APPLICATION OF A HIGH-RESOLUTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES

被引:81
|
作者
KIM, CK
SEKI, R
MORITA, S
YAMASAKI, S
TSUMURA, A
TAKAKU, Y
IGARASHI, Y
YAMAMOTO, M
机构
[1] NATL INST RADIOL SCI,DIV RADIOECOL,3609 ISOZAKI,IBARAKI 31112,JAPAN
[2] UNIV TSUKUBA,DEPT CHEM,SAKURA,IBARAKI 305,JAPAN
[3] NATL INST AGROENVIRONM SCI,DIV WATER QUAL SCI,IBARAKI 305,JAPAN
[4] MARUBUN,CHUO KU,TOKYO 170,JAPAN
[5] KANAZAWA UNIV,LOW LEVEL RADIOACT LAB,TATSUNOKUCHI,ISHIKAWA 92312,JAPAN
关键词
HIGH RESOLUTION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; LONG-LIVED RADIONUCLIDE; DETECTION LIMIT;
D O I
10.1039/ja9910600205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Some long-lived radionuclides, such as Tc-99, Ra-226, Th-232, Np-237, U-238, Pu-239 and Pu-240 were measured using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). By using HR-ICP-MS with an ultrasonic nebulizer, the detection limits of these nuclides were 0.002-0.02 pg ml-1 and the sensitivities were 10 times better than those obtained using HR-ICP-MS without the ultrasonic nebulizer. More accurate isotopic data were also obtained using HR-ICP-MS than with quadrupole ICP-MS at lower concentrations of the analyte because of the improvement in counting statistics that can be obtained with HR-ICP-MS due to the greater efficiency of ion transmission. A comparison of the measurement of the Pu-240 to Pu-239 ratio is shown.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 50 条
  • [41] MACHINATIONS - THE LASER-ABLATION MICROPROBE INDUCTIVELY-COUPLED PLASMA - MASS-SPECTROMETER
    LONGERICH, HP
    JACKSON, SE
    FRYER, BJ
    STRONG, DF
    GEOSCIENCE CANADA, 1993, 20 (01) : 21 - 27
  • [42] ION TRAJECTORIES THROUGH THE INPUT ION OPTICS OF AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER
    VAUGHAN, MA
    HORLICK, G
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (12) : 1301 - 1311
  • [43] PRELIMINARY-RESULTS WITH A HIGH-RESOLUTION INDUCTIVELY COUPLED PLASMA FOURIER-TRANSFORM SPECTROMETER
    SPILLANE, DEM
    SNOOK, RD
    THORNE, AP
    WHEATON, JEG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (06) : 591 - 594
  • [44] High-resolution laser spectroscopy of long-lived plutonium isotopes
    Voss, A.
    Sonnenschein, V.
    Campbell, P.
    Cheal, B.
    Kron, T.
    Moore, I. D.
    Pohjalainen, I.
    Raeder, S.
    Trautmann, N.
    Wendt, K.
    PHYSICAL REVIEW A, 2017, 95 (03)
  • [45] Application of an Orthogonal Method for Optimizing an Inductively Coupled Plasma Mass Spectrometer
    Honglin Yuan
    Shenghong Hu
    Soulin Lin
    Shan Gao
    Analytical Sciences, 2002, 18 : 701 - 704
  • [46] Application of an orthogonal method for optimizing an inductively coupled plasma mass spectrometer
    Yuan, HL
    Hu, SH
    Lin, SL
    Gao, S
    ANALYTICAL SCIENCES, 2002, 18 (06) : 701 - 704
  • [47] PLASMA SOURCE-MASS SPECTROMETRY USING AN INDUCTIVELY COUPLED PLASMA AND A HIGH-RESOLUTION QUADRUPOLE MASS FILTER
    DATE, AR
    GRAY, AL
    ANALYST, 1981, 106 (1269) : 1255 - 1267
  • [48] ANALYSES OF SILICON WAFERS BY A HIGH-RESOLUTION SECONDARY ION MASS-SPECTROMETER
    TAYA, S
    SUZUKI, M
    TSUYAMA, H
    KANOMATA, I
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1978, 27 (01): : 63 - 76
  • [49] HIGH-RESOLUTION SIMS WITH ION-CYCLOTRON RESONANCE MASS-SPECTROMETER
    PLESKO, S
    ZWINSELMAN, JJ
    ALLEMANN, M
    KELLERHALS, HP
    HELVETICA PHYSICA ACTA, 1984, 57 (06): : 765 - 765