Non-Newtonian Arterial Blood Flow through an Overlapping Stenosis

被引:0
|
作者
Srivastava, V. P. [1 ]
Mishra, Shailesh [1 ]
Rastogi, Rati [2 ]
机构
[1] Krishna Girls Engn Coll, Dept Math, Kanpur 209217, Uttar Pradesh, India
[2] SVN Inst Engn Res & Technol, Dept Math, Barabanki 225003, India
关键词
Casson fluid; Impedance; Shear stress; Stenosis throats; Stenosis critical height;
D O I
暂无
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
The effects of an overlapping stenosis on blood flow characteristics in a narrow artery have been investigated. To account for the non-Newtonian behavior, blood has been represented by a Casson fluid. The equation describing the flow has been solved and the expressions for the flow characteristics, namely, the impedance, the wall shear stress, the shear stress at the stenosis throats and the shear stress at the critical height of the stenosis have been derived. It is shown that the impedance increases with the non-Newtonian behavior of blood as well as with the stenosis size. The shear stress at the stenosis two throats assumes the same magnitude. The shear stress at the stenosis critical height assumes significantly lower magnitude than its corresponding value at the throats. With respect to any given parameter, the nature of the variations of shear stresses at the throats and at the critical height of the stenosis is similar to that of the flow resistance.
引用
收藏
页码:225 / 238
页数:14
相关论文
共 50 条
  • [41] Modeling Blood Flow Through Intracranial Aneurysms: A Comparison of Newtonian and Non-Newtonian Viscosity
    Carty, Gregory
    Chatpun, Surapong
    Espino, Daniel M.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (03) : 396 - 409
  • [42] Comparative Study of Newtonian and Non-Newtonian Blood Flow through a Stenosed Carotid Artery
    Rahman, Mohammad Matiur
    Hossain, Md. Anwar
    Mamun, Khairuzzaman
    Akhter, Most. Nasrin
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2017), 2018, 1980
  • [43] Modeling Blood Flow Through Intracranial Aneurysms: A Comparison of Newtonian and Non-Newtonian Viscosity
    Gregory Carty
    Surapong Chatpun
    Daniel M. Espino
    Journal of Medical and Biological Engineering, 2016, 36 : 396 - 409
  • [44] Influence of non-Newtonian blood flow models on drug deposition in the arterial wall
    Gudino, Elias
    Oishi, Cassio M.
    Sequeira, Adelia
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2019, 274
  • [45] Leveraging elasticity of blood stenosis to detect the role of a non-Newtonian flow midst an arterial tube: Mazumdar and Keller models
    Awad, A. M.
    Mekheimer, Kh. S.
    Elkilany, S. A.
    Zaher, A. Z.
    CHINESE JOURNAL OF PHYSICS, 2022, 77 : 2520 - 2540
  • [46] Study of Non-Newtonian Blood Flow Through Arteries Using Openfoam
    Suresh, Arjun
    Rajan, Vikas
    INTERNATIONAL CONFERENCE ON APPLIED MECHANICS AND OPTIMISATION (ICAMEO-2019), 2019, 2134
  • [47] PHYSIOLOGICAL NON-NEWTONIAN BLOOD FLOW THROUGH SINGLE STENOSED ARTERY
    Mamun, Khairuzzaman
    Ali, Mohammad
    Akhter, Most. Nasrin
    THEORETICAL AND APPLIED MECHANICS, 2016, 43 (01) : 99 - 115
  • [48] Effect of non-Newtonian property of blood on flow through a stenosed tube
    Ishikawa, T
    Guimaraes, LFR
    Oshima, S
    Yamane, R
    FLUID DYNAMICS RESEARCH, 1998, 22 (05) : 251 - 264
  • [49] Physiological Non-Newtonian Blood Flow through Single Stenosed Artery
    Mamun, Khairuzzaman
    Rahman, Mohammad Matiur
    Akhter, Most. Nasrin
    Ali, Mohammad
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2015), 2016, 1754
  • [50] Newtonian and non-Newtonian blood flow in coiled cerebral aneurysms
    Morales, Hernan G.
    Larrabide, Ignacio
    Geers, Arjan J.
    Aguilar, Martha L.
    Frangi, Alejandro F.
    JOURNAL OF BIOMECHANICS, 2013, 46 (13) : 2158 - 2164