SILICON DETECTOR SYSTEM FOR HIGH-RATE EXAFS APPLICATIONS

被引:8
|
作者
PULLIA, A [1 ]
KRANER, HW [1 ]
SIDDONS, DP [1 ]
FURENLID, LR [1 ]
BERTUCCIO, G [1 ]
机构
[1] POLITECN MILAN,DIPARTIMENTO ELETTRON & INFORMAZ,I-20133 MILAN,ITALY
关键词
D O I
10.1109/23.467909
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A multichannel silicon pad detector for EXAFS (Extended X-ray Absorption Fine Structure) applications has been designed and built. The X-ray spectroscopic measurements demonstrate that an adequate energy resolution of 230 eV FWHM (corresponding to 27 rms electrons in silicon) can be achieved reliably at -35 degrees C. A resolution of 190 eV FWHM (corresponding to 22 rms electrons) has been obtained from individual pads at -35 degrees C. At room temperature (25 degrees C) an average energy resolution of 380 eV FWHM is achieved and a resolution of 350 eV FWHM (41 rms electrons) is the best performance. A simple cooling system constituted of Pettier cells is sufficient to reduce the reverse currents of the pads and their related shot noise contribution, in order to achieve resolutions better than 300 eV FWHM which is adequate for the EXAFS applications.
引用
收藏
页码:585 / 589
页数:5
相关论文
共 50 条
  • [41] Symbol timing estimation for high-rate WPAN applications
    You, YH
    Hong, DK
    Lee, JY
    Ju, MC
    Won, YJ
    Cho, JW
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2005, E88B (04) : 1710 - 1713
  • [42] High-rate underwater acoustic telemetry with Naval applications
    Blackmon, F
    Jarvis, S
    Morrissey, R
    Lambert, D
    SEA TECHNOLOGY, 1999, 40 (05) : 67 - 70
  • [43] In situ annealing and high-rate silicon epitaxy on porous silicon by mesoplasma process
    Zhang, Sheng
    Lu, Ziyu
    Sheng, Jiang
    Gao, Pingqi
    Yang, Xi
    Wu, Sudong
    Ye, Jichun
    Kambara, Makoto
    APPLIED PHYSICS EXPRESS, 2016, 9 (05)
  • [44] Scalable multiplexed detector system for high-rate telecom-band single-photon detection
    Brida, G.
    Degiovanni, I. P.
    Piacentini, F.
    Schettini, V.
    Polyakov, S. V.
    Migdall, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (11):
  • [45] Background identification system in MEG II experiment based on high-rate scintillation detector with SiPM readout
    Iwai, R.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [46] High-rate synthesis and characterization of brightly luminescent silicon nanoparticles with applications in hybrid materials for photonics and biophotonics
    Swihart, MT
    Li, XG
    He, YQ
    Kirkey, W
    Cartwright, AN
    Sahoo, Y
    Prasad, PN
    NANOCRYSTALS AND ORGANIC AND HYBRID NANOMATERIALS, 2003, 5222 : 108 - 117
  • [47] Development of segmented straws for very high-rate capability coordinate detector
    Davkov, K.
    Davkov, V.
    Geyer, R.
    Gusakov, Yn.
    Kekelidze, G. D.
    Myalkovskiy, V. V.
    Naumann, L.
    Peshekhonov, D. V.
    Peshekhonov, V. D.
    Savenkov, A. A.
    Tikhomirov, V. O.
    Viryasov, K. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 584 (2-3): : 285 - 290
  • [48] FIBER SCINTILLATORS COUPLED TO A MULTIANODE PHOTOMULTIPLIER AS A HIGH-RATE TRACKING DETECTOR
    SALOMON, M
    COOMBES, H
    NISSEN, M
    ROGERS, JG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 525 - 527
  • [49] High-rate coding system for magnetic recording
    He, RS
    Cruz, JR
    IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (06) : 4522 - 4527
  • [50] HIGH-RATE CAMAC ACQUISITION-SYSTEM
    BELSHE, RA
    LEE, MK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 253 (01): : 65 - 72