Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

被引:0
|
作者
Etemadi, Zahra [1 ,2 ,3 ]
Ghafarian, Pardis [4 ,5 ]
Bitarafan-Rajabi, Ahmad [6 ]
Malek, Hadi [6 ]
Rahmim, Arman [7 ,8 ]
Ay, Mohammad Reza [2 ,3 ]
机构
[1] Shiraz Univ Med Sci, Namazi Teaching Hosp, Nucl Med & Mol Imaging Res Ctr, Shiraz, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Natl Res Inst TB & Lung Dis, Chron Resp Dis Res Ctr, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[6] Iran Univ Med Sci, Rajaei Cardiovasc Med & Res Ctr, Dept Nucl Med, Cardiovasc Intervent Res Ctr, Tehran, Iran
[7] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
[8] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2018年 / 26卷 / 01期
关键词
Cardiac SPECT/CT; Metal artifact reduction; Virtual sonogram; Pacemaker; ICD;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Metallic artifacts due to pacemaker/implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients who underwent myocardial perfusion imaging (MPI). A cardiac phantom with an inserted solid defect was used. The SPECT images were corrected for attenuation using both artifactual CT and CT corrected using metal artifact reduction (MAR). VOI-based analysis was performed in artifactual regions. Results: In phantom studies, mean-of-relative-difference in white-region, between artifact-free attenuation-map without/with MAR were changed from 9.2 and 2.1 to 3.7 and 1.2 for ICD and pacemaker lead, respectively. However, these values for typical patient were 9.7 +/- 7.0 and 3.8 +/- 2.4 for ICD and pacemaker leads respectively, in white-region. MAR effectively reduces the artifacts in white-regions while this reduction is not significant in black-regions. Conclusion: Following application of MAR, visual and quantification analyses revealed that while quality of CT images were significantly improved, the improvements in the SPECT/CT images were not as pronounced or significant. Therefore cardiac SPECT images corrected for attenuation using CT in the presence of metallic-leads can be interpreted without correction for metal artefacts.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 50 条
  • [21] Cardiac SPECT Imaging with Iodine-123 MIBG in Heart Failure Patients Qualified for an Implantable Cardioverter Defibrillator
    Teresinska, A.
    Wozniak, O.
    Maciag, A.
    Wnuk, J.
    Czerwiec, A.
    Jezierski, J.
    Madej, M.
    Biernacka, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S569 - S569
  • [22] Cardiac magnetic resonance imaging in a patient with implantable cardioverter-defibrillator
    Roguin, A
    Donahue, JK
    Bomma, CS
    Bluemke, DA
    Halperin, HR
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (04): : 336 - 338
  • [23] Extraction of pacemaker and implantable cardioverter defibrillator leads: a single-centre study of electrosurgical and laser extraction
    Scott, Paul A.
    Chow, Whitney
    Ellis, Elizabeth
    Morgan, John M.
    Roberts, Paul R.
    EUROPACE, 2009, 11 (11): : 1501 - 1504
  • [24] Extraction of pacemaker and implantable cardioverter defibrillator leads: Patient and lead characteristics in relation to the requirement of extraction tools
    Bracke, F
    Meijer, A
    Van Gelder, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (07): : 1037 - 1040
  • [25] Predictors of Severe Tricuspid Regurgitation in Patients with Permanent Pacemaker or Automatic Implantable Cardioverter-Defibrillator Leads
    Najib, Mohammad Q.
    Vittala, Satya S.
    Challa, Suresh
    Raizada, Amol
    Tondato, Fernando J.
    Lee, Howard R.
    Chaliki, Hari P.
    TEXAS HEART INSTITUTE JOURNAL, 2013, 40 (05) : 529 - 533
  • [26] Sondenextraktion bei Herzschrittmachern und implantierbaren Kardioverter-DefibrillatorenRemoval of pacemaker and implantable cardioverter defibrillator leads
    A. Siebel
    M. Mandewirth
    N. Heinz
    A. Diegeler
    Zeitschrift für Herz-,Thorax- und Gefäßchirurgie, 2015, 29 (6) : 364 - 370
  • [27] Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads
    Lin, G
    Nishimura, RA
    Connolly, HM
    Dearani, JA
    Sundt, TM
    Hayes, DL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (10) : 1672 - 1675
  • [28] Cardiotoxic effects of chemotherapy on cardiac conduction system leading to pacemaker or implantable cardioverter defibrillator implantation
    Zimba, A.
    Rauscha, F.
    Andreas, M.
    Khazen, C.
    Laufer, G.
    Maurer, G.
    Bergler-Klein, J.
    Pavone-Gyoengyoesi, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 : S31 - S31
  • [29] Cardiotoxic effects of chemotherapy on cardiac conduction system leading to pacemaker or implantable cardioverter defibrillator implantation
    Zimba, A.
    Rauscha, F.
    Andreas, M.
    Khazen, C.
    Laufer, G.
    Maurer, G.
    Bergler-Klein, J.
    Pavone-Gyoengyoesi, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (SUPPL 1) : S31 - S31
  • [30] Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT
    McQuaid, Sarah J.
    Hutton, Brian F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) : 1117 - 1123