COMPARISON OF SPECTRAL RESPONSE OF NEAR-INFRARED SPECTROMETERS USED FOR ROUTINE ANALYSES .2. STUDY OF THE TRANSFER OF CALIBRATION BETWEEN INSTRUMENTS

被引:0
|
作者
DESAINTDO, I [1 ]
BERTRAND, D [1 ]
机构
[1] INRA,TECHNOL APPL NUTR LAB,F-44026 NANTES 03,FRANCE
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:157 / 161
页数:5
相关论文
共 50 条
  • [31] Deployment strategy of multiple miniaturized near-infrared spectrometers based on spectral transfer for characterizing soil organic matter and nitrogen
    Shi, Zhuolin
    Ren, Zhaoxia
    Yang, Zengling
    Cai, Linwei
    Huang, Yuanping
    Ge, Chenjun
    Han, Lujia
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 320
  • [32] COMPARISON BETWEEN KJELDAHL AND NEAR-INFRARED PROTEIN ANALYSES ON VEGETATIVE AND HEAD SAMPLES OF WHEAT
    KLEPPER, L
    WILHELMI, K
    CROP SCIENCE, 1979, 19 (06) : 923 - 925
  • [33] A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometers
    Pereira, Claudete Fernandes
    Pimentel, Maria Fernanda
    Harrop Galvao, Roberto Kawakami
    Honorato, Fernanda Araujo
    Stragevitch, Luiz
    Martins, Marcelo Nascimento
    ANALYTICA CHIMICA ACTA, 2008, 611 (01) : 41 - 47
  • [34] NEAR-INFRARED REFLECTANCE SPECTROSCOPY .2. EFFECT OF CALIBRATION SET SELECTION ON ACCURACY OF METHOD
    BARTON, FE
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1991, 74 (05): : 853 - 856
  • [35] Establishment of instrument operation qualification and routine performance qualification procedures for handheld near-infrared spectrometers used at different locations within a laboratory network
    Eady, Matthew
    Payne, Michael
    Changpim, Chayanee
    Jinnah, Mohammed
    Sortijas, Steve
    Jenkins, David
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 267
  • [36] Study on Cefradine Granules Component Analysis and Calibration Transfer Method Based on Near-Infrared Spectroscopy
    Zhou Zi-kun
    Li Chen-xi
    Wang Zhe
    Liu Rong
    Chen Wen-liang
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (11) : 3562 - 3566
  • [37] Study on Spectral Calibration of Discrimination of Corn Variety Using Near-Infrared Spectra Based on DS Algorithm
    Liu Pei-zhong
    Zhang Li-ping
    Li Wei-jun
    Qin Hong
    Dong Xiao-li
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (06) : 1533 - 1537
  • [38] A spectral transfer procedure for application of a single class-model to spectra recorded by different near-infrared spectrometers for authentication of olives in brine
    Oliveri, Paolo
    Casolino, Maria Chiara
    Casale, Monica
    Medini, Luca
    Mare, Francesca
    Lanteri, Silvia
    ANALYTICA CHIMICA ACTA, 2013, 761 : 46 - 52
  • [39] Calibration transfer between miniature photodiode array-based spectrometers in the near infrared assessment of mandarin soluble solids content
    Greensill, CV
    Walsh, KB
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2002, 10 (01) : 27 - 35
  • [40] NEAR-INFRARED PHOTOMETRY .2. INTRINSIC COLORS AND THE ABSOLUTE CALIBRATION FROM ONE TO 5 MICRON
    KOORNNEEF, J
    ASTRONOMY & ASTROPHYSICS, 1983, 128 (01) : 84 - 93