Effect of non-Newtonian property of blood on flow through a stenosed tube

被引:31
|
作者
Ishikawa, T [1 ]
Guimaraes, LFR [1 ]
Oshima, S [1 ]
Yamane, R [1 ]
机构
[1] Tokyo Inst Technol, Dept Engn Sci & Mech, Meguro Ku, Tokyo 152, Japan
关键词
fluid dynamics; bio-fluid dynamics; non-Newtonian fluid; stenosis; pulsatile flows; numerical analysis;
D O I
10.1016/S0169-5983(97)00041-5
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
It is well known that the fluid dynamics of arterial blood flow plays an important role in arterial diseases. Periodic blood flow through a stenosed tube was analyzed numerically. The bi-viscosity model is used as a constitutive equation for blood, and the flow is assumed to be periodic, incompressible and axisymmetric. Effects of pulsation and the rheological property of blood are considered. The flow pattern, separated region and the distributions of pressure and shear stress at the wall are obtained. The results show that the non-Newtonian property reduces the strength of the vortex downstream of stenosis and has considerable influence on the flow even at high Stokes and Reynolds numbers, provided that pulsatile flow has a stagnant period. (C) 1998 The Japan Society of Fluid Mechanics Incorporated and Elsevier Science B.V. All rights reserved.
引用
收藏
页码:251 / 264
页数:14
相关论文
共 50 条
  • [1] Physiological Non-Newtonian Blood Flow through Single Stenosed Artery
    Mamun, Khairuzzaman
    Rahman, Mohammad Matiur
    Akhter, Most. Nasrin
    Ali, Mohammad
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2015), 2016, 1754
  • [2] PHYSIOLOGICAL NON-NEWTONIAN BLOOD FLOW THROUGH SINGLE STENOSED ARTERY
    Mamun, Khairuzzaman
    Ali, Mohammad
    Akhter, Most. Nasrin
    THEORETICAL AND APPLIED MECHANICS, 2016, 43 (01) : 99 - 115
  • [3] Comparative Study of Newtonian and Non-Newtonian Blood Flow through a Stenosed Carotid Artery
    Rahman, Mohammad Matiur
    Hossain, Md. Anwar
    Mamun, Khairuzzaman
    Akhter, Most. Nasrin
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2017), 2018, 1980
  • [4] Modeling of unsteady non-Newtonian blood flow through a stenosed artery: with nanoparticles
    Zaman, A.
    Khan, Ambreen Afsar
    Ali, N.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (06)
  • [5] Modeling of unsteady non-Newtonian blood flow through a stenosed artery: with nanoparticles
    A. Zaman
    Ambreen Afsar Khan
    N. Ali
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2018, 40
  • [6] Non-Newtonian Flow of Blood in a Catheterized Bifurcated Stenosed Artery
    Misra, Jagadis Chandra
    Shit, Gopal Chandra
    Pramanik, Ranjan
    JOURNAL OF BIONIC ENGINEERING, 2018, 15 (01) : 173 - 184
  • [7] Non-Newtonian flow of blood in a catheterized bifurcated stenosed artery
    Jagadis Chandra Misra
    Gopal Chandra Shit
    Ranjan Pramanik
    Journal of Bionic Engineering, 2018, 15 : 173 - 184
  • [8] Unsteady non-Newtonian blood flow through a tapered overlapping stenosed catheterized vessel
    Ali, N.
    Zaman, A.
    Sajid, M.
    Nieto, J. J.
    Torres, A.
    MATHEMATICAL BIOSCIENCES, 2015, 269 : 94 - 103
  • [9] Unsteady response of non-Newtonian blood flow through a stenosed artery in magnetic field
    Ikbal, Md. A.
    Chakravarty, S.
    Wong, Kelvin K. L.
    Mazumdar, J.
    Mandal, P. K.
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2009, 230 (01) : 243 - 259
  • [10] Role of slip velocity in blood flow through stenosed arteries: A non-Newtonian model
    Misra, J. C.
    Shit, G. C.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2007, 7 (03) : 337 - 353