Investigation on the automatic cell counting in feline blood

被引:0
|
作者
Mischke, R [1 ]
Deniz, A [1 ]
Weiss, J [1 ]
机构
[1] SERONO DIAGNOST GMBH,FREIBURG,GERMANY
来源
DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT | 1995年 / 102卷 / 11期
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The usability of the haematology analyzers ''F-800'' and ''System 9000+'' was investigated in cats using 40 blood samples. Reference measurements were done with a haemocytometer or the microhaematocrit method. Reliable leukocyte counts were measured with the analyzer F-800 in cases only, when the histogram rendered possible a clear demarcation of the leukocyte curve (r = 0.97, n = 25). With the analyzer System 9000+ a changed basic adjustment of the inferior discriminator (49 fl) vouched for a close correlation with the values measured visually (r = 0.94). The volume distribution curves of the erythrocytes and thrombocytes which were partly overlapping allowed an approximate counting of the thrombocytes with both analyzers only of one half of the samples, The inaccuracy resulting from the inexact separation had only a relatively unimportant effect on the automatically measured erythrocyte count due to the numerical relation of erythro- and thrombocytes. Hereat a close correlation to the haemocytometer method (r = 0.95) was found as well as slightly higher values with the automatic counting. The haematocrit measured with the analyzer F-800 and to a smaller extent by the use of the System 9000+ lay distinctly higher in relation to the Values measured by microhaematocrit, when the analyzers were calibrated with human standards. Besides a species specific calibration of the haematocrit and a particular basic adjustment for leukocyte counting with the analyzer System 9000+, the use of the investigated haematology analyzers on feline blood requires an individual estimation of the histograms and removing of the discriminators as well as frequently a repetition of the leukocyte- and thrombocyte counting with a haemocytometer.
引用
收藏
页码:435 / 440
页数:6
相关论文
共 50 条
  • [31] Automatic counting of microglial cell activation and its applications
    Beatriz I.Gallego Collado
    Pablo de Gracia
    [J]. Neural Regeneration Research, 2016, 11 (08) : 1212 - 1215
  • [32] Automatic Cell Counting and Labeling for Fluorescence Microscope Images
    Lin, Yuefei
    Diao, Yong
    Zhang, Jianguang
    Li, Ling
    [J]. PROCEEDINGS OF 2019 IEEE 13TH INTERNATIONAL CONFERENCE ON ANTI-COUNTERFEITING, SECURITY, AND IDENTIFICATION (IEEE-ASID'2019), 2019, : 197 - 201
  • [33] A PRELIMINARY INVESTIGATION INTO AUTOMATIC BLOOD GROUPING
    MCNEIL, C
    FERRARI, A
    HELMICK, WM
    [J]. VOX SANGUINIS, 1963, 8 (02) : 235 - +
  • [34] OVERLAPPING WHITE BLOOD CELL SEGMENTATION AND COUNTING ON MICROSCOPIC BLOOD CELL IMAGES
    Fatichah, Chastine
    Purwitasari, Diana
    Hariadi, Victor
    Effendy, Faried
    [J]. INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2014, 7 (03) : 1271 - 1286
  • [36] IMPROVED RED BLOOD CELL COUNTING IN THIN BLOOD SMEARS
    Berge, Heidi
    Taylor, Dale
    Krishnan, Sriram
    Douglas, Tania S.
    [J]. 2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 204 - 207
  • [37] ERRORS IN CONDUCTOMETRIC BLOOD-CELL COUNTING
    BRYSKIN, AI
    PARASHIN, VB
    [J]. MEASUREMENT TECHNIQUES, 1975, 18 (05) : 771 - 774
  • [38] ANALYSIS OF ERRORS IN ELECTRONIC BLOOD CELL COUNTING
    TALSTAD, I
    [J]. ACTA MEDICA SCANDINAVICA, 1971, 190 (1-2): : 1 - +
  • [39] RELIABILITY OF WHITE BLOOD-CELL COUNTING
    LOHMANN, RC
    WOOD, DE
    JACOBS, WI
    ELLIOTT, ML
    [J]. ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1989, 113 (09) : 989 - 994
  • [40] The improved Neubauer ruling for blood cell counting
    Trenner, S
    [J]. JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1924, 10 (1/3): : 0056 - 0058