NORMAL ROTATOR CUFF - MR IMAGING WITH CONVENTIONAL AND FAT-SUPPRESSION TECHNIQUES

被引:75
|
作者
MIROWITZ, SA
机构
[1] Department of Radiology, Jewish Hospital, Washington Univ. Medical Ctr., St Louis, MO 63110
关键词
MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; MAGNETIC RESONANCE (MR) TISSUE CHARACTERIZATION; SHOULDER; ANATOMY; MR STUDIES;
D O I
10.1148/radiology.180.3.1871287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The signal intensity and morphologic characteristics of the rotator cuff and surrounding structures at magnetic resonance (MR) imaging were investigated with five pulse sequences in 15 asymptomatic subjects. In all subjects, a focal region of relative increased signal intensity corresponding to the critical zone was observed in the supraspinatus tendon just proximal to its insertion. Soft-tissue signal intensity (isointense with muscle) was also located between the supraspinatus tendon and underlying joint capsule, interposed between the conjoined leaves of the supraspinatus and infraspinatus tendons, and superolateral to the conjoined cuff tendon, near its insertion. These regions were most conspicuous and most clearly defined with fat-suppression imaging. Small amounts of fluid were observed within the joint space and its recesses, the bicipital tendon sheath, and the subacromial-subdeltoid bursa. These and other MR imaging findings of this study previously have been regarded as indicative of rotator cuff abnormalities. These results will help refine the criteria for diagnosis of rotator cuff disorders with MR imaging.
引用
收藏
页码:735 / 740
页数:6
相关论文
共 50 条
  • [31] PHASE UNWRAPPING IN THE 3-POINT DIXON METHOD FOR FAT-SUPPRESSION MR-IMAGING
    SZUMOWSKI, J
    COSHOW, WR
    LI, F
    QUINN, SF
    RADIOLOGY, 1994, 192 (02) : 555 - 561
  • [32] Value of fat-suppression gradient-echo MR imaging in the diagnosis of ovarian cystic teratomas
    Bazot, M
    Boudghène, F
    Billières, P
    Antoine, JM
    Uzan, S
    Bigot, JM
    CLINICAL IMAGING, 2000, 24 (03) : 146 - 153
  • [33] MR IMAGING OF OPTIC-NERVE LESIONS - VALUE OF GADOPENTETATE DIMEGLUMINE AND FAT-SUPPRESSION TECHNIQUE
    HENDRIX, LE
    KNEELAND, JB
    HAUGHTON, VM
    DANIELS, DL
    SZUMOWSKI, J
    WILLIAMS, AL
    MARK, LP
    CZERVIONKE, LF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1990, 11 (04) : 749 - 754
  • [34] MR IMAGING OF OPTIC-NERVE LESIONS - VALUE OF GADOPENTETATE DIMEGLUMINE AND FAT-SUPPRESSION TECHNIQUE
    HENDRIX, LE
    KNEELAND, JB
    HAUGHTON, VM
    DANIELS, DL
    SZUMOWSKI, J
    WILLIAMS, AL
    MARK, LP
    CZERVIONKE, LF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) : 849 - 854
  • [35] HIGH-INTENSITY SIGNALS WITHIN THE POSTERIOR PITUITARY FOSSA - A STUDY WITH FAT-SUPPRESSION MR TECHNIQUES
    MARK, LP
    HAUGHTON, VM
    HENDRIX, LE
    DANIELS, DL
    WILLIAMS, AL
    CZERVIONKE, LF
    ASLESON, RJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (03) : 529 - 532
  • [36] HIGH-INTENSITY SIGNALS WITHIN THE POSTERIOR PITUITARY FOSSA - A STUDY WITH FAT-SUPPRESSION MR TECHNIQUES
    MARK, LP
    HAUGHTON, VM
    HENDRIX, LE
    DANIELS, DL
    WILLIAMS, AL
    CZERVIONKE, LF
    ASLESON, RJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (02) : 389 - 392
  • [37] MR arthrography in the diagnosis of rotator cuff tears - Standard spin-echo alone or with fat suppression?
    Funke, M
    Kopka, L
    Vosshenrich, R
    Oestmann, JW
    Grabbe, E
    ACTA RADIOLOGICA, 1996, 37 (05) : 627 - 632
  • [38] ROTATOR CUFF - EVALUATION WITH FAT-SUPPRESSED MR ARTHROGRAPHY
    PALMER, WE
    BROWN, JH
    ROSENTHAL, DI
    RADIOLOGY, 1993, 188 (03) : 683 - 687
  • [39] MR imaging of delamination tears of the rotator cuff tendons
    Daniel M. Walz
    Theodore T. Miller
    Steven Chen
    Josh Hofman
    Skeletal Radiology, 2007, 36 : 411 - 416
  • [40] ROTATOR CUFF LESIONS - SIGNAL PATTERNS AT MR IMAGING
    RAFII, M
    FIROOZNIA, H
    SHERMAN, O
    MINKOFF, J
    WEINREB, J
    GOLIMBU, C
    GIDUMAL, R
    SCHINELLA, R
    ZASLAV, K
    RADIOLOGY, 1990, 177 (03) : 817 - 823