DISPLAY EQUALIZATION - A NEW DISPLAY METHOD FOR PORTAL IMAGES

被引:14
|
作者
MOSELEY, J
MUNRO, P
机构
[1] UNIV WESTERN ONTARIO,DEPT ONCOL,LONDON N6A 3K7,ONTARIO,CANADA
[2] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON N6A 3K7,ONTARIO,CANADA
关键词
IMAGE DISPLAY; PORTAL IMAGING; TV CAMERA; RADIATION THERAPY;
D O I
10.1118/1.597067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method of displaying portal images which permits the user to optimize the display contrast (windowing and leveling) without clipping parts of the image has been developed. The method finds the average signal (brightness) in small regions of the image, generally 1/64th of the total image area. The difference between the average signal in each small region and the global average over the entire image is subtracted from the original image. This eliminates changes in average signal that occur over large spatial dimensions, such as those due to varying patient thickness, without obscuring changes in signal that occur over small spatial dimensions, such as those due to anatomic structures. The technique is conceptually simple, does not introduce any visually distracting noise into the image, and is not computationally intensive. The display method has been shown to work well with images acquired from a TV camera-based imaging system used in radiation therapy.
引用
收藏
页码:99 / 102
页数:4
相关论文
共 50 条
  • [41] Polarization multiplexing for double images display
    Jinying Guo
    Teng Wang
    Baogang Quan
    Huan Zhao
    Changzhi Gu
    Junjie Li
    Xinke Wang
    Guohai Situ
    Yan Zhang
    Opto-Electronic Advances, 2019, 2 (07) : 4 - 9
  • [42] ALIASING AND QUANTIZATION IN EFFICIENT DISPLAY OF IMAGES
    ALLEBACH, JP
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1977, 67 (10) : 1416 - 1417
  • [43] VIEWPOINT ADAPTIVE DISPLAY OF HDR IMAGES
    Forchhammer, Soren
    Mantel, Claire
    2017 24TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2017, : 1177 - 1181
  • [44] PROBLEMS IN THE OPTIMUM DISPLAY OF SPECT IMAGES
    FIELDING, SL
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1988, 19 (02): : 60 - &
  • [45] OPTIMIZED DISPLAY OF DIGITIZED SCINTIGRAPHIC IMAGES
    CORMACK, J
    HUTTON, BF
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1979, 9 (05): : 624 - 625
  • [46] A DISPLAY AND STORAGE SYSTEM FOR RADIONUCLIDE IMAGES
    LANGAN, JK
    WAGNER, HN
    RADIOLOGY, 1969, 93 (05) : 1197 - &
  • [47] Measurements of static noise in display images
    Roberts, JW
    Kelley, EF
    FLAT PANEL DISPLAY TECHNOLOGY AND DISPLAY METROLOGY II, 2001, 4295 : 211 - 218
  • [48] DISPLAY PROCESSING OF COMPUTED TOMOGRAPHY IMAGES
    FREI, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (02) : 939 - 943
  • [49] Adaptation of document images to display constraints
    Berkner, Kathrin
    Erol, Berna
    HUMAN VISION AND ELECTRONIC IMAGING XIII, 2008, 6806