Pharmacokinetics of fluticasone propionate multidose, inhalation-driven, novel, dry powder inhaler versus a prevailing dry powder inhaler and a metered-dose inhaler

被引:9
|
作者
Gillespie, Michael [1 ]
Song, Sharon [1 ]
Steinfeld, Jonathan [1 ]
机构
[1] Teva Pharmaceut, Teva Global Resp R&D, Frazer, PA 19355 USA
关键词
CAPSULE-BASED INHALER; POOR ASTHMA CONTROL; BECLOMETHASONE DIPROPIONATE; COMBINATION; DISKHALER(R); DISKUS(R); ADULTS;
D O I
10.2500/aap.2015.36.3889
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: A novel inhalation-driven multidose dry powder inhaler (MDPI) that eliminates the need for the patient to coordinate device actuation with inhalation has been developed for delivery of inhaled asthma medications. Objective: To characterize the pharmacokinetics of single-dose fluticasone propionate (Fp) MDPI compared with single doses of Fp dry powder inhaler (DPI) and a metered-dose inhaler (MDI) in healthy subjects. Methods: This was a single-center, open-label, randomized, three-period crossover, single-dose pilot study in healthy adults ages 18 to 45 years. Eligible subjects (N = 18) were randomized to one of six treatment sequences that contained three treatment arms: Fp MDPI 400 mu g/inhalation x two inhalations (800 mu g total dose); Fp DPI 250 mu g/inhalation x four.(1000,mu g total dose); and Fp MDI 220 mu g/inhalation x four (880 mu g total dose). Pharmacokinetics (area under concentration-versus-time curve [AUC] maximum plasma concentration [C-max], time to C-max [t(max)] and elimination half-life [t(1/2)]), safety, and tolerability were assessed for each treatment. Results: Plasma Fp concentration-versus-time curves were comparable across treatments. Geometric mean AUC(0-t) and Cmax for Fp MDPI 800 mu g were 19% and 18% higher, respectively, compared with Fp DPI 1000 mu g, and 47% and 82% higher, respectively, compared with Fp MDI 880 mu g. Median t(max) (60.0-60.6 minutes) and median t(1/2) (9.1-9.8 hours) were comparable across the three treatments. Single-dose Fp was well tolerated, with no new safety issues noted. Conclusion: Single-dose administration of Fp MDPI 800 mu g produced systemic exposure comparable with those for Fp DPI 1000 mu g and Fp MDI 880 mu g.
引用
收藏
页码:365 / 371
页数:7
相关论文
共 50 条
  • [1] Efficacy of fluticasone metered-dose inhaler and dry powder inhaler for pediatric asthma
    Miyahara, Hiroaki
    Korematsu, Seigo
    Nagakura, Tomokazu
    Izumi, Tatsuro
    PEDIATRICS INTERNATIONAL, 2008, 50 (01) : 103 - 108
  • [2] Pharmacokinetic Comparison of a Unit Dose Dry Powder Inhaler with a Multidose Dry Powder Inhaler for Delivery of Fluticasone Furoate
    Mehta, Rashmi
    Moore, Alison
    Riddell, Kylie
    Joshi, Shashidhar
    Chan, Robert
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (05) : 332 - 338
  • [3] The Genuair® inhaler: a novel, multidose dry powder inhaler
    Chrystyn, H.
    Niederlaender, C.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2012, 66 (03) : 309 - 317
  • [4] FLUTICASONE PROPIONATE AND FLUTICASONE PROPIONATE/SALMETEROL MULTIDOSE DRY POWDER INHALER PHARMACOKINETICS IN PATIENTS WITH PERSISTENT ASTHMA
    Ratner, P.
    Yiu, G.
    Nugent, C.
    Song, S.
    Caracta, C.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2016, 117 (05) : S65 - S66
  • [5] Efficacy and safety of mometasone furoate dry powder inhaler vs fluticasone propionate metered-dose inhaler in asthma subjects previously using fluticasone propionate
    Wardlaw, A
    Larivee, P
    Eller, J
    Cockcroft, DW
    Ghaly, L
    Harris, AG
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2004, 93 (01) : 49 - 55
  • [6] Pharmacokinetics of Salbutamol Delivered from the Unit Dose Dry Powder Inhaler: Comparison with the Metered Dose Inhaler and Diskus Dry Powder Inhaler
    Moore, Alison
    Riddell, Kylie
    Joshi, Shashidhar
    Chan, Robert
    Mehta, Rashmi
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (03) : 164 - +
  • [7] Efficacy and tolerability of beclomethasone dipropionate delivered by a novel multidose dry powder inhaler (Clickhaler®) versus a metered-dose inhaler in children with asthma
    Adler, LM
    Anand, C
    Wright, FGD
    Barrett, CF
    McKeith, D
    Clark, WIC
    Maksimczyk, P
    Martin, GDR
    McKinnon, C
    Raffles, AKM
    Buck, H
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 2001, 62 (11): : 758 - 769
  • [8] Handling of inhaler devices in actual pulmonary practice: Metered-dose inhaler versus dry powder inhalers
    Khassawneh, Basheer Y.
    Al-Ali, Musa K.
    Alzoubi, Karem H.
    Batarseh, Morad Z.
    Al-Safi, Saafan A.
    Sharara, Abdelmonem M.
    Alnasr, Hatem M.
    RESPIRATORY CARE, 2008, 53 (03) : 324 - 328
  • [9] A Novel Multidose Dry Powder Inhaler for the Delivery of Various Types of Inhalation Powder
    Greguletz, R.
    Arlt, M.
    Anke, S.
    Goede, J.
    de Boer, A. Haaije
    Frijlink, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [10] Easyhaler(R), a novel multidose powder inhaler - Comparison with metered dose inhaler
    Silvasti, M
    Sormunen, H
    Laurikainen, K
    Lahelma, S
    Toivanen, P
    DRUGS OF TODAY, 1996, 32 (05) : 353 - 363