
    TECHNICAL PHYSICS, 1998, 43 (12) : 1454 - 1458