CALIBRATION STANDARD FOR LASER-DOPPLER PERFUSION MEASUREMENTS

被引:20
|
作者
LIEBERT, A [1 ]
LEAHY, M [1 ]
MANIEWSKI, R [1 ]
机构
[1] UNIV OXFORD,CHURCHILL HOSP,DEPT DERMATOL,OXFORD OX3 7LJ,ENGLAND
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1995年 / 66卷 / 11期
关键词
D O I
10.1063/1.1146145
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The objective of the present study was the development of a new calibration standard for the laser-Doppler perfusion monitors. The beat frequency spectrum obtained from a solution of latex spheres undergoing Brownian motion was compared to that obtained from a porous polyethylene material containing the same solution. The mixture of static and dynamic scattering events in the latter case was expected to produce a spectrum similar to that obtained in the real human tissue. The results obtained demonstrate clearly the difference between the signals recorded from the commonly used motility standard which are the result of multiple Doppler shifting and homodyne mixing, and those generated from our enhanced model which predominantly result from single Doppler shifting and heterodyne mixing. (C) 1995 American Institute of Physics.
引用
收藏
页码:5169 / 5173
页数:5
相关论文
共 50 条
  • [21] SIGNAL-PROCESSING FOR A LASER-DOPPLER BLOOD PERFUSION METER
    KOELINK, MH
    DEMUL, FFM
    LEERKOTTE, B
    GREVE, J
    JENTINK, HW
    GRAAFF, R
    DASSEL, ACM
    AARNOUDSE, JG
    SIGNAL PROCESSING, 1994, 38 (02) : 239 - 252
  • [22] LASER-DOPPLER PERFUSION IMAGING BY DYNAMIC LIGHT-SCATTERING
    WARDELL, K
    JAKOBSSON, A
    NILSSON, GE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (04) : 309 - 319
  • [23] VENOUS CONGESTION AFFECTS THE ACCURACY OF LASER-DOPPLER STUDY OF PERFUSION
    KAO, YJ
    STODDART, AP
    HYATT, J
    YOONG, B
    ANESTHESIA AND ANALGESIA, 1994, 78 (02): : U109 - U109
  • [24] HUMAN BRONCHIAL PERFUSION EVALUATED WITH ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    SUNDSET, A
    HANSEN, G
    HAANAES, OC
    LINE, PD
    KVERNEBO, K
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1993, 13 (03): : 233 - 245
  • [25] LASER-DOPPLER VELOCITY MEASUREMENTS IN LAMINAR DIFFUSION FLAMES
    JAMES, H
    GREEN, PD
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1971, 4 (05) : 738 - &
  • [26] COMPARISON OF LASER-DOPPLER PERFUSION IMAGING, LASER-DOPPLER FLOWMETRY, AND THERMOGRAPHIC IMAGING FOR ASSESSMENT OF BLOOD-FLOW IN HUMAN SKIN
    SEIFALIAN, AM
    STANSBY, G
    JACKSON, A
    HOWELL, K
    HAMILTON, G
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (01): : 65 - 69
  • [27] LASER-DOPPLER VIBROMETER MEASUREMENTS OF ACOUSTIC TO SEISMIC COUPLING
    ARNOTT, WP
    SABATIER, JM
    APPLIED ACOUSTICS, 1990, 30 (04) : 279 - 291
  • [28] Additional error sources for microscopic laser-Doppler measurements
    Rembe, C
    Dräbenstedt, A
    SIXTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2004, 5503 : 446 - 457
  • [29] Laser-Doppler Anemometry Measurements of Turbulent Swirling Wakes
    Schutz, William M.
    Naughton, Jonathan W.
    AIAA JOURNAL, 2024, 62 (03) : 966 - 978
  • [30] Modelling laser-Doppler perfusion flowmetry of iontophoresis diffusion, applied to preeclampsia
    de Mul, F. F. M.
    Blaauw, J.
    Aarnoudse, J. G.
    Smit, A. J.
    Rakhorst, G.
    JOURNAL OF VASCULAR RESEARCH, 2006, 43 : 47 - 47