BASIC TECHNICAL PROPERTIES OF A SYSTEM FOR DIRECT ACQUISITION OF DIGITAL INTRAORAL RADIOGRAPHS

被引:51
|
作者
WELANDER, U
NELVIG, P
TRONJE, G
MCDAVID, WD
DOVE, SB
MORNER, AC
CEDERLUND, T
机构
[1] REGAM MED SYST AB, SUNDSVALL, SWEDEN
[2] UNIV TEXAS, HLTH SCI CTR, DEPT DENT DIAGNOST SCI, SAN ANTONIO, TX 78284 USA
[3] HUDDINGE UNIV HOSP, DEPT HOSP PHYS, S-14186 HUDDINGE, SWEDEN
关键词
D O I
10.1016/0030-4220(93)90180-C
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The Sens-A-Ray system for direct digital intraoral radiography may be used with any computer compatible with an IBM PC/AT. The system relies on a charge-coupled device designed for direct conversion of x-ray energy to an electronic signal. It is the first such device for direct acquisition of radiographs. Technical properties of charge-coupled device detectors when exposed to radiation energies in the range of x-rays used in dental radiography have been studied. Even in the absence of light or x-radiation there is a spontaneous generation of charge within a charge-coupled device detector that gives rise to a background signal, a dark current. It was found that the dark current is a linear function of exposure time. The dose response of the charge-coupled device detector was determined at nominal kilovoltages that range from 50 to 90 kVp. The dose response was shown to be a linear function of exposure. The functions for all kVp settings were practically identical. The charge-coupled device detector is more sensitive to x-radiation than conventional dental films and, consequently, its exposure range is more narrow. The signal-to-noise ratio was calculated from the digital radiographs used for the dose response test. The ratio is above 1 0 for exposures higher than about 2 muC/kg. The line spread function was determined from test radiographs of a 10 mum wide slit in a test object of 1.5 mm thick tantalum. After curve fitting, the line spread function could be expressed as the sum of a Gaussian and an exponential function. Presampling modulation transfer functions valid at the detector plane and at an object plane were calculated from fitted data on the line spread function. It is concluded that the Sens-A-Ray system has such technical properties that it may replace conventional film-based systems.
引用
收藏
页码:506 / 516
页数:11
相关论文
共 50 条
  • [41] SINGLE EXPOSURE SIMULTANEOUS ACQUISITION OF DIGITAL AND CONVENTIONAL RADIOGRAPHS UTILIZING UNALTERED DOSE
    OESTMANN, JW
    GREENE, R
    EUROPEAN JOURNAL OF RADIOLOGY, 1988, 8 (04) : 258 - 260
  • [42] System analysis of X-ray-sensitive CCDs and adaptive restoration of intraoral radiographs
    Peters, B
    MeyerEbrecht, D
    Lehmann, T
    Schmitt, W
    MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 450 - 461
  • [43] A basic concept of direct converting digital microphone
    Yasuno, Y
    Riko, Y
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 106 (06): : 3335 - 3339
  • [44] DEVELOPMENT OF A DIGITAL DUPLICATION SYSTEM FOR PORTABLE CHEST RADIOGRAPHS
    HOFFMANN, KR
    DOI, K
    MACMAHON, H
    CARLIN, M
    XU, XW
    GIGER, ML
    RADIOLOGY, 1992, 185 : 149 - 149
  • [45] ANALYSIS OF THE ACQUISITION OF DIGITAL COMPETENCE IN TECHNICAL DRAWING IN HIGHER EDUCATION
    Lopez-Pena, Vicente
    Lopez-Chao, Vicente
    Ramiro Aparicio, Dario
    9TH INTERNATIONAL CONFERENCE ON EDUCATION AND NEW LEARNING TECHNOLOGIES (EDULEARN17), 2017, : 5742 - 5748
  • [46] Acquisition of knowledge in the control of a simulated technical system
    Kluwe, RH
    TRAVAIL HUMAIN, 1997, 60 (01): : 61 - 85
  • [47] Assessments of the physical performance of 2 generations of 2 direct digital intraoral sensors
    Attaelmanan, AG
    Borg, E
    Gröndahl, HG
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1999, 88 (04): : 517 - 523
  • [48] Comparative investigation of subjective image quality of digital intraoral radiographs processed with 3 image-processing algorithms
    Li, G
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2004, 97 (06): : 762 - 767
  • [49] Use of Texture Feature Maps for the Refinement of Information Derived from Digital Intraoral Radiographs of Lytic and Sclerotic Lesions
    Obuchowicz, Rafal
    Nurzynska, Karolina
    Obuchowicz, Barbara
    Urbanik, Andrzej
    Piorkowski, Adam
    APPLIED SCIENCES-BASEL, 2019, 9 (15):
  • [50] FLASH DENT - AN ALTERNATIVE CHARGE-COUPLED-DEVICE SCINTILLATOR-BASED DIRECT DIGITAL INTRAORAL RADIOGRAPHIC SYSTEM
    SCARFE, WC
    FARMAN, AG
    KELLY, MS
    DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (01) : 11 - 17