PRESERVING THE HIGH SOURCE BRIGHTNESS WITH X-RAY-BEAM LINE OPTICS (INVITED)

被引:6
|
作者
BERMAN, LE
机构
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1995年 / 66卷 / 02期
关键词
D O I
10.1063/1.1145790
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A first-order challenge facing developers of x-ray beam line optics at synchrotron sources lies in producing optics that faithfully deliver the brightness of the source, especially in the presence of adverse power loads. Once overcome, continued use of beam line optics in experiments often reveals a second-order challenge, that of preservation of the source brightness over time, especially as conditions such as the storage ring current change. This requires maintaining stability, with beam line optics, of the peaks, widths, and centroid positions of the various parameters that contribute to the brightness, the wavelength, position, and angle distributions of the delivered photon beam. Some ideas on the use of x-ray monochromators, mirrors, apertures, and position-sensitive monitors to sense and stabilize the brightness parameter distributions, as well as methods to avoid or minimize transients in the first place, are presented. Examples based on experiences at the X25 wiggler beam line at the National Synchrotron Light Source are given. © 1995 American Institute of Physics.
引用
收藏
页码:2041 / 2047
页数:7
相关论文
共 50 条
  • [11] ON HOMOGENEITY OF GRAPHITE MONOCHROMATED PRIMARY X-RAY-BEAM
    RUSSAKOV, AA
    KHEIKER, DM
    SAZONOV, GG
    KRISTALLOGRAFIYA, 1990, 35 (05): : 1057 - 1062
  • [12] SOLID-STATE X-RAY-BEAM MONITOR
    RUDD, PJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (02): : 447 - 450
  • [13] HIGH-ENERGY X-RAY-BEAM CHARACTERIZATION USING PHOTONUCLEAR REACTION
    WIELOPOLSKI, L
    REN, XM
    MEDICAL PHYSICS, 1992, 19 (06) : 1435 - 1439
  • [14] PENUMBRAL CHARACTERISTICS OF A 10 MV X-RAY-BEAM
    HO, TK
    PIPMAN, Y
    ROTHENBERG, LN
    MEDICAL PHYSICS, 1984, 11 (03) : 403 - 403
  • [15] REPLACEABLE BE AND AL WINDOWS FOR X-RAY-BEAM LINES
    OVERSLUIZEN, T
    STEFAN, PM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 375 - 380
  • [16] High Harmonic Generation and X-ray Quantum Optics (Invited)
    Fu Yifei
    Zhao Di
    Li Pengbo
    Li, Fuli
    ACTA PHOTONICA SINICA, 2024, 53 (06)
  • [17] EFFECTS OF X-RAY-BEAM EQUALIZATION ON MAMMOGRAPHIC IMAGING
    LAM, KL
    CHAN, HP
    MEDICAL PHYSICS, 1990, 17 (02) : 242 - 249
  • [18] X-RAY-BEAM PROFILE MEASUREMENTS WITH CCD DETECTORS
    ATTAELMANAN, A
    RINDBY, A
    VOGLIS, P
    SHERMEAT, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 82 (03): : 481 - 488
  • [19] THE OPTICS, EMITTANCE, AND BRIGHTNESS OF THE REFLECTED BEAM SPUTTER SOURCE
    WHITE, NR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (1-2): : 1 - 13
  • [20] UHV PHOTOELECTRON X-RAY-BEAM POSITION MONITOR
    JOHNSON, ED
    OVERSLUIZEN, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 427 - 430