CALIBRATION OF A LARGE NE213 NEUTRON DETECTOR ARRAY

被引:5
|
作者
OLSSON, N
SODERMAN, PO
NILSSON, L
LAURENT, H
机构
[1] UNIV UPPSALA,DEPT RADIAT SCI,S-75121 UPPSALA,SWEDEN
[2] UNIV UPPSALA,SVEDBERG LAB,S-75121 UPPSALA,SWEDEN
[3] INST PHYS NUCL LYON,F-91406 ORSAY,FRANCE
关键词
D O I
10.1016/0168-9002(94)90625-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast method to calibrate a large neutron detector array, used in neutron decay coincidence experiments, is presented. In the calibration procedure, use is made of the coincidence data collected in a study of neutron decay of excited hole states populated by the Pb-208(He-3,alpha) reaction at an energy of 102 MeV.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 50 条
  • [21] Measurement of neutron-induced proton-production energy spectra with NE213 scintillator
    Kajimoto, Tsuyoshi
    Shigyo, Nobuhiro
    Ishibashi, Kenji
    Arakawa, Hiroyuki
    Haight, Robert C.
    Fotiades, Nikolaos
    RADIATION MEASUREMENTS, 2012, 47 (08) : 596 - 608
  • [22] THE NEUTRON DETECTION EFFICIENCY OF NE213 DETECTORS MEASURED BY MEANS OF A CF-252 SOURCE
    CUB, J
    FINCKH, E
    GEBHARDT, K
    GEISSDORFER, K
    LIN, R
    STRATE, J
    KLEIN, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (1-2): : 217 - 221
  • [23] Neutron spectrometry in mixed fields: NE213/BC501A liquid scintillation spectrometers
    Klein, H
    RADIATION PROTECTION DOSIMETRY, 2003, 107 (1-3) : 95 - 109
  • [25] STUDY OF THE PARAMETERS OF A LONG NE213 SCINTILLATOR COUNTER
    FILCHENKOV, VV
    KONIN, AD
    ZINOV, VG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 245 (2-3): : 490 - 494
  • [26] Neutron-gamma discrimination based on bipolar trapezoidal pulse shaping using FPGAs in NE213
    Esmaeili-sani, Vahid
    Moussavi-zarandi, Ali
    Akbar-ashrafi, Nafiseh
    Boghrati, Behzad
    Afarideh, Hossein
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 694 : 113 - 118
  • [27] FLYSPEC - A SIMPLE METHOD OF UNFOLDING NEUTRON ENERGY-SPECTRA MEASURED WITH NE213 AND STILBENE SPECTROMETERS
    SLAUGHTER, D
    STROUT, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 198 (2-3): : 349 - 355
  • [28] Performance comparison of NE213 detectors for their application in moisture measurement
    Naqvi, AA
    Nagadi, MM
    Rehman, KU
    Kidwai, S
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 745 - 754
  • [29] Neutron measurements on Joint European Torus using an NE213 scintillator with digital pulse shape discrimination
    Esposito, B
    Bertalot, L
    Marocco, D
    Riva, M
    Kaschuck, Y
    Skopintsev, S
    Zimbal, A
    Reginatto, M
    Schuhmacher, H
    Adams, JM
    Murari, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3550 - 3552
  • [30] NE213闪烁体的n-γ分辨
    叶邦角
    Nanjyo H
    Kobayashi T
    Tsuno S
    Hasuko K
    核技术, 2003, (07) : 505 - 508