EXPERIMENTAL-DETERMINATION OF WALL CORRECTION FACTORS .1. CYLINDRICAL IONIZATION CHAMBERS

被引:6
|
作者
WITTKAMPER, FW
MIJNHEER, BJ
机构
[1] Dept. of Radiotherapy, Netherlands Cancer Inst., Amsterdam
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1990年 / 35卷 / 07期
关键词
D O I
10.1088/0031-9155/35/7/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wall correction factors were measured for different types of ionisation chamber. The procedure was to compare the reading of an unknown chamber with that of a reference chamber (graphite Farmer chamber with graphite build-up cap), both in air in a 60Co gamma-ray beam and in a water phantom irradiated by a 20 MeV electron beam. A comparison of the authors' values with other experimental values shows good agreement, within 0.3%, after normalisation on the reference chamber values, for most chambers. However, a 0.9% lower value was observed for a nylon-walled Farmer chamber suggesting that differences in thickness of the inner surface of the thimble might occur. The use of such an inhomogeneous ionisation chamber as a reference instrument for absorbed dose determinations at the reference point in a phantom should therefore not be recommended. Generally good agreement, within 0.5%, exists between experimental and calculated wall correction factors.
引用
收藏
页码:835 / 846
页数:12
相关论文
共 50 条
  • [1] EXPERIMENTAL-DETERMINATION OF WALL CORRECTION FACTORS .2. NACP AND MARKUS PLANE-PARALLEL IONIZATION CHAMBERS
    WITTKAMPER, FW
    AALBERS, AHL
    MIJNHEER, BJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04): : 995 - 1004
  • [2] Wall correction factors and angle dependence of signal currents from cylindrical ionization chambers
    Takata, N
    Kurosawa, T
    Tran, NT
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 743 - 744
  • [3] EXPERIMENTAL-DETERMINATION OF FLUENCE PERTURBATION FACTORS FOR 5 PARALLEL-PLATE IONIZATION CHAMBERS
    KUCHNIR, FT
    REFT, CS
    [J]. MEDICAL PHYSICS, 1993, 20 (02) : 331 - 335
  • [4] Wall correction factors, Pwall, for thimble ionization chambers
    Buckley, LA
    Rogers, DWO
    [J]. MEDICAL PHYSICS, 2006, 33 (02) : 455 - 464
  • [5] DETERMINATION OF REPLACEMENT CORRECTION FACTORS FOR HOMOGENEOUS CYLINDRICAL CHAMBERS
    KUBO, H
    QUADER, MA
    SPACHER, PJ
    [J]. MEDICAL PHYSICS, 1995, 22 (04) : 479 - 480
  • [6] Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method
    Park, Kwangwoo
    Bak, Jino
    Park, Sungho
    Choi, Wonhoon
    Park, Suk Won
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1293 - 1308
  • [7] Experimental determination of magnetic field correction factors for ionization chambers in parallel and perpendicular orientations
    Pojtinger, Stefan
    Nachbar, Marcel
    Ghandour, Sarah
    Pisaturo, Olivier
    Pachoud, Marc
    Kapsch, Ralf-Peter
    Thorwarth, Daniela
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [8] EXPERIMENTAL-DETERMINATION OF THE BEAM QUALITY DEPENDENCE FACTORS, K(Q), FOR IONIZATION CHAMBERS USED IN PHOTON AND ELECTRON DOSIMETRY
    GUERRA, AS
    LAITANO, RF
    PIMPINELLA, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (07): : 1177 - 1190
  • [9] Wall correction factors, Pwall, for parallel-plate ionization chambers
    Buckley, Lesley A.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1788 - 1796
  • [10] Experimental determination of the effective point of measurement and the displacement correction factor for cylindrical ionization chambers in a 6 MV photon beam
    Legrand, C.
    Hartmann, G. H.
    Karger, C. P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21): : 6869 - 6880