Hemodynamics and tolerability of lower-limb intermittent pneumatic compression devices and neuromuscular stimulation

被引:6
|
作者
Praxitelous, Praxitelis [1 ,2 ]
Edman, Gunnar [2 ,3 ]
Ackermann, Paul W. [1 ,2 ]
机构
[1] Karolinska Inst, Dept Mol Med & Surg, Integrat Orthoped Lab, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Orthoped, Stockholm, Sweden
[3] Tiohundra AB, Dept Psychiat, Norrtalje, Sweden
关键词
blood flow velocity; electric stimulation therapy; pneumatic devices;
D O I
10.1002/tsm2.32
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Stimulation of venous return is critical for prevention of venous thromboembolism; however, an optimized treatment modality has yet to be defined. Therefore, the main objective of this study was to investigate and compare the hemodynamic effects and the second aim was to assess tolerability of three different intermittent pneumatic compression (IPC) devices, foot-IPC, rapid, and slow calf-IPC, and the recently developed technology of calf neuromuscular electric stimulation (NMES). The blood flow in the right popliteal vein was assessed with Doppler ultrasound in 10 healthy individuals in semirecumbent position without (baseline) and with each of the IPC- and NMES treatment devices. Comfort assessment was completed using visual analogue scale for each treatment modality. All treatments significantly increased peak velocity (PV), mean velocity (MV) volume flow (VF) and ejected volume per individual stimulus (EV) as compared to baseline. Rapid calf-IPC caused the most profound hemodynamic effects with a mean effect size 2.06, taking into account all the above hemodynamic parameters compared to baseline. The weakest response was observed with foot-IPC with a mean effect size 1.50 compared to baseline. All devices compressing the calf produced higher hemodynamic values (mean effect size: 1.89 slow calf-IPC and 1.58 NMES) compared to foot-IPC. Comfort assessment demonstrated unacceptable tolerability for NMES, while the other devices showed an acceptable tolerability. Augmentation of venous return using calf- compared to foot devices is hemodynamically superior. Varying hemodynamic responses are observed between calf blood flow stimulating devices. The low tolerability of NMES, however, may limit its clinical applicability.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [41] Neuromuscular Response To Seven Days Unilateral Lower-limb Immobilization
    Brooks, Naomi E.
    Kay, Katerina
    Weir, Mairi
    Hunter, Angus M.
    Macgregor, Lewis J.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 221 - 221
  • [42] Employing Deep Reinforcement Learning to Maximize Lower Limb Blood Flow Using Intermittent Pneumatic Compression
    Santelices, Iara B.
    Landry, Cederick
    Arami, Arash
    Peterson, Sean D.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (10) : 6193 - 6200
  • [43] Metabolic and Structural Changes in Lower-Limb Skeletal Muscle Following Neuromuscular Electrical Stimulation: A Systematic Review
    Sillen, Maurice J. H.
    Franssen, Frits M. E.
    Gosker, Harry R.
    Wouters, Emiel F. M.
    Spruit, Martijn A.
    PLOS ONE, 2013, 8 (09):
  • [44] ELECTRICAL AND MAGNETIC STIMULATION OF LOWER-LIMB NERVES AND ROOTS
    SMITH, SJM
    MURRAY, NMF
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1987, 67 (05): : P92 - P93
  • [45] ELECTRICAL AND MAGNETIC STIMULATION OF LOWER-LIMB NERVES AND ROOTS
    SMITH, SJM
    MURRAY, NMF
    MUSCLE & NERVE, 1986, 9 (07) : 652 - 653
  • [46] Lower-Limb Orthoses Combined with Functional Electrical Stimulation
    de Souza, D. C.
    Nogueira-Neto, G. N.
    Nohama, P.
    5TH ISSNIP-IEEE BIOSIGNALS AND BIOROBOTICS CONFERENCE (2014): BIOSIGNALS AND ROBOTICS FOR BETTER AND SAFER LIVING, 2014, : 80 - 83
  • [48] EVALUATION OF INTERMITTENT PNEUMATIC COMPRESSION DEVICES IN ACUTE STROKE PATIENTS
    Meilak, C.
    Whittle, A.
    MacKey, T.
    Oyemade, L.
    Battle, L.
    Patel, M.
    AGE AND AGEING, 2017, 46
  • [49] Comparing patient tolerance of lower limb intermittent compression devices following major orthopaedic surgery
    Gilmartin, S.
    Ramasamy, A.
    Gaine, W.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 55 - 55
  • [50] INVESTIGATION OF THE VENOUS HEMODYNAMICS OF THE LOWER-LIMB BY VENOUS-PRESSURE MODELS
    PSATHAKIS, ND
    PSATHAKIS, DN
    ANGIOLOGY, 1986, 37 (07) : 499 - 507