CALIBRATION OF A LARGE NE213 NEUTRON DETECTOR ARRAY

被引:5
|
作者
OLSSON, N
SODERMAN, PO
NILSSON, L
LAURENT, H
机构
[1] UNIV UPPSALA,DEPT RADIAT SCI,S-75121 UPPSALA,SWEDEN
[2] UNIV UPPSALA,SVEDBERG LAB,S-75121 UPPSALA,SWEDEN
[3] INST PHYS NUCL LYON,F-91406 ORSAY,FRANCE
关键词
D O I
10.1016/0168-9002(94)90625-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast method to calibrate a large neutron detector array, used in neutron decay coincidence experiments, is presented. In the calibration procedure, use is made of the coincidence data collected in a study of neutron decay of excited hole states populated by the Pb-208(He-3,alpha) reaction at an energy of 102 MeV.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 50 条
  • [31] A comparison on three neutron-gamma discrimination methods used with NE213, UGLLT and UGAB scintillators
    Lotfi, Y.
    Moussavi-Zarandi, S. A.
    Ghal-Eh, N.
    Bayat, E.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 171
  • [32] A TECHNIQUE TO OPTIMIZE THE TIME RESOLUTION OF NE213 SCINTILLATION DETECTORS
    NAQVI, AA
    GUL, K
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1991, 16 (04): : 463 - 470
  • [33] Initial operation results of NE213 scintillation detector for time-resolved measurements on triton burnup in KSTAR
    Jo, Jungmin
    Cheon, MunSeong
    Kim, Junghee
    Lim, Soobin
    Isobe, M.
    Ogawa, K.
    Nishitani, T.
    Park, Seugil
    Murata, I.
    Chung, Kyoung-Jae
    Hwang, Y. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [34] THE DEPENDENCE ON SCINTILLATOR SIZE OF THE RESPONSE OF NE213 TO ELECTRONS AND PROTONS
    GALLOWAY, RB
    SAVALOONI, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 199 (03): : 549 - 555
  • [35] NEUTRON DETECTION EFFICIENCY FOR NE213 AND BC501 SCINTILLATORS AT ENERGIES BETWEEN 25 AND 200 MEV
    BYRD, RC
    SAILOR, WC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (03): : 494 - 500
  • [36] THE LIGHT YIELD RESPONSE OF NE213 ORGANIC SCINTILLATORS TO CHARGED-PARTICLES RESULTING FROM NEUTRON INTERACTIONS
    MOUATASSIM, S
    COSTA, GJ
    GUILLAUME, G
    HEUSCH, B
    HUCK, A
    MOSZYNSKI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (03): : 530 - 536
  • [37] NEUTRON MEASUREMENT AND ANALYSIS TECHNIQUES USING AN NE-213-TYPE DETECTOR
    NELSON, ME
    WIGGINS, PF
    RIEL, G
    MILLER, D
    STRICKLER, T
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 47 : 386 - 387
  • [38] Spectrum weighting function method for in-situ fast neutron and gamma-ray response measurements in fusion integral experiments with an NE213 scintillation detector
    Oyama, Yukio
    Sekiyama, Kazunori
    Maekawa, Hiroshi
    Fusion Technology, 1994, 26 (3 pt 2): : 1098 - 1102
  • [39] On timing response improvement of an NE213 scintillator attached to two PMTs
    Zare, S.
    Ghal-Eh, N.
    Bayat, E.
    RADIATION PHYSICS AND CHEMISTRY, 2013, 90 : 6 - 10
  • [40] LIGHT ATTENUATION EFFECTS IN SMALL NE213 SCINTILLATION-COUNTERS
    ANNAND, JRM
    GALLOWAY, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 211 (2-3): : 421 - 427