The use of double-integral of experimental EPR spectra for tooth enamel EPR dosimetry

被引:0
|
作者
Tuner, Hasan [1 ]
机构
[1] Balikesir Univ, Fac Art & Sci, Dept Phys, TR-10145 Balikesir, Turkiye
关键词
PART; 1;
D O I
10.1093/rpd/ncad017
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The presence of background signal in tooth enamel EPR dosimetry is the most challenging situation to overcome. This becomes even more important because it obscures the radiation-induced signal, especially at radiation doses below 1 Gy. In order to overcome this problem, subtraction of the unirradiated sample signal from the irradiated one and the simulation methods are the most widely used methods in the literature. These methods have their own difficulties. Obtaining the double integral of the experimental EPR spectra (first derivative) of tooth enamel and its advantages are presented in the present work. This method offers the opportunity to handle the whole experimental spectrum, both background, and radiation-induced signals, without performing any subtraction or simulation operations, and to overcome the signal-to-noise effects.
引用
收藏
页码:1472 / 1476
页数:5
相关论文
共 50 条
  • [1] EPR dosimetry with tooth enamel: A review
    Fattibene, Paola
    Callens, Freddy
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (11) : 2033 - 2116
  • [2] Epr tooth enamel dosimetry: Optimization of the automated spectra deconvolution routine
    Ivannikov, AI
    Skvortsov, VG
    Stepanenko, VF
    Tikunov, DD
    Takada, J
    Hoshi, M
    HEALTH PHYSICS, 2001, 81 (02): : 124 - 137
  • [3] Metamorphic modifications and EPR dosimetry in tooth enamel
    Brik, A
    Radchuk, V
    Scherbina, O
    Matyash, M
    Gaver, O
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1317 - 1319
  • [4] Tooth enamel EPR dosimetry: Optimization of EPR spectra recording parameters and effect of sample mass on spectral sensitivity
    Zhumadilov, K
    Ivannikov, A
    Skvortsov, V
    Stepanenko, V
    Zhumadilov, Z
    Endo, S
    Tanaka, K
    Hoshi, M
    JOURNAL OF RADIATION RESEARCH, 2005, 46 (04) : 435 - 442
  • [5] Tooth enamel as a detector material for retrospective EPR dosimetry
    Egersdorfer, S
    Wieser, A
    Muller, A
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1299 - 1303
  • [6] EPR-dosimetry with tooth enamel for low doses
    Guettler, Andreas
    Wieser, Albrecht
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 819 - 822
  • [7] Nonlinear Simulation of the Tooth Enamel Spectrum for EPR Dosimetry
    Kirillov, V. A.
    Dubovsky, S. V.
    JOURNAL OF APPLIED SPECTROSCOPY, 2016, 83 (03) : 398 - 405
  • [8] Tooth enamel EPR dosimetry: sources of errors and their correction
    Ivannikov, AI
    Skvortsov, VG
    Stepanenko, VF
    Tsyb, AF
    Khamidova, LG
    Tikunov, DD
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (05) : 1291 - 1296
  • [9] SENSITIVITY ENHANCEMENT OF THE TOOTH ENAMEL EPR-DOSIMETRY
    GALTSEV, VE
    GALTSEVA, EV
    GRINBERG, OY
    LEBEDEV, YS
    DOKLADY AKADEMII NAUK, 1994, 334 (05) : 649 - 652
  • [10] Technique for increasing reproducibility in EPR dosimetry of tooth enamel
    Hayes, RB
    Haskell, EH
    Romanyukha, AA
    Kenner, GH
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (12) : 1994 - 2006