Optimization of dental enamel EPR dosimetry spectra measurements parameters

被引:0
|
作者
Zhumadilov, K. Sh [1 ]
Ivannikov, A. I. [2 ]
Stepanenko, V. F. [2 ]
Hoshi, M. [3 ]
机构
[1] LN Gumilyov Eurasian Natl Univ, Astana, Kazakhstan
[2] AF Tsyb Med Radiol Res Ctr, Obninsk, Russia
[3] Hiroshima Univ, Hiroshima, Japan
来源
关键词
EPR dosimetry; tooth enamel; dose of radiation; accumulation time; X-band;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Optimization of parameters for measuring spectra for EPR spectroscopy by tooth enamel was performed with the aim of increasing the accuracy of the method. The uncertainty of the dose determination is directly measured as the mean square deviation of the experimental doses from the nominal doses at different microwave power and the time of measurement of the spectra for ten samples of enamel irradiated in the range from 0 to 500 mGy. The measurements were carried out for the JEOL JES-FA100 spectrometer operating in the X-band and equipped with a cylindrical resonator ES-UCX2 with a high Q factor of the TE011 regime at the University of Hiroshima. Measurements of the samples were carried out at the same measurement parameters, but at different powers of microwave radiation (SHF), as well as for different accumulation times of the spectra. The minimum uncertainty was reached at a microwave power of about 2 mW. To determine the optimal conditions for recording the spectra, direct measurements of the parameters SDS and SDR were carried out. When the total measurement time is set, a lower uncertainty is obtained if we take the average value of the experimental doses obtained from several repeatedly measured spectra after shaking the sample and rotating the tube than from one spectrum recorded at a longer accumulation time.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 50 条
  • [1] Tooth enamel EPR dosimetry: Optimization of EPR spectra recording parameters and effect of sample mass on spectral sensitivity
    Zhumadilov, K
    Ivannikov, A
    Skvortsov, V
    Stepanenko, V
    Zhumadilov, Z
    Endo, S
    Tanaka, K
    Hoshi, M
    JOURNAL OF RADIATION RESEARCH, 2005, 46 (04) : 435 - 442
  • [2] Epr tooth enamel dosimetry: Optimization of the automated spectra deconvolution routine
    Ivannikov, AI
    Skvortsov, VG
    Stepanenko, VF
    Tikunov, DD
    Takada, J
    Hoshi, M
    HEALTH PHYSICS, 2001, 81 (02): : 124 - 137
  • [3] The Chernobyl accident: EPR dosimetry on dental enamel of children
    Gualtieri, G
    Colacicchi, S
    Sgattoni, R
    Giannoni, M
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (01) : 71 - 79
  • [4] Assessment of performance parameters for EPR dosimetry with tooth enamel
    Wieser, A.
    Fattibene, P.
    Shishkina, E. A.
    Ivanov, D. V.
    De Coste, V.
    Guettler, A.
    Onori, S.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 731 - 736
  • [5] The use of double-integral of experimental EPR spectra for tooth enamel EPR dosimetry
    Tuner, Hasan
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (14) : 1472 - 1476
  • [6] DENTAL ENAMEL EPR DOSIMETRY: COMPARATIVE TESTING OF THE SPECTRA PROCESSING METHODS FOR DETERMINATION OF RADIATION-INDUCED SIGNAL AMPLITUDE
    Ivannikov, A. I.
    Sanin, D.
    Nalapko, M.
    Skvortsov, V. F.
    Stepanenko, V. F.
    Tsyb, A. F.
    Trompier, F.
    Zhumadilov, K.
    Hoshi, M.
    HEALTH PHYSICS, 2010, 98 (02): : 345 - 351
  • [7] EPR dosimetry with tooth enamel: A review
    Fattibene, Paola
    Callens, Freddy
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (11) : 2033 - 2116
  • [8] Signal processing for radiation dosimetry using EPR in dental enamel: comparison of three methods
    Pass, B
    Shames, AI
    RADIATION MEASUREMENTS, 2000, 32 (03) : 163 - 167
  • [9] Metamorphic modifications and EPR dosimetry in tooth enamel
    Brik, A
    Radchuk, V
    Scherbina, O
    Matyash, M
    Gaver, O
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1317 - 1319
  • [10] Feasibility of Q-Band EPR Dosimetry in Biopsy Samples of Dental Enamel, Dentine and Bone
    De, Tania
    Romanyukha, Alex
    Trompier, Francois
    Pass, Barry
    Misra, Prabhakar
    APPLIED MAGNETIC RESONANCE, 2013, 44 (03) : 375 - 387