REPAIR OF OPEN, COMMINUTED FRACTURES OF THE RADIUS AND ULNA IN A CALF WITH A TRANSARTICULAR TYPE-II EXTERNAL SKELETAL FIXATOR

被引:0
|
作者
ANDERSON, DE
STJEAN, G
DESROCHERS, A
机构
来源
AGRI-PRACTICE | 1994年 / 15卷 / 09期
关键词
D O I
暂无
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
A 4-day-old Holstein heifer presented with a right distal radius and ulna fracture. Repair of the open, comminuted, short oblique, distal diaphyseal fracture was made using a trans-articular Type If external skeletal fixator. The fixator was applied using centrally threaded, positive profile pins. The fractures healed 8 weeks after fixation.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [31] SURGICAL REPAIR OF 2 SALTER TYPE-II TIBIAL FRACTURES
    MARKS, DL
    VETERINARY MEDICINE & SMALL ANIMAL CLINICIAN, 1984, 79 (05): : 649 - 652
  • [32] Treatment of comminuted tibial shaft fractures in four dogs with the use of interlocking nail connected with type I external fixator
    Piorek, A.
    Adamiak, Z.
    Jaskolska, M.
    Zhalniarovich, Y.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2012, 15 (04): : 661 - 666
  • [33] Circular External Fixator Assisted Open Reduction Combined With Locking Plate Fixation for Intra-articular Comminuted Fractures of the Calcaneus
    Hou, Jiguang
    Zhang, Nan
    Chen, Guodong
    Wang, Qi
    Zhang, Shenghua
    Yang, Kun
    Zang, Hongwei
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (03): : 437 - 443
  • [34] Evaluation of Ligamentotaxis in Management of Comminuted Intra-articular Fractures of Distal Radius Using Spanning Naseer-Awais (NA) External Fixator
    Iqbal, Mohammed
    Sami, Abdul Latif
    Akram, M.
    Masood, Faisal
    Awais, S. M.
    Hanif, Asif
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2011, 17 (03): : 286 - 291
  • [35] UNREAMED INTERLOCKING NAIL VERSUS EXTERNAL FIXATOR FOR OPEN TYPE-III TIBIA FRACTURES
    TU, YK
    LIN, CH
    SU, JI
    HSU, DT
    CHEN, RJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 39 (02): : 361 - 367
  • [36] Use of a type-III trilateral external skeletal fixation device in three deer with comminuted fractures
    Mills, ML
    Holland, M
    Cooper, R
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1996, 208 (04) : 559 - &
  • [37] USE OF AN AIMING DEVICE FOR APPLICATION OF A TYPE-II (BILATERAL) EXTERNAL FIXATOR TO A FRACTURED TIBIA OF A DOG
    JOHNSON, KA
    ROE, SC
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1988, 192 (11) : 1573 - 1576
  • [38] Stiffness of a type II external skeletal fixator and locking compression plate in a fracture gap model
    Muro, Noelle M.
    Gilley, Robert S.
    Kemper, Andrew R.
    Benitez, Marian E.
    Barry, Sabrina L.
    McNally, Craig
    VETERINARY SURGERY, 2021, 50 (03) : 622 - 632
  • [39] Treatment of severely comminuted intra-articular fractures of the distal end of the radius by open reduction and combined internal and external fixation
    Rogachefsky, RA
    Lipson, SR
    Applegate, B
    Ouellette, EA
    Savenor, AM
    McAuliffe, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04): : 509 - 519
  • [40] Type-II external fixation, using new clamps and positive-profile threaded pins, for treatment of fractures of the radius and tibia in dogs
    Kraus, KH
    Wotton, HM
    Boudrieau, RJ
    Schwarz, L
    Diamond, D
    Minihan, A
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1998, 212 (08) : 1267 - +