AMBIENT DOSE EQUIVALENTS, EFFECTIVE DOSE EQUIVALENTS, AND EFFECTIVE DOSES FOR NEUTRONS FROM 10 TO 20 MEV

被引:0
|
作者
NABELSSI, BK
HERTEL, NE
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Monte Carlo calculations of dose quantities have been performed using the PNL male and female anthropomorphic phantoms for neutrons between 10 and 20 MeV for the AP, PA, L-LAT, R-LAT, and ROT irradiation geometries. The impacts of the new radiation protection quantities recommended by ICRP 60 were explored. Ambient dose equivalents were calculated using both the ICRP 21 and ICRP 60 Q-L relationships. The ambient dose equivalent was found to underestimate the effective dose at all energies under consideration for the AP and PA irradiation geometries. Tabulations including organ dose equivalents are reported.
引用
收藏
页码:153 / 168
页数:16
相关论文
共 50 条
  • [21] ESTIMATIONS OF POPULATION DOSES AND RISK ESTIMATES FROM OCCUPATIONAL EXPOSURES IN JAPAN, 1978 .1. DETERMINATIONS OF ORGAN OR TISSUE DOSES AND EFFECTIVE DOSE EQUIVALENTS
    MARUYAMA, T
    NISHIZAWA, K
    NODA, Y
    TAKEDA, E
    FUKUHISA, K
    FURUYA, Y
    HASHIZUME, T
    JOURNAL OF RADIATION RESEARCH, 1981, 22 (02) : 182 - 203
  • [22] CONSTANTS FOR CALCULATING AMBIENT AND DIRECTIONAL DOSE EQUIVALENTS FROM RADIONUCLIDE POINT SOURCES
    GROENEWALD, WA
    WASSERMAN, HJ
    HEALTH PHYSICS, 1990, 58 (05): : 655 - 658
  • [23] Calculations of equivalent dose and effective dose conversion coefficients for photons from 1 MeV to 10 GeV
    Sato, O
    Iwai, S
    Tanaka, S
    Uehara, T
    Sakamoto, Y
    Yoshizawa, N
    Furihata, S
    RADIATION PROTECTION DOSIMETRY, 1995, 62 (03) : 119 - 130
  • [24] Comparison of different methods of estimating the effective dose and the ambient dose equivalent for neutrons from measured prompt gamma intensities
    Udupi, Ashwini
    Shetty, Pramoda Kumara
    Panikkath, Priyada
    Sarkar, Pradip Kumar
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 993
  • [25] Fluence to effective dose conversion coefficients for neutrons up to 10 TeV
    Ferrari, A
    Pelliccioni, M
    Pillon, M
    RADIATION PROTECTION DOSIMETRY, 1997, 71 (03) : 165 - 173
  • [26] AGE-DEPENDENT EFFECTIVE DOSES FOR NEUTRONS FROM THERMAL TO 18.3 MEV
    YAMAGUCHI, Y
    RADIATION PROTECTION DOSIMETRY, 1994, 55 (04) : 257 - 263
  • [27] ORGAN DOSES AND EFFECTIVE DOSE EQUIVALENT
    WITTMANN, A
    MORHART, A
    BURGER, G
    RADIATION PROTECTION DOSIMETRY, 1985, 12 (02) : 101 - 106
  • [28] Fluence to effective dose conversion coefficients for protons from 5 MeV to 10 TeV
    Ferrari, A
    Pelliccioni, M
    Pillon, M
    RADIATION PROTECTION DOSIMETRY, 1997, 71 (02) : 85 - 91
  • [29] Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents
    Yener, G
    Kücüktas, E
    ANALYST, 1998, 123 (01) : 31 - 34
  • [30] GET 117-2023 state primary standard for absorbed dose, absorbed dose rate, ambient and personal dose equivalents, and ambient and personal dose equivalent rates from neutron radiation
    Sergey G. Fedorov
    Alexander V. Berlyand
    Vladimir A. Berlyand
    Vladimir M. Dyachenko
    Oleg I. Kovalenko
    Measurement Techniques, 2025, 67 (10) : 725 - 733