EXPERIMENTAL-DETERMINATION OF WALL CORRECTION FACTORS .2. NACP AND MARKUS PLANE-PARALLEL IONIZATION CHAMBERS

被引:16
|
作者
WITTKAMPER, FW [1 ]
AALBERS, AHL [1 ]
MIJNHEER, BJ [1 ]
机构
[1] NETHERLANDS MEASUREMENTS INST,3720 BA BILTHOVEN,NETHERLANDS
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1992年 / 37卷 / 04期
关键词
D O I
10.1088/0031-9155/37/4/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For pt.I see ibid., vol.35, p.835-46 (1990). The formalism to derive the absorbed dose to water from ionization chamber measurements in a phantom includes several wall correction factors, katt, km and pwall, that depend on the shape, size and composition of the ionization chamber. Wall correction factors have been measured for a number of NACP and PTW/Markus chambers. Significant deviations from calculated values occur due to uncertainties in the contribution to the total ionization from the different materials of these inhomogeneous ionization chambers. Experimental values of pwall larger than one have been obtained for the NACP chamber indicating that the side and back wall material of this chamber reduce the ionization compared with the situation where all electrons originate from the water phantom.
引用
收藏
页码:995 / 1004
页数:10
相关论文
共 43 条
  • [1] CORRECTION FACTORS APPLIED TO PLANE-PARALLEL IONIZATION CHAMBERS
    NYSTROM, H
    KARLSSON, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02): : 311 - 322
  • [2] Wall effects in plane-parallel ionization chambers
    Nilsson, B
    Montelius, A
    Andreo, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (04): : 609 - 623
  • [3] EXPERIMENTAL-DETERMINATION OF WALL CORRECTION FACTORS .1. CYLINDRICAL IONIZATION CHAMBERS
    WITTKAMPER, FW
    MIJNHEER, BJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07): : 835 - 846
  • [4] Monte Carlo determination of electron beam quality correction factors for plane-parallel ionization chambers
    Aldana, J
    Sempau, J
    Mazurier, J
    Andreo, P
    Salvat, C
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S27 - S27
  • [5] Experimental determination of pCo perturbation factors for plane-parallel chambers
    Kapsch, R. P.
    Bruggmoser, G.
    Christ, G.
    Dohm, O. S.
    Hartmann, G. H.
    Schuele, E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23): : 7167 - 7181
  • [6] Wall correction factors for calibration of plane-parallel ionization chambers with high-energy photon beams
    Araki, F
    Ikeda, R
    Shirakawa, Y
    Shimonobou, T
    Moribe, N
    Takada, T
    Takahashi, M
    Oura, H
    Matoba, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2509 - 2517
  • [7] Calibration of plane-parallel chambers and determination of pwall for the NACP and Roos chambers for 60Co γ-ray beams
    Palm, Å
    Mattsson, O
    Andreo, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04): : 971 - 981
  • [8] Monte Carlo calculations of correction factors for plane-parallel ionization chambers in clinical electron dosimetry
    Araki, Fujio
    [J]. MEDICAL PHYSICS, 2008, 35 (09) : 4033 - 4040
  • [10] EXPERIMENTAL-DETERMINATION OF FLUENCE PERTURBATION FACTORS FOR 5 PARALLEL-PLATE IONIZATION CHAMBERS
    KUCHNIR, FT
    REFT, CS
    [J]. MEDICAL PHYSICS, 1993, 20 (02) : 331 - 335