COMPARISON OF SPECTRAL RESPONSE OF NEAR-INFRARED SPECTROMETERS USED FOR ROUTINE ANALYSES .2. STUDY OF THE TRANSFER OF CALIBRATION BETWEEN INSTRUMENTS

被引:0
|
作者
DESAINTDO, I [1 ]
BERTRAND, D [1 ]
机构
[1] INRA,TECHNOL APPL NUTR LAB,F-44026 NANTES 03,FRANCE
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:157 / 161
页数:5
相关论文
共 50 条
  • [21] A dual model strategy to transfer multivariate calibration models for near-infrared spectral analysis
    Wang, Jiajun
    Li, Zhengfeng
    Wang, Yi
    Liu, Yan
    Cai, Wensheng
    Shao, Xueguang
    SPECTROSCOPY LETTERS, 2016, 49 (05) : 348 - 354
  • [22] Improving calibration transfer between shortwave near infrared silicon photodiode array instruments
    Hayes, Clinton J.
    Walsh, Kerry B.
    Greensill, Colin V.
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2016, 24 (01) : 59 - 68
  • [23] THE OPTICAL AND NEAR-INFRARED COLORS OF GALAXIES .2. SPECTRAL CLASSIFICATION
    BERSHADY, MA
    ASTRONOMICAL JOURNAL, 1995, 109 (01): : 87 - 120
  • [24] Transfer of multivariate calibrations between four near-infrared spectrometers using orthogonal signal correction
    Woody, NA
    Feudale, RN
    Myles, AJ
    Brown, SD
    ANALYTICAL CHEMISTRY, 2004, 76 (09) : 2595 - 2600
  • [25] Portable near-infrared instruments: Application for quality control of polymorphs in pharmaceutical raw materials and calibration transfer
    da Silva, Vitor Hugo
    da Silva, Janson Jose
    Pereira, Claudete Fernandes
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 134 : 287 - 294
  • [26] Transfer between different instruments of a near-infrared spectroscopic method for the identification of pharmaceutical excipients
    Palmer, K. E.
    Jee, R. D.
    Kraunsoe, J. A. E.
    Moffat, A. C.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2004, 56 : S37 - S37
  • [27] Benchtop and different miniaturized near-infrared spectrometers application study: Calibration transfer and 2D-COS for in-situ analysis of moisture content in HPMC
    Yue, Jianan
    Zhang, Hui
    Gao, Lele
    Tian, Weilu
    Luo, Junsha
    Nie, Lei
    Li, Lian
    Wu, Aoli
    Zang, Hengchang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 333
  • [28] A procedure for calibration transfer between near-infrared instruments - a worked example using a transmittance single tablet assay for piroxicam in intact tablets
    Smith, MR
    Jee, RD
    Moffat, AC
    Rees, DR
    Broad, NW
    ANALYST, 2004, 129 (09) : 806 - 816
  • [29] Rapid analysis of wheat flour by different handheld near-infrared spectrometers: A discussion of calibration model maintenance and performance comparison
    Chen, Xinyu
    Siesler, H. W.
    Yan, Hui
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 252
  • [30] CALIBRATION TRANSFER ACROSS NEAR-INFRARED SPECTROMETRIC INSTRUMENTS USING SHENKS ALGORITHM - EFFECTS OF DIFFERENT STANDARDIZATION SAMPLES
    BOUVERESSE, E
    MASSART, DL
    DARDENNE, P
    ANALYTICA CHIMICA ACTA, 1994, 297 (03) : 405 - 416