The Individual Form of the Background Signal in EPR Dosimetry of Tooth Enamel

被引:1
|
作者
S. V. Dubovskii
V. A. Kirillov
机构
[1] Scientific-Research Clinical Institute of Radiation Medicine and Endocrinology,
关键词
EPR dosimetry; tooth enamel; spectrum modeling; line form;
D O I
10.1023/A:1004172002099
中图分类号
学科分类号
摘要
The dependence of the calculated individual absorbed dose on the form factor, degree of anisotropy, and the model line width of the background component of the EPR spectrum of tooth enamel established. It is shown that an incorrect choice of the model line form for the background component can lead to inadequate evaluation of reconstructed load dose.
引用
收藏
页码:878 / 882
页数:4
相关论文
共 50 条
  • [1] EFFECT OF MECHANICALLY INDUCED BACKGROUND SIGNAL ON EPR DOSIMETRY OF TOOTH ENAMEL
    POLYAKOV, V
    HASKELL, E
    KENNER, G
    HUETT, G
    HAYES, R
    RADIATION MEASUREMENTS, 1995, 24 (03) : 249 - 254
  • [2] EPR dosimetry with tooth enamel: A review
    Fattibene, Paola
    Callens, Freddy
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (11) : 2033 - 2116
  • [3] Elimination of the background signal in tooth enamel samples for EPR-dosimetry by means of physical-chemical treatment
    Ivannikov, AI
    Tikunov, DD
    Skvortsov, VG
    Stepanenko, VF
    Khomichyonok, VV
    Khamidova, LG
    Skripnik, DD
    Bozadjiev, LL
    Hoshi, M
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (05) : 701 - 705
  • [4] Metamorphic modifications and EPR dosimetry in tooth enamel
    Brik, A
    Radchuk, V
    Scherbina, O
    Matyash, M
    Gaver, O
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1317 - 1319
  • [5] Tooth enamel as a detector material for retrospective EPR dosimetry
    Egersdorfer, S
    Wieser, A
    Muller, A
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1299 - 1303
  • [6] EPR-dosimetry with tooth enamel for low doses
    Guettler, Andreas
    Wieser, Albrecht
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 819 - 822
  • [7] Nonlinear Simulation of the Tooth Enamel Spectrum for EPR Dosimetry
    Kirillov, V. A.
    Dubovsky, S. V.
    JOURNAL OF APPLIED SPECTROSCOPY, 2016, 83 (03) : 398 - 405
  • [8] Tooth enamel EPR dosimetry: sources of errors and their correction
    Ivannikov, AI
    Skvortsov, VG
    Stepanenko, VF
    Tsyb, AF
    Khamidova, LG
    Tikunov, DD
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (05) : 1291 - 1296
  • [9] Technique for increasing reproducibility in EPR dosimetry of tooth enamel
    Hayes, RB
    Haskell, EH
    Romanyukha, AA
    Kenner, GH
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (12) : 1994 - 2006
  • [10] Assessment of performance parameters for EPR dosimetry with tooth enamel
    Wieser, A.
    Fattibene, P.
    Shishkina, E. A.
    Ivanov, D. V.
    De Coste, V.
    Guettler, A.
    Onori, S.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 731 - 736