DOSIMETRY OF I-123 IOMAZENIL IN HUMANS

被引:11
|
作者
VERHOEFF, NPLG
SOKOLE, EB
HENGST, D
STUBBS, JB
VANROYEN, EA
机构
[1] UNIV AMSTERDAM,ACAD MED CTR,DEPT RADIAT SAFETY,1105 AZ AMSTERDAM,NETHERLANDS
[2] OAK RIDGE INST SCI & EDUC,OAK RIDGE,TN
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1993年 / 20卷 / 07期
关键词
DOSIMETRY; I-123; RECEPTORS; BENZODIAZEPINE; FLUMAZENIL; IOMAZENIL;
D O I
10.1007/BF00176551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of I-123-IBZM for adults was estimated to be 0.033 mSv/MBq.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [31] PHARMACOKINETICS OF THE SPECT BENZODIAZEPINE RECEPTOR RADIOLIGAND [I-123] IOMAZENIL IN HUMAN AND NONHUMAN-PRIMATES
    ZOGHBI, SS
    BALDWIN, RM
    SEIBYL, JP
    ALTIKRITI, MS
    ZEAPONCE, Y
    LARUELLE, M
    SYBIRSKA, EH
    WOODS, SW
    GODDARD, AW
    MALISON, RT
    ZIMMERMAN, R
    CHARNEY, DS
    SMITH, EO
    HOFFER, PB
    INNIS, RB
    NUCLEAR MEDICINE AND BIOLOGY, 1992, 19 (08): : 881 - 888
  • [32] Dosimetry of I-123 iododeoxyuridine as a SPECT agent for human glioma.
    Zhang, JJ
    Kim, SM
    Andrews, DW
    Thakur, M
    Intenzo, CM
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 896 - 896
  • [33] THE DOSIMETRY OF N-ISOPROPYL I-123 P-IODOAMPHETAMINE
    ZIMMERMAN, RE
    SHAPIRO, JR
    HOLMAN, BL
    JONES, AG
    KAPLAN, ML
    HILL, TC
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P49 - P49
  • [35] THE KINETICS OF I-123 METAIODOBENZYLGUANIDINE (I-123) IN ADRENERGIC-NEURONS
    SISSON, JC
    GLOWNIAK, JV
    SHAPIRO, B
    MEYERS, L
    MALLETTE, S
    MANGNER, T
    BEIERWALTES, WH
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (2-3): : A27 - A27
  • [36] CENTRAL BENZODIAZEPINE RECEPTOR DISTRIBUTION AFTER SUBCORTICAL HEMORRHAGE EVALUATED BY MEANS OF [I-123] IOMAZENIL AND SPECT
    HATAZAWA, J
    SHIMOSEGAWA, E
    SATOH, T
    KANNO, I
    UEMURA, K
    STROKE, 1995, 26 (12) : 2267 - 2271
  • [37] REVIEW OF PHYSIOLOGICAL PARAMETERS IN DOSIMETRY OF I-123 AND I-131-LABELLED HIPPURAN
    ELLIOTT, AT
    BRITTON, KE
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1978, 29 (9-10): : 571 - 573
  • [38] ROLE OF I-123 IOMAZENIL SPECT IMAGING IN DRUG-RESISTANT EPILEPSY WITH COMPLEX PARTIAL SEIZURES
    SJOHOLM, H
    ROSEN, I
    ELMQVIST, D
    ACTA NEUROLOGICA SCANDINAVICA, 1995, 92 (01): : 41 - 48
  • [39] Mechanism of reduction of cortical blood flow in striatocapsular infarction: Studies using [I-123]Iomazenil SPECT
    Takahashi, W
    Ohnuki, Y
    Ohta, T
    Hamano, H
    Yamamoto, M
    Shinohara, Y
    NEUROIMAGE, 1997, 6 (02) : 75 - 80
  • [40] STANDARDIZATION OF I-123
    REHER, D
    VANINBROUKX, R
    CHAUVENET, B
    MOREL, J
    VATIN, R
    WOODS, M
    LUCAS, S
    BALLAUX, C
    JACQUEMIN, R
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (10): : 923 - 926