Continuous non-invasive blood pressure during continuous repositioning by pulse transit time

被引:1
|
作者
Jeong, Hieyong [1 ]
Yoshimoto, Kayo [2 ]
Wang, Tianyi [3 ]
Ohno, Takafumi [1 ]
Yamada, Kenji [1 ]
Kido, Michiko [3 ]
Ohno, Yuko [3 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept R&D Innovat Healthcare, 1-7 Yamada Oka, Suita, Osaka 5650871, Japan
[2] Osaka City Univ, Grad Sch Engn, Dept Elect & Informat Engn, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Div Hlth Sci, Suita, Osaka, Japan
来源
COGENT ENGINEERING | 2016年 / 3卷 / 01期
关键词
continuous non-invasive blood pressure; pulse transit time; pulse wave velocity; severely handicapped children; side effects;
D O I
10.1080/23311916.2016.1221202
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of the present study was to propose a method to measure continuous non-invasive arterial pressure (CNAP) of severely handicapped patient during continuous repositioning. We have been interested in healthcare for severely handicapped children. Although their long stay in hospital could be led to a circulatory disorder or a serious secondary disease, there was little way to give an adequate healthcare service for them due to several kinds of side effects. Thus, we developed the non-invasive sensor system to measure pulse transit time (PTT) through the different output signal between the two different measuring points. The proposed extended model of algorithm enabled us to measure continuous blood pressure (BP) with the measured PTT. The algorithm considered the influence of gravity on BP; there was no need to re-tune the system even if the posture of patient was changed. We performed the continuous repositioning experiment from the supine posture to 45 or 75 degrees postures after the effectiveness of the proposed algorithm was confirmed. Through experimental results, it was found that the proposed method has the strongest correlation with commercial BP device. The experimental results showed that it was possible for the proposed algorithm to measure CNAP during continuous repositioning without the re-tune of system. It was recommended that some points of developed prototype hardware were necessary to be improved and the integration of other bio signals was more helpful for providing important insight into the overall physical condition.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Feasibility of continuous non-invasive blood pressure measurement in infants
    Schraa, O
    Andriessen, P
    Smit, B
    van den Bosch-Ruis, W
    van Koppen, M
    Settels, JJ
    JOURNAL OF HYPERTENSION, 2004, 22 : S280 - S280
  • [22] NON-INVASIVE CONTINUOUS MONITORING OF SYSTEMIC BLOOD-PRESSURE
    SPORTICHE, M
    JARDIN, F
    BOUROKBA, A
    MARGAIRAZ, A
    NOUVELLE PRESSE MEDICALE, 1980, 9 (18): : 1306 - &
  • [23] The System of Indicators of the Continuous Non-Invasive Blood Pressure Measurement
    Timokhov, Gennady, V
    Semenova, Evgeniia A.
    Pivovarov, Vladimir V.
    PROCEEDINGS OF THE 2021 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (ELCONRUS), 2021, : 1860 - 1864
  • [24] Continuous Non-Invasive Blood Pressure Monitoring Using Photoplethysmography
    Nye, Ross
    Zhang, Zhe
    Fang, Qiang
    2015 INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2015, : 176 - 179
  • [25] Research on the non-invasive continuous blood pressure monitoring models cluster based on pulse wave
    Wu H.
    Ji Z.
    Li M.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (07): : 224 - 234
  • [26] Continuous blood pressure monitoring during exercise using pulse wave transit time measurement
    Lass, J
    Meigas, K
    Karai, D
    Kattai, R
    Kaik, J
    Rossmann, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2239 - 2242
  • [27] CONTINUOUS NON-INVASIVE BLOOD-PRESSURE - RELIABILITY OF FINAPRES DURING THE VALSALVA MANEUVER
    IMHOLZ, BPM
    VANMONTFRANS, GA
    SETTELS, JJ
    VANDERHOEVEN, GMA
    KAREMAKER, JM
    WIELING, W
    JOURNAL OF HYPERTENSION, 1988, 6 (02) : 176 - 176
  • [28] Impact of continuous, non-invasive blood pressure measurement on sleep quality during polysomnography
    Thomas Wibmer
    Benedikt Schildge
    Christoph Fischer
    Stefanie Brunner
    Cornelia Kropf-Sanchen
    Stefan Rüdiger
    Ioanna Blanta
    Kathrin M. Stoiber
    Wolfgang Rottbauer
    Christian Schumann
    Sleep and Biological Rhythms, 2013, 11 : 254 - 260
  • [29] Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology
    Maggi, Roberto
    Viscardi, Valentina
    Furukawa, Toshiyuki
    Brignole, Michele
    EUROPACE, 2010, 12 (11): : 1616 - 1622
  • [30] Impact of continuous, non-invasive blood pressure measurement on sleep quality during polysomnography
    Wibmer, Thomas
    Schildge, Benedikt
    Fischer, Christoph
    Brunner, Stefanie
    Kropf-Sanchen, Cornelia
    Ruediger, Stefan
    Blanta, Ioanna
    Stoiber, Kathrin M.
    Rottbauer, Wolfgang
    Schumann, Christian
    SLEEP AND BIOLOGICAL RHYTHMS, 2013, 11 (04) : 254 - 260