Optimization of dental enamel EPR dosimetry spectra measurements parameters

被引:0
|
作者
Zhumadilov, K. Sh [1 ]
Ivannikov, A. I. [2 ]
Stepanenko, V. F. [2 ]
Hoshi, M. [3 ]
机构
[1] LN Gumilyov Eurasian Natl Univ, Astana, Kazakhstan
[2] AF Tsyb Med Radiol Res Ctr, Obninsk, Russia
[3] Hiroshima Univ, Hiroshima, Japan
来源
关键词
EPR dosimetry; tooth enamel; dose of radiation; accumulation time; X-band;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Optimization of parameters for measuring spectra for EPR spectroscopy by tooth enamel was performed with the aim of increasing the accuracy of the method. The uncertainty of the dose determination is directly measured as the mean square deviation of the experimental doses from the nominal doses at different microwave power and the time of measurement of the spectra for ten samples of enamel irradiated in the range from 0 to 500 mGy. The measurements were carried out for the JEOL JES-FA100 spectrometer operating in the X-band and equipped with a cylindrical resonator ES-UCX2 with a high Q factor of the TE011 regime at the University of Hiroshima. Measurements of the samples were carried out at the same measurement parameters, but at different powers of microwave radiation (SHF), as well as for different accumulation times of the spectra. The minimum uncertainty was reached at a microwave power of about 2 mW. To determine the optimal conditions for recording the spectra, direct measurements of the parameters SDS and SDR were carried out. When the total measurement time is set, a lower uncertainty is obtained if we take the average value of the experimental doses obtained from several repeatedly measured spectra after shaking the sample and rotating the tube than from one spectrum recorded at a longer accumulation time.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 50 条
  • [21] SENSITIVITY ENHANCEMENT OF THE TOOTH ENAMEL EPR-DOSIMETRY
    GALTSEV, VE
    GALTSEVA, EV
    GRINBERG, OY
    LEBEDEV, YS
    DOKLADY AKADEMII NAUK, 1994, 334 (05) : 649 - 652
  • [22] Additional criteria for EPR dosimetry using tooth enamel
    EL-Faramawy, N. A.
    Ruehm, W.
    RADIATION RESEARCH, 2007, 167 (02) : 244 - 250
  • [23] Achievable precision and accuracy in EPR dosimetry of tooth enamel
    Haskell, EH
    Hayes, RB
    Kenner, GH
    Wieser, A
    Aragno, D
    Fattibene, P
    Onori, S
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 527 - 535
  • [24] Dental radiography: tooth enamel EPR dose assessment from Rando phantom measurements
    Aragno, D
    Fattibene, P
    Onori, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2671 - 2683
  • [25] Dependencies of the radiation sensitivity of human tooth enamel in EPR dosimetry
    Wieser, A
    El-Faramawy, N
    Meckbach, R
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (05) : 793 - 799
  • [26] The Individual Form of the Background Signal in EPR Dosimetry of Tooth Enamel
    S. V. Dubovskii
    V. A. Kirillov
    Journal of Applied Spectroscopy, 2000, 67 (5) : 878 - 882
  • [27] The technique of EPR-dosimetry with tooth enamel: Achievements and problems.
    Sholom, SV
    Chumak, VV
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C114 - C114
  • [28] Dosimetry study of East Kazakhstan residents by tooth enamel EPR spectroscopy
    Zhumadilov, Kassym
    Ivannikov, Alexander
    Skvortsov, Valeriy
    Stepanenko, Valeriy
    Rakhypbekov, Tolebay
    Hoshi, Masaharu
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [29] EFFECT OF MECHANICALLY INDUCED BACKGROUND SIGNAL ON EPR DOSIMETRY OF TOOTH ENAMEL
    POLYAKOV, V
    HASKELL, E
    KENNER, G
    HUETT, G
    HAYES, R
    RADIATION MEASUREMENTS, 1995, 24 (03) : 249 - 254
  • [30] Q-BAND EPR DOSIMETRY FOR TOOTH ENAMEL BIOPSY SAMPLES
    Misra, Prabhakar
    De, Tania
    Romanyukha, Alexander
    Pass, Barry
    LASERS IN SURGERY AND MEDICINE, 2014, 46 : 57 - 57