Wall correction factors, Pwall, for parallel-plate ionization chambers

被引:42
|
作者
Buckley, Lesley A. [1 ]
Rogers, D. W. O.
机构
[1] Carleton Univ, Ottawa Carleton Inst Phys, Ottawa, ON K1S 5B6, Canada
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Monte Carlo; dosimetry; correction factor;
D O I
10.1118/1.2199988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The EGSnrc Monte Carlo user-code CSnrc is used to calculate wall correction factors, P-wall, for parallel-plate ionization chambers in photon and electron beams. A set Of P-wall values, computed at the reference depth in water, is presented for several commonly used parallel-plate chambers. These values differ from the standard assumption of unity used by dosimetry protocols by up to 1.7% for clinical electron beams. Calculations also show that P-wall is strongly dependent on the depth of measurement and can vary by as much as 6% for a 6 MeV beam in moving from a depth of d(ref) to a depth of R-50, In photon beams, where there is limited information available regarding P-wall for parallel-plate chambers, CSnrc calculations show P-wall values of up to 2.4% at the reference depth over a range of photon energies. The P-wall values for photon beams are in good agreement with previous estimates of the wall correction but have much lower statistical uncertainties and cover a wider range of photon beam energies. (C) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1788 / 1796
页数:9
相关论文
共 50 条
  • [1] Wall correction factors, Pwall, for thimble ionization chambers
    Buckley, LA
    Rogers, DWO
    [J]. MEDICAL PHYSICS, 2006, 33 (02) : 455 - 464
  • [2] CHARGE PROFILES IN PARALLEL-PLATE IONIZATION CHAMBERS
    FERREIRA, GFL
    NUNESDEOLIVEIRA, L
    GROSS, B
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION B-MATHEMATICAL SCIENCES, 1975, 79 (1-2): : 65 - 75
  • [3] SATURATION CHARACTERISTICS OF PARALLEL-PLATE IONIZATION CHAMBERS
    GREENING, JR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1964, 9 (02): : 143 - &
  • [4] SATURATION CURVES OF PARALLEL-PLATE IONIZATION CHAMBERS
    FALLONE, BG
    PODGORSAK, EB
    [J]. MEDICAL PHYSICS, 1983, 10 (02) : 191 - 196
  • [5] SATURATION CURVES OF PARALLEL-PLATE IONIZATION CHAMBERS
    FALLONE, BG
    PODGORSAK, EB
    [J]. MEDICAL PHYSICS, 1983, 10 (04) : 538 - 538
  • [6] ANGULAR-DEPENDENCE OF PARALLEL-PLATE IONIZATION CHAMBERS
    CALDAS, LVE
    ALBUQUERQUE, MDP
    [J]. RADIATION PROTECTION DOSIMETRY, 1991, 37 (01) : 55 - 57
  • [7] SATURATION CURVES OF PARALLEL-PLATE IONIZATION CHAMBERS - COMMENTS
    BOAG, JW
    [J]. MEDICAL PHYSICS, 1984, 11 (01) : 81 - 82
  • [8] SOME CHARACTERISTICS OF GRIDDED PARALLEL-PLATE IONIZATION CHAMBERS
    HERWIG, LO
    MILLER, GH
    UTTERBACK, NG
    [J]. PHYSICAL REVIEW, 1954, 93 (04): : 926 - 926
  • [9] Correction factors for parallel-plate chambers used in plastic phantoms in electron dosimetry
    Nilsson, B
    Montelius, A
    Andreo, P
    Johansson, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11): : 2101 - 2118
  • [10] Beam quality conversion factors for parallel-plate ionization chambers in MV photon beams
    Muir, B. R.
    McEwen, M. R.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2012, 39 (03) : 1618 - 1631