Measurements of static noise in display images

被引:1
|
作者
Roberts, JW [1 ]
Kelley, EF [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
关键词
array-device measurements; CCD measurements; display measurements; display metrology; narrow-frustum probe; image noise measurements; stray light control; stray-light-elimination tubes; frustums; veiling glare;
D O I
10.1117/12.424874
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The appearance of noise on a display is an important usability issue. Sources of noise include electrical interference, display driver artifacts, resampling artifacts, transmission artifacts, compression artifacts, and any intrinsic noise artifacts produced within a display device. Issues for the severity of the noise problem include total magnitude of noise, noise spatial frequencies, proximity of the noise spatial frequencies to the spatial frequencies of the desired information content and the human-eye response to that information content, uniformity of the distribution of noise, and appearance of any visible or regular patterns in the noise. Whatever the source, an accurate method to measure noise may be required to properly assess the influence of the noise. We investigate the intricacies of using a digital camera to accurately measure noise in a static image on a flat panel display (FPD). The electro-optical transfer function of the FPD is measured. A known noise pattern is displayed and measured using the digital camera whereby the predicted noise is compared to the measured noise. Complications and limitations in the metrology will be discussed.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 50 条
  • [1] ELECTRICAL STORAGE TUBE DISPLAY SYSTEM FOR STATIC AND DYNAMIC IMAGES
    BRILL, AB
    PARKER, J
    PATTON, J
    RICHARDSON, P
    ERICKSON, J
    SOUTHERN MEDICAL JOURNAL, 1972, 65 (11) : 1405 - +
  • [2] Hypoxia Quantification in Static PET Images: The Signal in the Noise
    Keller, H.
    Kueng, R.
    Shek, T.
    Driscoll, B.
    Yeung, I.
    Milosevic, M.
    Jaffray, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3846 - 3846
  • [3] A high frame rate display system for brief presentation of static images
    Kaur, M
    Wilder, J
    Hung, G
    MACHINE VISION SYSTEMS FOR INSPECTION AND METROLOGY VII, 1998, 3521 : 359 - 365
  • [4] Study of Organic Material FETs by Combined Static and Noise Measurements
    Xu Yong
    Minari, Takeo
    Tsukagoshi, Kazuhito
    Bock, Karlheinz
    Fadlallah, Mooness
    Ghibaudo, Gerard
    Chroboczek, J. A.
    NOISE AND FLUCTUATIONS, 2009, 1129 : 163 - +
  • [5] SWEEPING DEVICE WITH VISUAL-DISPLAY FOR NOISE-FIGURE MEASUREMENTS
    HOPF, J
    LINDENMEIER, H
    FREQUENZ, 1977, 31 (12) : 369 - 375
  • [6] CINE DISPLAY OF NUMEROUS STATIC ULTRASOUND IMAGES - A STEP TOWARD AUTOMATION OF ULTRASOUND STUDIES
    DOUST, BD
    BERLAND, LL
    RADIOLOGY, 1980, 136 (01) : 227 - 228
  • [7] TRACKING A STATIC DISPLAY
    MORAY, N
    SYNNOCK, G
    RICHARDS, S
    IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1973, SMC3 (05): : 518 - 521
  • [8] Core asymmetry evaluation using static measurements and neutron noise analysis
    Adorján, F
    Czibók, T
    Kiss, S
    Krinizs, K
    Végh, J
    ANNALS OF NUCLEAR ENERGY, 2000, 27 (07) : 649 - 658
  • [9] RELATIONSHIP BETWEEN STATIC, FLIGHT, AND SIMULATED FLIGHT JET NOISE MEASUREMENTS
    MCGOWAN, RS
    LARSON, RS
    AIAA JOURNAL, 1984, 22 (04) : 460 - 464
  • [10] LIVER VOLUME MEASUREMENTS AND 3-DIMENSIONAL DISPLAY FROM MR IMAGES
    MCNEAL, GR
    MAYNARD, WH
    BRANCH, RA
    POWERS, TA
    ARNS, PA
    GUNTER, K
    FITZPATRICK, JM
    PARTAIN, CL
    RADIOLOGY, 1988, 169 (03) : 851 - 854