Preheated composite resin used as a luting agent for indirect restorations: effects on bond strength and resin-dentin interfaces

被引:0
|
作者
Goulart, Marcelo [1 ]
Veleda, Barbara Barges [1 ]
Damin, Deisi [2 ]
Bovi Ambrosano, Glaucia Maria [3 ]
Coelho de Souza, Fabio Herrmann [1 ]
Guilhe Erhardt, Maria Carolina [1 ]
机构
[1] Univ Fed Rio Grande do Sul, Dept Conservat Dent, Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Dept Surg & Orthoped, Porto Alegre, RS, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Social Dent, Piracicaba, SP, Brazil
来源
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to evaluate the effect of preheating composite resins used as luting agents for indirect restorations on microtensile bond strength (pTBS) and adhesive interfaces. Material and methods: Fifty sound extracted third molars were used. Ten experimental groups were formed with three different luting agents: one resin cement (RelyX ARC) and two composite resins (Venus and Z250 XT). The composite resins were tested both at room temperature and when preheated to 64 degrees C. Restoration depth was tested using 2 or 4 mm-height indirect composite resin restorations, previously made on cylindrical molds. Adhesive and luting procedures were done under simulated pulpal pressure. After luting, the teeth were sectioned into beams with a cross-sectional area of 1 mm(2) at the bonded interface, and tested in ten on at 0.5 mm/min. The characteristics of the adhesive interfaces were observed under scanning electron microscopy (SEM). The pTBS data were analyzed using ANOVA and the Tukey test (alpha = 0.05). Results: When luting 2 mm restorations, the composite resin Z250 XT, preheated or at room temperature, achieved significantly higher pTBS than did RelyX ARC. At this depth, Venus did not differ from the resin cement, and with the 4 mm restorations, only preheated Venus presented significantly higher pTBS than RelyX ARC. Preheating the composite resin resulted in thinner luting interfaces, with a more intimate interaction between luting agent and adhesive layer. Conclusion: Preheating composite resin for luting procedures may not improve pTBS, although it could be used to reduce material viscosity and improve restoration setting.
引用
收藏
页码:86 / 97
页数:12
相关论文
共 50 条
  • [21] Composite inlay luting resin bond strength surface treatment effects
    Shortall, AC
    Baylis, RL
    Wilson, HJ
    JOURNAL OF DENTISTRY, 1996, 24 (1-2) : 129 - 135
  • [22] Composite resin vs resin cement for luting of indirect restorations: Comparison of solubility and shrinkage behavior
    Bortolotto, Tissiana
    Guillarme, Davy
    Gutemberg, Daniel
    Veuthey, Jean-Luc
    Krejci, Ivo
    DENTAL MATERIALS JOURNAL, 2013, 32 (05) : 834 - 838
  • [23] Influence of different immediate dentin sealing strategies on bond strength of indirect resin nanoceramic restorations
    Tahoun, Fatma-Alzahraa Mohamed
    Kehela, Hany Abdel-Ghafar
    Nasr, Dina Mohamed
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2024, 132 (03)
  • [24] Effect of saliva contamination on bond strength of resin luting cements to dentin
    Chung, C. W. M.
    Yiu, C. K. Y.
    King, N. M.
    Hiraishi, N.
    Tay, F. R.
    JOURNAL OF DENTISTRY, 2009, 37 (12) : 923 - 931
  • [25] Effect of Surface Preparation on Bond Strength of Resin Luting Cements to Dentin
    Peerzada, F.
    Yiu, C. K. Y.
    Hiraishi, N.
    Tay, F. R.
    King, N. M.
    OPERATIVE DENTISTRY, 2010, 35 (06) : 624 - 633
  • [26] Desensitizers effect: Resin-dentin bond strength and microleakage of amalgams.
    Vargas, MA
    Cobb, DS
    Denehy, GE
    Reinhardt, JW
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 238 - 238
  • [27] Microtensile bond strengths to cavity floor dentin in indirect composite restorations using resin coating
    Frankenberger, Roland
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2007, 19 (01) : 47 - 48
  • [28] Resin-dentin bond strength as related to different surface preparation methods
    Sattabanasuk, Vanthana
    Vachiramon, Viracha
    Qian, Fang
    Armstrong, Steven R.
    JOURNAL OF DENTISTRY, 2007, 35 (06) : 467 - 475
  • [29] Relationship between nanoleakage and microtensile bond strength at the resin-dentin interface
    Guzmán-Armstrong, S
    Armstrong, SR
    Qian, F
    OPERATIVE DENTISTRY, 2003, 28 (01) : 60 - 66
  • [30] Influence of storage conditions on the durability of resin-dentin bond strength.
    Aziz, K.
    Armstrong, S. R.
    Qian, F.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B54 - B54