DIGITAL RADIOGRAPHY CAN REDUCE SCOLIOSIS X-RAY-EXPOSURE

被引:12
|
作者
KLING, TF
COHEN, MJ
LINDSETH, RE
DEROSA, G
机构
[1] Indiana University School of Medicine, Indianapolis, IN
关键词
D O I
10.1097/00007632-199009000-00008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Digital radiology is a new computerized system of acquir-ing x-rays in a digital (electronic) format. It possesses a greatly expanded dose response curve that allows a very broad range of x-ray dose to produce a diagnostic image. Potential advantages include significantly reduced radia-tion exposure without loss of image quality, acquisition of images of constant density irrespective of under or over exposure, and reduced repeat rates for unsatisfactory films. The authors prospectively studied 30 adolescents with scoliosis who had both conventional (full dose) and digital (full, one-half, or one-third dose) x-rays. They found digital made AP and lateral image with all anatomic areas clearly depicted at full and one-half dose. Digital laterals were better at full dose and equal to conventional at one-half dose. Cobb angles were easily measured on all one-third dose AP and on 8 of 10 one- third dose digital laterals. Digital clearly depicted the Risser sign at one-half and one-third dose and the repeat rate was nil in this study, indicating digital compensates well for exposure errors. The study indicates that digital does allow radiation dose to be reduced by at least one-half in scoliosis patients and that it does have improved image quality with good contrast over a wide range of x-ray exposure. © Lippincott-Raven Publishers.
引用
收藏
页码:880 / 885
页数:6
相关论文
共 50 条
  • [21] MEDICAL X-RAY-EXPOSURE OF THE HUMAN-EMBRYO AND FETUS
    METTLER, FA
    [J]. HEALTH PHYSICS, 1983, 44 (01): : 84 - 85
  • [22] INVESTIGATIONS OF X-RAY-EXPOSURE USING PLANE SCANNING MIRRORS
    BIEBER, M
    SCHEUNEMANN, HU
    BETZ, H
    HEUBERGER, A
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1983, 1 (04): : 1271 - 1275
  • [23] PRENATAL X-RAY-EXPOSURE AND CHILDHOOD-CANCER IN TWINS
    HARVEY, EB
    BOICE, JD
    HONEYMAN, M
    FLANNERY, JT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1985, 312 (09): : 541 - 545
  • [24] VAPOR DEVELOPMENT OF PMMA RESISTS UNDER X-RAY-EXPOSURE
    LEHOCKEY, EM
    REID, I
    [J]. SURFACE AND INTERFACE ANALYSIS, 1988, 11 (6-7) : 302 - 306
  • [25] EXOEMISSION MECHANISMS AS DISCERNED VIA X-RAY-EXPOSURE VARIATIONS
    SORKIN, B
    KAAMBRE, H
    [J]. PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1990, 117 (01): : K33 - K36
  • [26] MEDICAL X-RAY-EXPOSURE OF THE HUMAN-EMBRYO AND FETUS
    SYED, IB
    SAMOLS, E
    [J]. HEALTH PHYSICS, 1982, 42 (01): : 61 - 64
  • [27] Flexible X-ray Detector for Automatic Exposure Control in Digital Radiography
    Oh, Kyungmin
    Han, Moojae
    Kim, Jinseon
    Heo, Yeji
    Kim, Kyotae
    Cho, Gyuseok
    Song, Yongkeun
    Cho, Sungho
    Heo, Seunguk
    Kim, Jinyoung
    Park, Sungkwang
    Nam, Sanghee
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (11) : 11473 - 11476
  • [28] INVESTIGATION OF X-RAY-EXPOSURE USING PLANE SCANNING MIRRORS
    BIEBER, M
    BETZ, H
    HEUBERGER, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 208 (1-3): : 281 - 286
  • [29] APPLICATION OF EFFECTIVE DOSE EQUIVALENT TO MEDICAL X-RAY-EXPOSURE
    KIKUCHI, T
    ISE, T
    [J]. HEALTH PHYSICS, 1984, 46 (06): : 1325 - 1325
  • [30] X-RAY-EXPOSURE FROM A SIMULATOR FLUOROSCOPE WITHOUT THE EXPOSURE SWITCH DEPRESSED
    LARSEN, R
    MICHAEL, B
    BLOCH, P
    [J]. MEDICAL PHYSICS, 1982, 9 (04) : 619 - 619