Hemodynamics and tolerability of lower-limb intermittent pneumatic compression devices and neuromuscular stimulation

被引:6
|
作者
Praxitelous, Praxitelis [1 ,2 ]
Edman, Gunnar [2 ,3 ]
Ackermann, Paul W. [1 ,2 ]
机构
[1] Karolinska Inst, Dept Mol Med & Surg, Integrat Orthoped Lab, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Orthoped, Stockholm, Sweden
[3] Tiohundra AB, Dept Psychiat, Norrtalje, Sweden
关键词
blood flow velocity; electric stimulation therapy; pneumatic devices;
D O I
10.1002/tsm2.32
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Stimulation of venous return is critical for prevention of venous thromboembolism; however, an optimized treatment modality has yet to be defined. Therefore, the main objective of this study was to investigate and compare the hemodynamic effects and the second aim was to assess tolerability of three different intermittent pneumatic compression (IPC) devices, foot-IPC, rapid, and slow calf-IPC, and the recently developed technology of calf neuromuscular electric stimulation (NMES). The blood flow in the right popliteal vein was assessed with Doppler ultrasound in 10 healthy individuals in semirecumbent position without (baseline) and with each of the IPC- and NMES treatment devices. Comfort assessment was completed using visual analogue scale for each treatment modality. All treatments significantly increased peak velocity (PV), mean velocity (MV) volume flow (VF) and ejected volume per individual stimulus (EV) as compared to baseline. Rapid calf-IPC caused the most profound hemodynamic effects with a mean effect size 2.06, taking into account all the above hemodynamic parameters compared to baseline. The weakest response was observed with foot-IPC with a mean effect size 1.50 compared to baseline. All devices compressing the calf produced higher hemodynamic values (mean effect size: 1.89 slow calf-IPC and 1.58 NMES) compared to foot-IPC. Comfort assessment demonstrated unacceptable tolerability for NMES, while the other devices showed an acceptable tolerability. Augmentation of venous return using calf- compared to foot devices is hemodynamically superior. Varying hemodynamic responses are observed between calf blood flow stimulating devices. The low tolerability of NMES, however, may limit its clinical applicability.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [31] Intermittent pneumatic compression therapy for critical limb ischemia
    Rooke, TW
    ADVANCES IN VASCULAR SURGERY, 2002, : 15 - 23
  • [32] Effects of Electromyographically-driven Neuromuscular Stimulation Cycling System on the Lower-Limb of Stroke Survivors
    Au, Cheuk-Yan
    Mehra, Prabhav
    Leung, Kenry W. C.
    Tong, Raymond K. Y.
    2019 IEEE 16TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2019, : 300 - 304
  • [33] On the implementation and control of a pneumatic power active lower-limb orthosis
    Huang, Chia-En
    Chen, Jian-Shiang
    MECHATRONICS, 2013, 23 (05) : 505 - 517
  • [34] Intermittent pneumatic compression devices - Physiological mechanisms of action
    Chen, AH
    Frangos, SG
    Kilaru, S
    Sumpio, BE
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 21 (05) : 383 - 392
  • [35] Intermittent pneumatic compression devices: time to reassess the evidence
    Lott, Natalie
    Smith, Stephen
    Gani, Jonathan
    Reeves, Penny
    ANZ JOURNAL OF SURGERY, 2023, 93 (04) : 812 - 814
  • [36] LOWER-LIMB HEMODYNAMICS DURING ANTIHYPERTENSIVE TREATMENT WITH METOPROLOL AND PROPRANOLOL
    LEPANTALO, MJA
    TOTTERMAN, KJ
    INTERNATIONAL ANGIOLOGY, 1985, 4 (02) : 225 - 228
  • [37] LOWER-LIMB VENOUS HEMODYNAMICS DURING LAPAROSCOPY - AN ANIMAL STUDY
    JORGENSEN, JO
    GILLIES, RB
    LALAK, NJ
    HUNT, DR
    SURGICAL LAPAROSCOPY & ENDOSCOPY, 1994, 4 (01) : 32 - 35
  • [38] Comparison of the Hemodynamic Performance of Two Neuromuscular Electrical Stimulation Devices Applied to the Lower Limb
    Avazzadeh, Sahar
    O'Farrell, Andrea
    Flaherty, Kate
    O'Connell, Sandra
    OLaighin, Gearoid
    Quinlan, Leo R.
    JOURNAL OF PERSONALIZED MEDICINE, 2020, 10 (02):
  • [39] A systematic review of intermittent pneumatic compression for critical limb ischaemia
    Moran, Patrick S.
    Teljeur, Conor
    Harrington, Patricia
    Ryan, Mairin
    VASCULAR MEDICINE, 2015, 20 (01) : 41 - 50
  • [40] Critical limb ischemia successfully treated by intermittent pneumatic compression
    Moses, Y
    Yoffe, B
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2002, 4 (09): : 728 - 729