PRESERVING THE HIGH SOURCE BRIGHTNESS WITH X-RAY-BEAM LINE OPTICS (INVITED)

被引:6
|
作者
BERMAN, LE
机构
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1995年 / 66卷 / 02期
关键词
D O I
10.1063/1.1145790
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A first-order challenge facing developers of x-ray beam line optics at synchrotron sources lies in producing optics that faithfully deliver the brightness of the source, especially in the presence of adverse power loads. Once overcome, continued use of beam line optics in experiments often reveals a second-order challenge, that of preservation of the source brightness over time, especially as conditions such as the storage ring current change. This requires maintaining stability, with beam line optics, of the peaks, widths, and centroid positions of the various parameters that contribute to the brightness, the wavelength, position, and angle distributions of the delivered photon beam. Some ideas on the use of x-ray monochromators, mirrors, apertures, and position-sensitive monitors to sense and stabilize the brightness parameter distributions, as well as methods to avoid or minimize transients in the first place, are presented. Examples based on experiences at the X25 wiggler beam line at the National Synchrotron Light Source are given. © 1995 American Institute of Physics.
引用
收藏
页码:2041 / 2047
页数:7
相关论文
共 50 条
  • [41] EFFECTIVE DEFLECTION OF X-RAY-BEAM BY CURVED MIRROR SURFACES
    SARKISOV, SR
    SARKISOV, ER
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1989, 32 (06) : 1397 - 1400
  • [42] DEVELOPMENT OF A COMPACT HIGH-BRIGHTNESS X-RAY SOURCE
    CHEN, J
    IMASAKI, K
    FUJITA, M
    YAMANAKA, C
    ASAKAWA, M
    NAKAI, S
    ASAKUMA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 341 (1-3): : 346 - 350
  • [43] USE OF CAPILLARY OPTICS AS A BEAM INTENSIFIER FOR A COMPTON X-RAY SOURCE
    TOMPKINS, PA
    ABREU, CC
    CARROLL, FE
    XIAO, QF
    MACDONALD, CA
    MEDICAL PHYSICS, 1994, 21 (11) : 1777 - 1784
  • [44] THE USE OF A PHOTOACOUSTIC DOSIMETER TO MEASURE THE ENERGY FLUENCE OF AN X-RAY-BEAM
    WAGNER, J
    ZIMMERMAN, R
    MASCARENHAS, S
    MEDICAL PHYSICS, 1984, 11 (05) : 746 - 746
  • [45] PRIMARY SPECTRUM ANALYSIS OF A 6-MV X-RAY-BEAM
    DEWYNGAERT, JK
    HUANG, PH
    KASE, KR
    MEDICAL PHYSICS, 1983, 10 (04) : 545 - 545
  • [46] Multilayer-Based Optics for High-Brightness X-ray Sources
    Bajt, S.
    Chapman, H. N.
    Krzywinski, J.
    Nelson, A. J.
    Aquila, A.
    Barthelmess, M.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 46 - 51
  • [47] ENHANCED BRIGHTNESS X-RAY SOURCE
    LESLIE, B
    NEUKERMANS, A
    SIMON, T
    FOSTER, J
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1983, 1 (04): : 1251 - 1256
  • [48] X-RAY-BEAM POSITION MONITOR USING A QUADRANT PIN DIODE
    SOUTHWORTH, SH
    COWAN, PL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 319 (1-3): : 51 - 55
  • [49] NOISE FACTOR OF A POLYENERGETIC X-RAY-BEAM IN COMPUTED-TOMOGRAPHY
    MORGENTHALER, DG
    BROOKS, RA
    TALBERT, AJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (02): : 251 - 259
  • [50] A SIMPLE PHOTOELECTRON X-RAY-BEAM POSITION MONITOR FOR SYNCHROTRON RADIATION
    HEALD, SM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 411 - 412