DELIVERY OF A NEBULIZED AEROSOL TO A LUNG MODEL DURING MECHANICAL VENTILATION - EFFECT OF VENTILATOR SETTINGS AND NEBULIZER TYPE, POSITION, AND VOLUME OF FILL

被引:110
|
作者
ODOHERTY, MJ [1 ]
THOMAS, SHL [1 ]
PAGE, CJ [1 ]
TREACHER, DF [1 ]
NUNAN, TO [1 ]
机构
[1] ST THOMAS HOSP,INTENS CARE UNIT,LONDON SE1 7EH,ENGLAND
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1992年 / 146卷 / 02期
关键词
D O I
10.1164/ajrccm/146.2.383
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Several factors may affect the delivery of a nebulized aerosol to the lung through an endotracheal tube during mechanical ventilation. To study these factors in vitro, a model representing ventilation of an adult patient was constructed by linking a Servo 900C ventilator to a standard humidified circuit and an endotracheal (ET) tube positioned within a pipe representing the trachea. This was connected via a filter to a lung simulator. Nebulizers filled with Tc-99m human serum albumin were positioned in the circuit, and the delivery of nebulized aerosol through the ET tube into the filter was measured using a gamma camera. With the use of an inspiratory phase-activated System 22 Acorn jet nebulizer, typical adult ventilator settings, and a 3-ml nebulizer solution volume, 5.4% of the nebulizer dose reached beyond the end of the ET tube. This was increased by increasing the inspiratory time, reducing the respiratory rate or respiratory minute volume, and by repositioning the nebulizer on the inspiratory limb of the Y-piece and was reduced by slowing the driving gas flow to the nebulizer. Under the same conditions, delivery was 3.1 and 4.4% using the Samsonic and Fisoneb ultrasonic nebulizers, respectively. Increasing the fill volume and the addition of an aerosol storage chamber increased delivery with all three nebulizers. These experiments suggest some simple ways of improving aerosol delivery during mechanical ventilation, including increasing the volume of nebulizer fill, repositioning the nebulizer in the ventilator circuit, adding an aerosol storage chamber, and adjusting ventilator settings to maximize delivery.
引用
收藏
页码:383 / 388
页数:6
相关论文
共 50 条
  • [1] In vitro evaluation of aerosol bronchodilator delivery during noninvasive positive pressure ventilation:: Effect of ventilator settings and nebulizer position
    Chatmongkolchart, S
    Schettino, GPP
    Dillman, C
    Kacmarek, RM
    Hess, DR
    CRITICAL CARE MEDICINE, 2002, 30 (11) : 2515 - 2519
  • [2] Effect of Tidal Volume and Nebulizer Type and Position on Albuterol Delivery in a Pediatric Model of Mechanical Ventilation
    Berlinski, Ariel
    Willis, J. Randy
    RESPIRATORY CARE, 2015, 60 (10) : 1424 - 1430
  • [3] Position of different nebulizer types for aerosol delivery in an adult model of mechanical ventilation
    Hou, Haijia
    Xu, Dongyang
    Dai, Bing
    Zhao, Hongwen
    Wang, Wei
    Kang, Jian
    Tan, Wei
    FRONTIERS IN MEDICINE, 2022, 9
  • [4] EFFECT OF NEBULIZER TYPE AND POSITION ON AEROSOL DRUG DELIVERY DURING SUPPORT MECHANICAL VENTILATION AND SPONTANEOUSLY BREATHING FOR TRACHEOSTOMIZED ADULT PATIENTS
    Kelly, Patrick M.
    O'Sullivan, Andrew
    McKenna, Cathy
    Sweeney, Louise
    MacLoughlin, Ronan
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (04) : A6 - A6
  • [5] Influence of Nebulizer Type, Position, and Bias Flow on Aerosol Drug Delivery in Simulated Pediatric and Adult Lung Models During Mechanical Ventilation
    Ari, Arzu
    Atalay, Orcin Telli
    Harwood, Robert
    Sheard, Meryl M.
    Aljamhan, Essam A.
    Fink, James B.
    RESPIRATORY CARE, 2010, 55 (07) : 845 - 851
  • [6] Placement of the nebulizer before the humidifier during mechanical ventilation: Effect on aerosol delivery
    Moraine, Jean-Jacques
    Truflandier, Karine
    Vandenbergen, Nicolas
    Berre, Jacques
    Melot, Christian
    Vincent, Jean-Louis
    HEART & LUNG, 2009, 38 (05): : 435 - 439
  • [7] DELIVERY OF ULTRASONIC NEBULIZED AEROSOLS TO A LUNG MODEL DURING MECHANICAL VENTILATION
    THOMAS, SHL
    ODOHERTY, MJ
    PAGE, CJ
    TREACHER, DF
    NUNAN, TO
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (04): : 872 - 877
  • [9] EFFECT OF FILL VOLUME ON AEROSOL DELIVERY DURING NON-INVASIVE VENTILATION
    Saeed, Haitham
    Eldin, Abeer Salah
    Elberry, Ahmed A.
    Rabea, Hoda
    Abdelrahim, Mohamed
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (03) : 3 - 3
  • [10] PULMONARY DEPOSITION OF NEBULIZED PENTAMIDINE ISETHIONATE - EFFECT OF NEBULIZER TYPE, DOSE, AND VOLUME OF FILL
    ODOHERTY, M
    THOMAS, S
    PAGE, C
    BRADBEER, C
    NUNAN, T
    BATEMAN, N
    THORAX, 1990, 45 (06) : 460 - 464