EFFECT OF A VOLUMATIC SPACER AND MOUTH RINSING ON SYSTEMIC ABSORPTION OF INHALED CORTICOSTEROIDS FROM A METERED DOSE INHALER AND DRY POWDER INHALER

被引:109
|
作者
SELROOS, O [1 ]
HALME, M [1 ]
机构
[1] MJOLBOLSTA HOSP,SF-10350 MJOLBOLSTA,FINLAND
关键词
D O I
10.1136/thx.46.12.891
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background High doses of inhaled corticosteroids are absorbed systemically and may cause long term side effects. As rinsing the mouth out after use and inhaling through a spacing device may reduce systemic absorption this has been further investigated. Methods Three crossover studies were carried out to assess the effect of budesonide given by dry powder inhaler (Turbuhaler) with and without mouth rinsing and beclomethasone dipropionate given by metered dose inhaler with or without a spacing device (Volumatic) on serum cortisol concentrations and urinary cortisol excretion in patients with asthma taking an inhaled corticosteroid. Each treatment period was two weeks with a two week washout period. Serum cortisol concentrations at 0800 hours on day 14 and the 24 hour urinary excretion of cortisol were measured. In study 1 24 patients taking beclomethasone dipropionate 500-mu-g twice a day inhaled with (n = 10) or without (n = 14) a Volumatic spacing device were switched to a budesonide dry powder inhaler, 600-mu-g to be taken twice a day without mouth rinsing. In study 2 10 patients took budesonide 800-mu-g twice a day with and without mouth rinsing and without swallowing the rinsing water. In study 3 17 patients took budesonide 800-mu-g twice daily with mouth rinsing and beclomethasone dipropionate 500-mu-g twice daily with the spacing device and mouth rinsing. Results In study 1 no difference was seen between budesonide without mouth rinsing and beclomethasone dipropionate without a spacer: beclomethasone with spacer caused less suppression of cortisol (mean (SD) serum cortisol concentration: beclomethasone and spacer 487(148), budesonide 368(145) nmol/l). In study 2 mouth rinsing caused less suppression of morning serum cortisol concentrations (rinsing 440(63), no rinsing 375(56) nmol/1). In study 3 there was no difference in serum or urinary cortisol concentrations between twice daily beclomethasone dipropionate 500-mu-g inhaled by Volumatic spacer or budesonide by Turbuhaler 800-mu-g twice daily, both with mouth rinsing. Individual serum cortisol values were within the normal range in all patients except one in study 1. Conclusion Systemic absorption of a corticosteroid inhaled from a metered dose inhaler is reduced by using a spacing device and that from a dry powder inhaler by mouth rinsing.
引用
收藏
页码:891 / 894
页数:4
相关论文
共 50 条
  • [21] Effect of Flow Rate on Emitted Fine Particle Mass (FPM) from a Dry Powder Inhaler (DPI) and a Metered Dose Inhaler (MDI) with Spacer Delivering Salbutamol.
    Nagel, Mark
    Suggett, Jason
    Ali, Rubina
    Doyle, Cathy
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [22] A comparative study of efficacy of Salbutamol via metered dose inhaler (MDI) with volumatic Spacer and via dry powder inhaler (DPI), easyhaler, to nebulization in mild to moderate severity acute asthma exacerbation in children
    Sirikul, C.
    Chumpakdee, K.
    Vangveeravong, M.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (02) : S156 - S156
  • [23] Effect of inhalation flow rate on the dosing characteristics of dry powder inhaler (DPI) and metered dose inhaler (MDI) products
    Ross, DL
    Schultz, RK
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1996, 9 (02): : 215 - 226
  • [24] Pharmacokinetics of fluticasone propionate multidose, inhalation-driven, novel, dry powder inhaler versus a prevailing dry powder inhaler and a metered-dose inhaler
    Gillespie, Michael
    Song, Sharon
    Steinfeld, Jonathan
    ALLERGY AND ASTHMA PROCEEDINGS, 2015, 36 (05) : 365 - 371
  • [25] Therapeutic equivalence of spiros dry powder inhaler and ventolin metered dose inhaler - A bioassay using methacholine
    Ahrens, RC
    Hendeles, L
    Clarke, WR
    Dockhorn, RJ
    Hill, MR
    Vaughan, LM
    Lux, C
    Han, SH
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (04) : 1238 - 1243
  • [26] Comparison of salbutamol efficacy in children- via the metered-dose inhaler (MDI) with Volumatic® spacer and via the dry powder inhaler, Easyhaler®, with the nebulizer - in mild to moderate asthma exacerbation: a multicenter, randomized study
    Direkwatanachai, Chalerat
    Teeratakulpisarn, Jamaree
    Suntornlohanakul, Somchai
    Trakultivakorn, Muthita
    Ngamphaiboon, Jarungchit
    Wongpitoon, Nares
    Vangveeravong, Mukda
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2011, 29 (01): : 25 - 33
  • [27] COMPARISON OF TERBUTALINE AND PLACEBO FROM A PRESSURIZED METERED-DOSE INHALER AND A DRY POWDER INHALER IN A SUBGROUP OF PATIENTS WITH ASTHMA
    SELROOS, O
    LOFROOS, AB
    PIETINALHO, A
    RISKA, H
    THORAX, 1994, 49 (12) : 1228 - 1230
  • [28] A Preliminary Study of Inhaled Pharmaceutical Aerosol Flow Characteristics in Metered Dose Inhaler Spacer
    Salleh, A. F.
    Izham, M.
    Tasyrif, M.
    Yaacob, S.
    Helmy, K.
    4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 653 - +
  • [29] Comparison of the bronchodilating efficacies of a novel salbutamol metered dose powder inhaler and a pressurised metered dose aerosol with a spacer
    Seppälä, OP
    Kari, E
    Elo, J
    Löyttyniemi, E
    Kunkel, G
    ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 1998, 48 (09): : 919 - 923
  • [30] Formoterol inhaled as dry powder or via pressurized metered-dose inhaler in a cumulative dose-response study
    Ullman, A
    Lofdahl, CG
    Melander, B
    Svedmyr, N
    ALLERGY, 1996, 51 (10) : 745 - 748