PULSED AMPEROMETRIC DETECTION OF GLUCOSE USING A MEDIATED ENZYME ELECTRODE

被引:18
|
作者
GUNASINGHAM, H
TAN, CH
NG, HM
机构
[1] Department of Chemistry, National University of Singapore, Kent RidgeSingapore
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1990年 / 287卷 / 02期
关键词
D O I
10.1016/0022-0728(90)80010-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pulsed amperometric detection (PAD) was employed for the detection of glucose using a tetrathiafulvalene mediated enzyme electrode in flow analysis. The effect of various parameters is described and comparisons are made with the dc amperometric (dc) mode. The results show that the PAD mode gives a higher precision in long term flow injection analysis and is less susceptible to the flow rate. The linear range is the same although the current in the PAD mode is generally lower. The detection limits for the PAD and dc modes are 2.5 μM and 1.25 μM, respectively. © 1990.
引用
收藏
页码:349 / 362
页数:14
相关论文
共 50 条
  • [31] AN AMPEROMETRIC ENZYME ELECTRODE FOR MONITORING BRAIN GLUCOSE IN THE FREELY MOVING RAT
    BOUTELLE, MG
    STANFORD, C
    FILLENZ, M
    ALBERY, WJ
    BARTLETT, PN
    [J]. NEUROSCIENCE LETTERS, 1986, 72 (03) : 283 - 288
  • [32] ENZYME ELECTRODE FOR AMPLIFICATION OF NAD(+)/NADH USING GLYCEROL DEHYDROGENASE AND DIAPHORASE WITH AMPEROMETRIC DETECTION
    TANG, XJ
    JOHANSSON, G
    [J]. ANALYTICAL LETTERS, 1995, 28 (15) : 2595 - 2606
  • [33] MEASUREMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION IN SHEEP WITH AN AMPEROMETRIC ENZYME ELECTRODE
    KERNER, W
    ZIER, H
    STEINBACH, G
    HAAS, J
    WARHADPANDE, R
    BRUCKEL, J
    PFEIFFER, EF
    [J]. DIABETOLOGIA, 1987, 30 (07) : A539 - A539
  • [34] Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection
    García, CD
    Henry, CS
    [J]. ANALYTICA CHIMICA ACTA, 2004, 508 (01) : 1 - 9
  • [35] ELECTROPOLYMERIZED COBALT TETRAKIS(ORTHO-AMINOPHENYL)PORPHYRIN FILM MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    OYAMA, N
    OHSAKA, T
    MIZUNUMA, M
    KOBAYASHI, M
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (22) : 2536 - 2537
  • [36] Amperometric Detection of Glucose Using a Modified Nitrogen-Doped Nanocrystalline Diamond Electrode
    Xu, Zhenqing
    Kumar, Ashok
    Kumar, Arun
    [J]. JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2005, 1 (04) : 416 - 420
  • [37] Development of an amperometric enzyme electrode biosensor for fish freshness detection
    Ghosh, S
    Sarker, D
    Misra, TN
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) : 58 - 62
  • [38] Development of an amperometric enzyme electrode biosensor for fish freshness detection
    Ghosh, S.
    Sarker, D.
    Misra, T.N.
    [J]. Sensors and Actuators, B: Chemical, 1998, B53 (1-2): : 58 - 62
  • [39] DETERMINATION OF GLUTAMINE IN SERUM USING AN AMPEROMETRIC ENZYME ELECTRODE
    VILLARTA, RL
    PALLESCHI, G
    SULEIMAN, A
    GUILBAULT, GG
    [J]. ELECTROANALYSIS, 1992, 4 (01) : 27 - 31
  • [40] Nafion coating the ferrocenylalkanethiol and encapsulated glucose oxidase electrode for amperometric glucose detection
    Peng, Yong
    Wei, Chuan-Wan
    Liu, You-Nian
    Li, Juan
    [J]. ANALYST, 2011, 136 (19) : 4003 - 4007