ELECTRICAL STRENGTH OF PAPER-OIL INSULATION SUBJECTED TO COMPOSITE VOLTAGES

被引:13
|
作者
MOSINSKI, F
WODZINSKI, J
SIKORSKI, L
ZIENCIKIEWICZ, J
机构
[1] High Voltage Department, Lodz Technical University
关键词
D O I
10.1109/94.311704
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The results of a composite voltage, ac with lightning impulse (LI) tests of a paper-oil insulation model are presented. It was demonstrated that the presence of the background ac voltage leads to a decrease in LI breakdown voltage. This is particularly conspicuous at opposite polarities. The dispersion of LI breakdown voltages decrease save on the case, when the LI is superimposed on the opposite polarities. The dispersion of LI breakdown voltages decrease save on the case, when the LI is superimposed on the opposite polarity peak value of the ac sinusoid. In this critical case the combined breakdown voltage (ac + LI) may be even lower than the ac one.
引用
收藏
页码:615 / 623
页数:9
相关论文
共 50 条
  • [21] Diagnostics of the paper-oil insulation condition using selected parameters of recovery voltage
    Wolny, Stefan
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 214 - 217
  • [22] Modeling of Early Stage Partial Discharge and Overheating Degradation of Paper-oil Insulation
    Tsuchie, Motoo
    Kozako, Masahiro
    Hikita, Masayuki
    Sasaki, Ei
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 1342 - 1349
  • [23] Electrical strength of the oil-paper insulation system at DC and AC voltage
    Kolcunova, Iraida
    Zbojovsky, Jan
    Pavlik, Marek
    Medved', Dusan
    Dolnik, Bystrik
    Bucko, Samuel
    [J]. 2020 21ST INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2020, : 462 - 465
  • [24] Tensile Strength of Resin-Coated Papers and Their Electrical Breakdown Strength in Composite Insulation System with Insulation Oil
    Kurihara, Takashi
    Takahashi, Toshihiro
    Mizutani, Yoshinobu
    Suzuki, Hiroshi
    Okamoto, Tatsuki
    Ogura, Nobuyuki
    Iwamoto, Kazuyoshi
    Kitagawa, Setsuo
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 124 - 124
  • [25] Evaluation via PEA measurements of paper-oil insulation submitted to gamma radiation
    Ciobanu, R.
    Schreiner, C.
    Olariu, M.
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1187 - 1190
  • [27] Near infrared spectroscopy as diagnostic method of moisture content in paper-oil insulation
    Brodka, Boleslaw
    Moscicka-Grzesiak, Hanna
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 136 - 140
  • [28] THE ELECTRICAL BREAKDOWN CHARACTERISTICS OF OIL-PAPER INSULATION UNDER STEEP-FRONT IMPULSE VOLTAGES
    VANDERMAAR, AJ
    WANG, M
    NEILSON, JB
    SRIVASTAVA, KD
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (04) : 1926 - 1935
  • [29] ELECTRIC STRENGTH OF THE INSULATION OF MKS CABLE WHEN SUBJECTED TO PULSE VOLTAGES
    KALININ, ND
    KHABIBULIN, VM
    [J]. TELECOMMUNICATIONS AND RADIO ENGINEERING, 1979, 33-4 (04) : 13 - 16
  • [30] Accelerated Ageing Study of Transformer Paper-oil Insulation under Repetitive Transient Conditions
    Devadiga, A. A.
    Jayaram, S. H.