BASIC TECHNICAL PROPERTIES OF A SYSTEM FOR DIRECT ACQUISITION OF DIGITAL INTRAORAL RADIOGRAPHS

被引:51
|
作者
WELANDER, U
NELVIG, P
TRONJE, G
MCDAVID, WD
DOVE, SB
MORNER, AC
CEDERLUND, T
机构
[1] REGAM MED SYST AB, SUNDSVALL, SWEDEN
[2] UNIV TEXAS, HLTH SCI CTR, DEPT DENT DIAGNOST SCI, SAN ANTONIO, TX 78284 USA
[3] HUDDINGE UNIV HOSP, DEPT HOSP PHYS, S-14186 HUDDINGE, SWEDEN
关键词
D O I
10.1016/0030-4220(93)90180-C
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The Sens-A-Ray system for direct digital intraoral radiography may be used with any computer compatible with an IBM PC/AT. The system relies on a charge-coupled device designed for direct conversion of x-ray energy to an electronic signal. It is the first such device for direct acquisition of radiographs. Technical properties of charge-coupled device detectors when exposed to radiation energies in the range of x-rays used in dental radiography have been studied. Even in the absence of light or x-radiation there is a spontaneous generation of charge within a charge-coupled device detector that gives rise to a background signal, a dark current. It was found that the dark current is a linear function of exposure time. The dose response of the charge-coupled device detector was determined at nominal kilovoltages that range from 50 to 90 kVp. The dose response was shown to be a linear function of exposure. The functions for all kVp settings were practically identical. The charge-coupled device detector is more sensitive to x-radiation than conventional dental films and, consequently, its exposure range is more narrow. The signal-to-noise ratio was calculated from the digital radiographs used for the dose response test. The ratio is above 1 0 for exposures higher than about 2 muC/kg. The line spread function was determined from test radiographs of a 10 mum wide slit in a test object of 1.5 mm thick tantalum. After curve fitting, the line spread function could be expressed as the sum of a Gaussian and an exponential function. Presampling modulation transfer functions valid at the detector plane and at an object plane were calculated from fitted data on the line spread function. It is concluded that the Sens-A-Ray system has such technical properties that it may replace conventional film-based systems.
引用
下载
收藏
页码:506 / 516
页数:11
相关论文
共 50 条
  • [31] IMAGE QUALITY OF 2 NEW DIRECT DIGITAL INTRAORAL SENSORS
    SANDERINK, GCH
    VERSTEEG, CH
    WELANDER, U
    VANDERSTELT, PF
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 92 - 92
  • [32] Does image file transfer, exposure time and optimization algorithm affect digital intraoral radiographs?
    Grzebieluch, Wojciech
    Kaczmarek, Urszula
    Staniowski, Tomasz
    Mikulewicz, Marcin
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 29 (12): : 1449 - 1458
  • [33] Comparative study of conventional and digital radiographs taken by the intraoral periapical technique in handicapped patients.
    Magalhaes, JCA
    Pereira, MF
    Varoli, OJ
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1167 - 1167
  • [34] Does digital radiography increase the number of intraoral radiographs? A questionnaire study of Dutch dental practices
    Berkhout, WER
    Sanderink, GCH
    Van der Stelt, PF
    DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (02) : 124 - 127
  • [35] Current status on the application of image processing of digital intraoral radiographs amongst general dental practitioners
    Tohidast, Parisa
    Shi, Xie-Qi
    SWEDISH DENTAL JOURNAL, 2016, 40 (02) : 113 - 119
  • [36] Technical parameters to decrease the radiation dose from conventional and digital radiographs
    Foulquier, J. N.
    JOURNAL DE RADIOLOGIE, 2010, 91 (11): : 1225 - 1230
  • [37] A SIMPLE SYSTEM FOR MARKING DIGITAL SUBTRACTION RADIOGRAPHS
    ROWE, GM
    KINGSLEY, DPE
    NEURORADIOLOGY, 1985, 27 (05) : 434 - 435
  • [38] Integrating Facial and Intraoral Scans for Digital Esthetic and Occlusal Design: A Technical Report
    Sun, Ao
    Yang, Yang
    Gao, Hanqi
    Lin, Wei-Shao
    Chen, Li
    Tan, Jianguo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (08): : 729 - 733
  • [39] Digital Workflow to Merge an Intraoral Scan and CBCT of Edentulous Maxilla: A Technical Report
    Carosi, Paolo
    Ferrigno, Nicola
    De Renzi, Giovanni
    Laureti, Mauro
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (08): : 730 - 732
  • [40] Observer agreement in the detection of proximal caries with direct digital intraoral radiography
    Naitoh, M
    Yuasa, H
    Toyama, M
    Shiojima, M
    Nakamura, M
    Ushida, M
    Iida, H
    Hayashi, M
    Ariji, E
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1998, 85 (01): : 107 - 112