Determination of trace boron in steels by prompt gamma-ray activation analysis

被引:0
|
作者
Kim, I. J. [1 ]
Cho, K. H. [1 ]
Paul, R. L. [2 ]
机构
[1] Korea Res Inst Stand & Sci, 209 Gajung Ro, Daejeon 305340, South Korea
[2] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
来源
ANALYTICAL SCIENCE AND TECHNOLOGY | 2009年 / 22卷 / 04期
关键词
Prompt gamma-ray activation analysis; boron; low alloy steel; certified reference material; uncertainty;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A trace amount of boron in steel significantly influences its mechanical and physical properties. A prompt gamma ray activation analysis (PGAA) method is used to measure boron in low alloy steel samples of KRISS 101-01-C21 similar to C26. NIST SRMs of 362, 364, 1761 and 1767 serve as the control standards to validate the measurement method. The measured values of the NIST SRMs are consistent with their certified values within the expected uncertainties, except for that of NIST SRM 362. Experimental uncertainties are evaluated according to the guidelines given by the International Organization for Standardization (ISO). The expanded uncertainties are calculated with a coverage factor of 2, at approximately 95% confidence level. The calculated relative expanded uncertainties of boron mass fractions are between 3% and 7% at the mg/kg level. The results are compared with the results measured by the solvent extraction-inductively coupled optical emission spectrometry (ICP/OES) method.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 50 条
  • [41] Prompt gamma-ray neutron activation analysis of boron using Deuterium–Deuterium (D–D) neutron generator
    K. Bergaoui
    N. Reguigui
    C. K. Gary
    C. Brown
    J. T. Cremer
    J. H. Vainionpaa
    M. A. Piestrup
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 115 - 121
  • [42] Development of a prompt gamma-ray analysis combined with multiple gamma-ray detection
    Toh, Y
    Oshima, A
    Koizumi, A
    Osa, A
    Kimura, A
    [J]. CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2006, 819 : 603 - +
  • [43] Determination of hydrogen in niobium by cold neutron prompt gamma-ray activation analysis and neutron incoherent scattering
    Paul, RL
    Chen-Mayer, HH
    Myneni, GR
    [J]. HYDROGEN IN MATERIALS AND VACUUM SYSTEMS, 2003, 671 : 151 - 161
  • [44] NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS FOR MULTIELEMENT DETERMINATION IN COMPLEX SAMPLES
    FAILEY, MP
    ANDERSON, DL
    ZOLLER, WH
    GORDON, GE
    LINDSTROM, RM
    [J]. ANALYTICAL CHEMISTRY, 1979, 51 (13) : 2209 - 2221
  • [45] Determination of hydrogen in metals, semiconductors, and other materials by cold neutron prompt gamma-ray activation analysis
    Paul, RL
    Lindstrom, RM
    [J]. HYDROGEN IN SEMICONDUCTORS AND METALS, 1998, 513 : 185 - 190
  • [46] Determination of k 0-values for some elements in neutron capture gamma-ray for prompt gamma activation analysis
    Hamid, A.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 291 (03) : 623 - 628
  • [47] Determination of k0-values for some elements in neutron capture gamma-ray for prompt gamma activation analysis
    A. Hamid
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2012, 291 : 623 - 628
  • [48] DETERMINATION OF BORON BY THERMAL NEUTRON CAPTURE GAMMA-RAY ANALYSIS
    GARBRAH, BW
    WHITLEY, JE
    [J]. ANALYTICAL CHEMISTRY, 1967, 39 (03) : 345 - &
  • [49] THE DETERMINATION OF BORON IN BIOLOGICAL-MATERIALS BY NEUTRON-IRRADIATION AND PROMPT GAMMA-RAY SPECTROMETRY
    WARD, NI
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 110 (02): : 633 - 639
  • [50] Decomposition of prompt gamma-ray spectra including the Doppler-broadened peak for boron determination
    Magara, M.
    Yonezawa, C.
    [J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 411 (01): : 130 - 136