CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER

被引:66
|
作者
AKAMATSU, T [1 ]
NAKAZEKI, T [1 ]
ITOH, H [1 ]
机构
[1] NTN INC,SHIZUOKA,JAPAN
关键词
MAGNETICALLY SUSPENDED CENTRIFUGAL BLOOD PUMP; CENTRIFUGAL PUMP; BLOOD PUMP; MAGNETICALLY SUSPENDED IMPELLER;
D O I
10.1111/j.1525-1594.1992.tb00317.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A centrifugal blood pump with a magnetically suspended impeller has been developed. It has a single inlet and outlet, and it generates centrifugal forces by the rotating impeller. The fluid-dynamical design for inflow and outflow through the impeller leads to elimination of the axial force and unbalanced radial force acting on the impeller. Consequently, three-component control systems, instead of five-component ones, are enough to position the impeller. The magnetically suspended impeller rotates by the magnetic coupling with the permanent magnets embedded in the outer rotator of the motor. This pump has enough performance to function as a blood pump. Further research on the null-power magnetic suspension and the generation of an efficient rotating magnetic field is in progress.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 50 条
  • [31] Flow rate estimation of a centrifugal blood pump using the passively stabilized eccentric position of a magnetically levitated impeller
    Shidai, Shuya
    Masuzawa, Toru
    Osa, Masahiro
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (06): : 291 - 298
  • [32] Effects of Eccentric Impeller Position on Radial Passive Stability in a Magnetically Levitated Centrifugal Blood Pump with a Double Volute
    Shida, Shuya
    Masuzawa, Toru
    Osa, Masahiro
    Sato, Ryota
    [J]. ADVANCED BIOMEDICAL ENGINEERING, 2018, 7 : 63 - 71
  • [33] In vivo and in vitro evaluation of the pulsatile mode of a magnetically suspended centrifugal pump
    Kono, S
    Nishimura, K
    Yamada, T
    Oonishi, T
    Tsukiya, T
    Akamatsu, T
    Ban, T
    [J]. ASAIO JOURNAL, 1997, 43 (05) : M580 - M584
  • [34] A new magnetically suspended centrifugal pump: In vitro and preliminary in vivo assessment
    Park, CH
    Nishimura, K
    Akamatsu, T
    Tsukiya, T
    Matsuda, K
    Ban, T
    [J]. ARTIFICIAL ORGANS, 1996, 20 (02) : 128 - 131
  • [35] Effects of blade geometry on centrifugal blood pump impeller performance
    Chan, WK
    Ng, BTH
    Yu, SCM
    Chua, LP
    Wong, YW
    [J]. IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 583 - 584
  • [36] THE EFFECT OF SHEAR STRESS ON THE IMPELLER DESIGN OF CENTRIFUGAL BLOOD PUMP
    Mondee, Kamonwan
    Foojinphan, Nutchanant
    Wannawat, Praemai
    Naiyanetr, Phornphop
    [J]. 2016 9TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2016,
  • [37] Numerical Study of a Centrifugal Blood Pump With Different Impeller Profiles
    Song, Guoliang
    Chua, Leok Poh
    Lim, Tau Meng
    [J]. ASAIO JOURNAL, 2010, 56 (01) : 24 - 29
  • [38] The CentriMag: A new optimized centrifugal blood pump with levitating impeller
    Mueller, JP
    Kuenzli, A
    Reuthebuch, O
    Dasse, K
    Kent, S
    Zuend, G
    Turina, MI
    Lachat, ML
    [J]. HEART SURGERY FORUM, 2004, 7 (05): : E477 - E480
  • [39] Visualization study of the transient flow in the centrifugal blood pump impeller
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    [J]. ASAIO JOURNAL, 2002, 48 (04) : 431 - 436
  • [40] Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump
    Takami, Y
    Nakazawa, T
    Makinouchi, K
    Tayama, E
    Glueck, J
    Benkowski, R
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 686 - 690