NORMAL ROTATOR CUFF - MR IMAGING WITH CONVENTIONAL AND FAT-SUPPRESSION TECHNIQUES

被引:75
|
作者
MIROWITZ, SA
机构
[1] Department of Radiology, Jewish Hospital, Washington Univ. Medical Ctr., St Louis, MO 63110
关键词
MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; MAGNETIC RESONANCE (MR) TISSUE CHARACTERIZATION; SHOULDER; ANATOMY; MR STUDIES;
D O I
10.1148/radiology.180.3.1871287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The signal intensity and morphologic characteristics of the rotator cuff and surrounding structures at magnetic resonance (MR) imaging were investigated with five pulse sequences in 15 asymptomatic subjects. In all subjects, a focal region of relative increased signal intensity corresponding to the critical zone was observed in the supraspinatus tendon just proximal to its insertion. Soft-tissue signal intensity (isointense with muscle) was also located between the supraspinatus tendon and underlying joint capsule, interposed between the conjoined leaves of the supraspinatus and infraspinatus tendons, and superolateral to the conjoined cuff tendon, near its insertion. These regions were most conspicuous and most clearly defined with fat-suppression imaging. Small amounts of fluid were observed within the joint space and its recesses, the bicipital tendon sheath, and the subacromial-subdeltoid bursa. These and other MR imaging findings of this study previously have been regarded as indicative of rotator cuff abnormalities. These results will help refine the criteria for diagnosis of rotator cuff disorders with MR imaging.
引用
收藏
页码:735 / 740
页数:6
相关论文
共 50 条
  • [21] SMALL PANCREATIC ADENOCARCINOMAS - EFFICACY OF MR-IMAGING WITH FAT-SUPPRESSION AND GADOLINIUM ENHANCEMENT
    GABATA, T
    MATSUI, O
    KADOYA, M
    YOSHIKAWA, J
    MIYAYAMA, S
    TAKASHIMA, T
    NAGAKAWA, T
    KAYAHARA, M
    NONOMURA, A
    RADIOLOGY, 1994, 193 (03) : 683 - 688
  • [22] Evaluation of optimized inversion-recovery fat-suppression techniques for T2-weighted abdominal MR imaging
    Lauenstein, Thomas C.
    Sharma, Puneet
    Hughes, Timothy
    Heberlein, Keith
    Tudorascu, Dana
    Martin, Diego R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1448 - 1454
  • [23] WATER BAGS - AN INEXPENSIVE METHOD FOR IMPROVING FAT-SUPPRESSION IN MR-IMAGING OF THE EXTREMITIES
    SMITH, DK
    WRIGHT, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (05) : 1252 - 1253
  • [24] MN-DPDP-ENHANCED MR-IMAGING OF THE LIVER - VALUE OF FAT-SUPPRESSION AND DELAYED IMAGING
    MAHFOUZ, A
    COFFIN, C
    ZYLBERSZTEJN, C
    RAHMOUNI, A
    MATHIEU, DG
    VASILE, N
    RADIOLOGY, 1995, 197 : 176 - 177
  • [25] MR IMAGING ANATOMY OF THE SHOULDER ROTATOR CUFF
    TOTTERMAN, SM
    MILLER, RJ
    KWOK, E
    RADIOLOGY, 1992, 185 : 240 - 240
  • [26] MR IMAGING DIAGNOSIS OF ROTATOR CUFF TEARS
    EVANCHO, AM
    STILES, RG
    FAJMAN, WA
    FLOWER, SP
    MACHA, T
    BRUNNER, MC
    FLEMING, L
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) : 751 - 754
  • [27] ROTATOR CUFF IMPINGEMENT SYNDROME - MR IMAGING
    KIEFT, GJ
    BLOEM, JL
    ROZING, PM
    OBERMANN, WR
    RADIOLOGY, 1988, 166 (01) : 211 - 214
  • [28] MR imaging of the Mitek rotator cuff anchor
    Magee, TH
    Shapiro, MD
    Williams, DS
    RADIOLOGY, 2002, 225 : 422 - 422
  • [29] Rotator cuff: Evaluation with US and MR imaging
    Seibold, CJ
    Mallisee, TA
    Erickson, SJ
    Boynton, MD
    Raasch, WG
    Timins, ME
    RADIOGRAPHICS, 1999, 19 (03) : 685 - 705
  • [30] MR imaging of the rotator cuff with calcifying tendinitis
    Loew, M
    Sabo, D
    Mau, H
    Perlick, L
    Wehrle, M
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1996, 134 (04): : 354 - 359