Practical considerations in the design and construction of tissue-equivalent proportional counters

被引:17
|
作者
Braby, LA
Johnson, GW
Barthe, J
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a082804
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The design and construction techniques required to produce high quality tissue-equivalent proportional counters are not difficult, but there are a few special considerations. Since there are many options at each stage of the design and construction, and each choice may affect subsequent steps in the process, it is important to consider the entire process. Many successful techniques have been developed by the research groups that have constructed specialised detectors for the requirements of their research. These techniques can generally be extended to the construction of other detectors. Information on design, materials selection, and construction techniques which have proved to be useful in the construction of a wide variety of detectors is presented.
引用
收藏
页码:351 / 379
页数:29
相关论文
共 50 条
  • [21] DOSIMETRY IN MIXED NEUTRON PHOTON FIELDS WITH TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS
    SCHREWE, UJ
    BREDE, HJ
    DIETZE, G
    RADIATION PROTECTION DOSIMETRY, 1989, 29 (1-2) : 41 - 45
  • [22] THE DOSE EQUIVALENT RESPONSE OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS TO LOW-ENERGY NEUTRONS
    SCHUHMACHER, H
    KUNZ, A
    MENZEL, HG
    COYNE, JJ
    SCHWARTZ, RB
    RADIATION PROTECTION DOSIMETRY, 1990, 31 (1-4) : 383 - 387
  • [23] CONSTRUCTION AND TEST OF A PORTABLE TISSUE-EQUIVALENT PROPORTIONAL COUNTER SYSTEM
    Zhang, Weihua
    Ni, Ning
    Wang, Zhiqiang
    Liu, Yina
    Li, Chunjuan
    Luo, Hailong
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (01) : 95 - 100
  • [26] Numerical modeling of the gas gain of low-pressure Tissue-Equivalent Proportional Counters
    Mazzucconi, D.
    Bortot, D.
    Pola, A.
    Agosteo, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 983
  • [27] Lineal Energy Calibration Of Mini Tissue-Equivalent Gas-Proportional Counters (TEPC)
    Conte, V.
    Moro, D.
    Grosswendt, B.
    Colautti, P.
    MULTIDISCIPLINARY APPLICATIONS OF NUCLEAR PHYSICS WITH ION BEAMS (ION BEAMS '12), 2013, 1530 : 171 - 178
  • [28] Microdosimetry studies at the BMRR and the MITR-II using miniature tissue-equivalent proportional counters
    Burmeister, J
    Kota, C
    Maughan, RL
    Riley, K
    Harling, O
    Wielopolski, L
    Ma, R
    Coderre, J
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 581 - 586
  • [29] ON THE CALIBRATION OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS WITH BUILT-IN ALPHA-PARTICLE SOURCES
    SCHREWE, UJ
    BREDE, HJ
    PIHET, P
    MENZEL, HG
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 249 - 252
  • [30] EXPERIMENTAL-STUDY OF THE DOSE EQUIVALENT RESPONSE OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS TO LOW-ENERGY NEUTRONS
    ALBERTS, WG
    BUHLER, G
    DUDLER, R
    MENZEL, HG
    SCHUHMACHER, H
    RADIATION PROTECTION DOSIMETRY, 1984, 9 (03) : 211 - 214