APPLICATION OF A HIGH-RESOLUTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES

被引:81
|
作者
KIM, CK
SEKI, R
MORITA, S
YAMASAKI, S
TSUMURA, A
TAKAKU, Y
IGARASHI, Y
YAMAMOTO, M
机构
[1] NATL INST RADIOL SCI,DIV RADIOECOL,3609 ISOZAKI,IBARAKI 31112,JAPAN
[2] UNIV TSUKUBA,DEPT CHEM,SAKURA,IBARAKI 305,JAPAN
[3] NATL INST AGROENVIRONM SCI,DIV WATER QUAL SCI,IBARAKI 305,JAPAN
[4] MARUBUN,CHUO KU,TOKYO 170,JAPAN
[5] KANAZAWA UNIV,LOW LEVEL RADIOACT LAB,TATSUNOKUCHI,ISHIKAWA 92312,JAPAN
关键词
HIGH RESOLUTION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; LONG-LIVED RADIONUCLIDE; DETECTION LIMIT;
D O I
10.1039/ja9910600205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Some long-lived radionuclides, such as Tc-99, Ra-226, Th-232, Np-237, U-238, Pu-239 and Pu-240 were measured using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). By using HR-ICP-MS with an ultrasonic nebulizer, the detection limits of these nuclides were 0.002-0.02 pg ml-1 and the sensitivities were 10 times better than those obtained using HR-ICP-MS without the ultrasonic nebulizer. More accurate isotopic data were also obtained using HR-ICP-MS than with quadrupole ICP-MS at lower concentrations of the analyte because of the improvement in counting statistics that can be obtained with HR-ICP-MS due to the greater efficiency of ion transmission. A comparison of the measurement of the Pu-240 to Pu-239 ratio is shown.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 50 条
  • [1] APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES IN ENVIRONMENTAL-SAMPLES - A REVIEW
    IGARASHI, Y
    KIM, CK
    TAKAKU, Y
    SHIRAISHI, K
    YAMAMOTO, M
    IKEDA, N
    ANALYTICAL SCIENCES, 1990, 6 (02) : 157 - 164
  • [2] Determination of long-lived radionuclides in concrete matrix by laser ablation inductively coupled plasma mass spectrometry
    Gastel, M
    Becker, JS
    Kuppers, G
    Dietze, HJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (14) : 2051 - 2059
  • [3] Determination of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using different nebulizers
    Becker, JS
    Soman, RS
    Sutton, KL
    Caruso, JA
    Dietze, HJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (06) : 933 - 937
  • [4] HIGH-RESOLUTION MASS-SPECTROMETER
    ALEXANDRU, G
    DUTESCU, N
    MOLNAR, S
    STUDII SI CERCETARI DE FIZICA, 1972, 24 (06): : 765 - +
  • [5] PROGRESS IN ANALYTICAL APPLICATION OF AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER SYSTEM
    LUCK, J
    SIEWERS, U
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (02): : 129 - 132
  • [6] CHARACTERIZATION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING A HIGH-RESOLUTION MASS-SPECTROMETER
    REED, NM
    CAIRNS, RO
    HUTTON, RC
    TAKAKU, Y
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) : 881 - 896
  • [7] Application of plasma mass spectrometry for half-life measurement of medium and long-lived radionuclides
    Braysher, Emma
    Russell, Ben
    Read, David
    27TH INTERNATIONAL NUCLEAR PHYSICS CONFERENCE (INPC2019), 2020, 1643
  • [8] HIGH-RESOLUTION QUADRUPOLE MASS-SPECTROMETER
    KONENKOV, NV
    MOGILCHENKO, GA
    SILAKOV, SS
    SHAGIMURATOV, GI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (02) : 433 - 435
  • [9] HIGH-RESOLUTION ISOCHRONOUS MASS-SPECTROMETER FOR SPACE PLASMA APPLICATIONS
    GUBLER, L
    WURZ, P
    BOCHSLER, P
    MOBIUS, E
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 148 (1-2): : 77 - 96
  • [10] MOLECULAR IONIZATION IN THE INTERFACE OF AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER
    TOGASHI, H
    HASHIZUME, A
    NIWA, Y
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (04) : 561 - 568