5-YEAR FOLLOW-UP EVALUATION OF THE NONCEMENTED PRESS-FIT TITANIUM HIP-JOINT ENDOPROSTHESIS

被引:0
|
作者
SERAL, F
VILLAR, JM
ESTELLER, A
VIVAR, FG
ABAD, I
GRANDE, MM
JORDA, E
ESPINAR, E
机构
[1] HOSP CRUCES, VIZCAYA, SPAIN
[2] HOSP MARQUES VALDECILLA, SANTANDER, SPAIN
[3] HOSP REG CARLOS HAYA, MALAGA, SPAIN
[4] HOSP VIRGEN CAMINO, PAMPLONA, SPAIN
[5] HOSP GEN VIRGEN LLUCH, PALMA DE MALLORCA, SPAIN
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ties with a titanium alloy stem and fixation by the Zweymuller press-fit and an Endler polyethylene threaded cup was reviewed in detail. The minimum follow-up period was 48 months and the maximum 72 months, with an average of 60 months. A scale from zero to five points was applied to evaluate pain, mobility, and motion for a total possible accumulation of 15 points. The global results of the different ethiologic groups (arthrosis, femoral head necrosis, rheumatoid arthritis, and subcapital hip fractures) have been very good and good (12-15 points) in 67.5% of the cases and fairly good and bad in 32.3%. These results have been better in femoral head necrosis than in arthrosis or rheumatoid arthritis, but not as good in subcapital hip fractures. The age groups below 60 had better results than the above 60 groups. The Singh index higher than 3 was correlated with better-than-average results. The polyethylene cup migrated horizontally (more than 4 mm) in 7.6% of the cases and vertically (more than 5 mm) in 10%. The nonevolutionary cortical remodelation of the femur does not influence the results. Prosthetic stem sinking less than 4 mm has been found in 62% of the cases, from 4 to 9 mm in 21%, and greater than 9 mm in 6%. No alterations with clinical consequences attributable to stress-shielding have been detected.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [21] 5-YEAR FOLLOW-UP EVALUATION OF CLOSED MITRAL VALVULOTOMY
    SCANNELL, JG
    TURNER, JD
    BURKE, JF
    SAIDI, F
    CIRCULATION, 1960, 22 (04) : 805 - 805
  • [22] THE CAD HIP-ARTHROPLASTY - 5-YEAR TO 10-YEAR FOLLOW-UP
    THOMAS, BJ
    SALVATI, EA
    SMALL, RD
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05): : 640 - 646
  • [23] Outcomes of press-fit radial head arthroplasty in unconstructable radial head fractures with associated elbow injuries: An average 5-year follow up
    Eyre-Brook, A., I
    Kankanalu, P.
    Majkowski, L.
    Zreik, N.
    Jones, V
    Thyagarajan, D. S.
    Ali, A. A.
    Booker, S. J.
    SHOULDER & ELBOW, 2024,
  • [24] 5-Year Follow-Up of Surgical Dislocation of the Hip for the Treatment of Femoroacetabular Impingement
    Steppacher, S. D.
    Huemmer, C.
    Kakaty, D.
    Tannest, M.
    Siebenrock, K. A.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 3S - 3S
  • [25] A 5-year follow-up of 87 immediately loaded titanium implants.
    Degidi, M
    Patianna, D
    Orsini, G
    Piattelli, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A436 - A436
  • [26] NEW ROTATORY HIP-JOINT ENDOPROSTHESIS ACCORDING TO UNIT CONSTRUCTION SYSTEM AFTER WEBER - EXPERIENCE AND RESULTS OF FOLLOW-UP CHECKS AFTER 5 YEARS
    STUHMER, G
    WEBER, BG
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1978, 116 (03): : 285 - 293
  • [27] 14-Year Median Follow-Up Using the Press-Fit Condylar Sigma Design for Total Knee Arthroplasty
    Patil, Shantanu S.
    Branovacki, George
    Martin, Mersadies R.
    Pulido, Pamela A.
    Levy, Yadin D.
    Colwell, Clifford W., Jr.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 1286 - 1290
  • [28] Laparoscopic fundoplication: 5-year follow-up
    Dassinger, MS
    Torquati, A
    Houston, HL
    Holzman, MD
    Richards, WO
    AMERICAN SURGEON, 2004, 70 (08) : 691 - 694
  • [29] 5-YEAR FOLLOW-UP OF GERIATRIC EEGS
    MULLER, HF
    GRAD, B
    ENGELSMANN, F
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 38 (01): : 108 - 108
  • [30] DOGMATISM AND LEARNING - A 5-YEAR FOLLOW-UP
    EHRLICH, HJ
    PSYCHOLOGICAL REPORTS, 1961, 9 (02) : 283 - 286