Continuous non-invasive blood pressure during continuous repositioning by pulse transit time

被引:1
|
作者
Jeong, Hieyong [1 ]
Yoshimoto, Kayo [2 ]
Wang, Tianyi [3 ]
Ohno, Takafumi [1 ]
Yamada, Kenji [1 ]
Kido, Michiko [3 ]
Ohno, Yuko [3 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept R&D Innovat Healthcare, 1-7 Yamada Oka, Suita, Osaka 5650871, Japan
[2] Osaka City Univ, Grad Sch Engn, Dept Elect & Informat Engn, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Div Hlth Sci, Suita, Osaka, Japan
来源
COGENT ENGINEERING | 2016年 / 3卷 / 01期
关键词
continuous non-invasive blood pressure; pulse transit time; pulse wave velocity; severely handicapped children; side effects;
D O I
10.1080/23311916.2016.1221202
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of the present study was to propose a method to measure continuous non-invasive arterial pressure (CNAP) of severely handicapped patient during continuous repositioning. We have been interested in healthcare for severely handicapped children. Although their long stay in hospital could be led to a circulatory disorder or a serious secondary disease, there was little way to give an adequate healthcare service for them due to several kinds of side effects. Thus, we developed the non-invasive sensor system to measure pulse transit time (PTT) through the different output signal between the two different measuring points. The proposed extended model of algorithm enabled us to measure continuous blood pressure (BP) with the measured PTT. The algorithm considered the influence of gravity on BP; there was no need to re-tune the system even if the posture of patient was changed. We performed the continuous repositioning experiment from the supine posture to 45 or 75 degrees postures after the effectiveness of the proposed algorithm was confirmed. Through experimental results, it was found that the proposed method has the strongest correlation with commercial BP device. The experimental results showed that it was possible for the proposed algorithm to measure CNAP during continuous repositioning without the re-tune of system. It was recommended that some points of developed prototype hardware were necessary to be improved and the integration of other bio signals was more helpful for providing important insight into the overall physical condition.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Adaptive Algorithm for Continuous Monitoring of Blood Pressure Using a Pulse Transit Time
    Jadooei, Ali
    Zaderykhin, O.
    Shulgin, V. I.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 297 - 301
  • [32] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178
  • [33] Continuous Cuffless Blood Pressure Estimation Based on Pulse Transit Time: A New Evaluation with Invasive BP Reference
    Tang, Zunyi
    Chen, Ying
    Liu, Shing-Hong
    Kobayashi, Toshio
    Chen, Wenxi
    2019 IEEE 10TH INTERNATIONAL CONFERENCE ON AWARENESS SCIENCE AND TECHNOLOGY (ICAST 2019), 2019, : 516 - 520
  • [34] CONTINUOUS NON-INVASIVE ARTERIAL PRESSURE (CNAP) MEASUREMENT: COMPARING THE CNAP DEVICE TO THE NON-INVASIVE BLOOD PRESSURE ARM CUFF DURING SURGERY
    Khera, J. K.
    Solangasenathirajan, S.
    Jones, M.
    Jonas, M.
    INTENSIVE CARE MEDICINE, 2013, 39 : S295 - S295
  • [35] Non-invasive continuous blood pressure monitoring: a review of current applications
    Elena Chung
    Guo Chen
    Brenton Alexander
    Maxime Cannesson
    Frontiers of Medicine, 2013, 7 : 91 - 101
  • [36] CNAP - EVOLUTION OF CONTINUOUS NON-INVASIVE ARTERIAL BLOOD PRESSURE MONITORING
    Fortin, J.
    Wellisch, A.
    Maier, K.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [37] The applications of continuous non-invasive blood pressure monitoring in behavioural research
    Steptoe, A
    HOMEOSTASIS IN HEALTH AND DISEASE, 1995, 36 (5-6): : 325 - 334
  • [38] Review of Photoplethysmography Based Non-invasive Continuous Blood Pressure Methods
    Tjahjadi, Hendrana
    Ramli, Kalamullah
    2017 15TH INTERNATIONAL CONFERENCE ON QUALITY IN RESEARCH (QIR) - INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND COMPUTER ENGINEERING, 2017, : 173 - 178
  • [39] Clinical Study of Continuous Non-Invasive Blood Pressure Monitoring in Neonates
    Rao, Anoop
    Eskandar-Afshari, Fatima
    Weiner, Ya'el
    Billman, Elle
    McMillin, Alexandra
    Sella, Noa
    Roxlo, Thomas
    Liu, Junjun
    Leong, Weyland
    Helfenbein, Eric
    Walendowski, Alan
    Muir, Arthur
    Joseph, Alexandria
    Verma, Archana
    Ramamoorthy, Chandra
    Honkanen, Anita
    Green, Gabrielle
    Drake, Keith
    Govindan, Rathinaswamy B.
    Rhine, William
    Quan, Xina
    SENSORS, 2023, 23 (07)
  • [40] Continuous Non-invasive Blood Pressure Monitoring Based on Applanation Tonometry
    Ariyadamrogkwan, Chollitha
    Chitsakul, Kitiphol
    Treetriluxana, Suradaj
    2014 FOURTH JOINT INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONIC AND ELECTRICAL ENGINEERING (JICTEE 2014), 2014,