IMPRINTING ZEOLITE-MODIFIED GLASSY CARBON AS A VOLTAMMETRIC SENSOR FOR URIC ACID

被引:7
|
作者
Khasanah, Miratul [1 ]
Harsini, Muji [1 ]
Widati, Alfa Akustia [1 ]
机构
[1] Airlangga Univ, Fac Sci & Technol, Dept Chem, Kampus C Unair, Surabaya 60115, Indonesia
关键词
sensor; uric acid; voltammetry; imprinting zeolite; glassy carbon;
D O I
10.22146/ijc.21292
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Development of the uric acid sensor through coating of glassy carbon ( GC) electrode with imprinting zeolite (IZ) was carried out. Zeolite was synthesized by mixing TEOS, TBOT, TPAOH, and water followed by hydrothermal process. Zeolite was molded together with uric acid to produce IZ. The deposition potential of IZ and uric acid to the GC surface was -0.6 V during 150 sec with addition of KNO3 0.02 M as supporting electrolyte. The method gives linearity of 0.9834 (concentration 5.6x10(-9)M - 2.8x10(-8) M), precision 1.89 - 7.65%, sensitivity 0.33 mu A/nM/cm(2), limit of detection 5.9x10(-9) M, and accuracy 96.26 +/- 0.55% (n = 5). The developed sensor showed a high selectivity toward uric acid. The presence of ascorbic acid, creatine, and creatinine with an equal concentration with uric acid did not interfere on the uric acid analysis.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [1] VOLTAMMETRIC RESPONSE OF ZEOLITE-MODIFIED ELECTRODES
    SHAW, BR
    CREASY, KE
    LANCZYCKI, CJ
    SARGEANT, JA
    TIRHADO, M
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (04) : 869 - 876
  • [2] Accumulation and voltammetric determination of complexed metal ions at zeolite-modified sensor electrodes
    Bing, C
    Kryger, L
    [J]. TALANTA, 1996, 43 (01) : 153 - 160
  • [3] Zeolite-Modified Carbon-Paste Electrode as a Selective Voltammetric Sensor for Detection of Tryptophan in Pharmaceutical Preparations
    Arvand, Majid
    Zanjanchi, Mohammad A.
    Islamnezhad, Akbar
    [J]. ANALYTICAL LETTERS, 2009, 42 (04) : 727 - 738
  • [4] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Dai, Hongxiu
    Wang, Nan
    Wang, Donglei
    Zhang, Xiaomei
    Ma, Houyi
    Lin, Meng
    [J]. MICROCHIMICA ACTA, 2016, 183 (11) : 3053 - 3059
  • [5] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Hongxiu Dai
    Nan Wang
    Donglei Wang
    Xiaomei Zhang
    Houyi Ma
    Meng Lin
    [J]. Microchimica Acta, 2016, 183 : 3053 - 3059
  • [6] Accumulation and voltammetric determination of cobalt at zeolite-modified electrodes
    Ardakani, M. Mazloum
    Akrami, Z.
    Kazemian, H.
    Zare, Hamid R.
    [J]. Journal of Analytical Chemistry, 2008, 63 (02): : 184 - 191
  • [7] Accumulation and voltammetric determination of cobalt at zeolite-modified electrodes
    M. Mazloum Ardakani
    Z. Akrami
    H. Kazemian
    Hamid R. Zare
    [J]. Journal of Analytical Chemistry, 2008, 63 : 184 - 191
  • [8] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 1086 - 1092
  • [9] Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode
    Liu, Ai-Lin
    Zhang, Shao-Bo
    Chen, Wei
    Lin, Xin-Hua
    Xia, Xing-Hua
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (10): : 1488 - 1495
  • [10] Accumulation and voltammetric determination of cobalt at zeolite-modified electrodes
    Mazloum-Ardakani, Mohammad
    Akrami, Z.
    Kazemian, H.
    Zare, Hamid R.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (02) : 184 - 191